background image

 

14 

 

 

NOTE: 

While this generator is running, power is available from either the standard 120 Volt outlet or the 12 Volt DC outlet. Both 120 Volts and 12 

Volts can be simultaneously drawn from this generator. 

Turn on the connected electrical devices beginning with the device with the highest rated wattage requirement and then each additional device with 
the next lower rated wattage requirement. 

 

 

DC Usage 

 

 

 

To Plug Items to the Generator 

 

1.

 

Allow the engine to run for several minutes after starting. 

2.

 

Make sure that the electrical device is switched off prior to plugging it to generator. 

4. Turn on the connected electrical devices beginning with the device with the highest rated wattage requirement and then each additional device 

with the next lower rated wattage requirement. 

SOME NOTES ABOUT POWER CORDS 

 

Long or thin cords require more wattage from a generator to power an electrical device. Figure 6 shows the recommended cords  according to the 
power requirement of the electrical device. When using cords that exceed these specifications, allow for the electrical device to have a slightly 
higher rated wattage requirement. 

 

Device Requirements 

Max. Cord Length (ft) by Wire Gauge 

Amps 

Watts (120V) 

Watts (240V) 

#8 wire 

#10 wire 

#12 wire 

#14 wire 

#16 wire 

2.5 

300 

600 

NR 

1000 

600 

375 

250 

600 

1200 

NR 

500 

300 

200 

125 

7.5 

900 

1800 

NR 

350 

200 

125 

100 

10 

1200 

2400 

NR 

250 

150 

100 

50 

15 

1800 

3600 

NR 

150 

100 

65 

NR 

20 

2400 

4800 

175 

125 

75 

50 

NR 

25 

3000 

6000 

150 

100 

60 

NR 

NR 

30 

3600 

7200 

125 

65 

NR 

NR 

NR 

40 

4800 

9600 

90 

NR 

NR 

NR 

NR 

 

Figure 6 - Maximum Extension Cord Lengths by Power Requirement 

 

 

SWITCHING BETWEEN GASOLINE & PROPANE FUEL 

In order to switch between gasoline and propane fuel, you must turn off the current fuel. For example, if using gasoline and you want to switch to 
propane, turn the gasoline Fuel Petcock to OFF position and let the engine continue to run until it burns off all remaining gasoline fuel in carburetor. 
Then turn the propane tank ON. If using propane and you want to switch to gasoline, turn the propane tank OFF and turn the gas Fuel Petcock ON. 

 

Even though this generator has an overall rated wattage of 1350, do not attempt to draw more than 1100 Watts from the 120 Volt outlet. 
Draws higher than 1100 Watts will damage this generator and void the warranty. 

 

Do not connect 50Hz or 3-phase loads to this generator. 

 

The DC outlet is for charging 12 Volt battery, up to 8 Amps. 
NEVER attempt to jumpstart a car with this generator. 

 

Do not secure the generator with a chain or rope, which would prevent it from being moved in an emergency. 

Содержание GN1750D

Страница 1: ...s manual provides important information on proper operation maintenance Every effort has been made to ensure the accuracy of this manual These instructions are not meant to cover every possible condit...

Страница 2: ...een poweramerica com service and follow the instructions to register online following the instructions to register online Option 2 Fill out the form on the Warranty Card include in the box and return...

Страница 3: ...Generator 11 Step 1 Verify Oil Level 11 Step 2 Verify Gas Level 11 Step 3 Ground the Generator 11 STARTING THE GENERATOR 12 USING THE GENERATOR 13 AC Usage 13 DC Usage 14 SWITCHING BETWEEN GASOLINE P...

Страница 4: ...en to be defective in materials or workmanship under normal use during the ONE 1 YEAR warranty period Warranty repairs or replacements will be made without charge for parts or labor Parts replaced dur...

Страница 5: ...less AND may be present even if you do not see or smell gas Breathing this poison gas can lead to headaches dizziness drowsiness loss of consciousness and eventually death Usage This generator is not...

Страница 6: ...oors where gasoline fumes may reach flames and or sparks ank cap Loosen the cap slowly to relieve pressure in the fuel tank Avoid spilling fuel ank and immediately wipe it up before starting this gene...

Страница 7: ...7 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator...

Страница 8: ...ere are missing items call 1 888 834 4218 Monday Friday 8 AM 5 PM EASTERN Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETAILER Item List DC connector wires for charging 12 Volt autom...

Страница 9: ...RT DOUBLE CHECK THAT THE OIL LEVEL IS COMPLETELY FULL AND ALMOST OVERFLOWING This generator requires engine oil to function Engine oil is a major factor affecting engine performance and service life W...

Страница 10: ...ed with the generator to the Propane Tank then connect the other end to the Gas Inlet Make sure the LPG Propane cylinder is vertical and securely positioned Step 3 Ground the Generator Ground this gen...

Страница 11: ...T Use only fresh UNLEADED gasoline with an octane rating of 87 or higher Never use old and or contaminated gasoline Never use a mixture of oil and gasoline Avoid getting dirt and or water in the fuel...

Страница 12: ...o snap back 7 If the engine fails to start repeat step 6 NOTE After repeated attempts to start the engine consult the troubleshooting guide before attempting again 8 Once the engine has started GRADUA...

Страница 13: ...e rated wattage for the generator A device s rated running wattage should be listed somewhere on the device itself and or in its manual If the wattage specification for a device is not available the w...

Страница 14: ...Gauge Amps Watts 120V Watts 240V 8 wire 10 wire 12 wire 14 wire 16 wire 2 5 300 600 NR 1000 600 375 250 5 600 1200 NR 500 300 200 125 7 5 900 1800 NR 350 200 125 100 10 1200 2400 NR 250 150 100 50 15...

Страница 15: ...eck Clean X Fuel Tank Verify Gas Level X Clean X Figure 7 Recommended maintenance schedule Cleaning Generator Always try to use this generator in a cool dry place If this generator becomes dirty the e...

Страница 16: ...ed every 6 months or for every 100 hours of use or when the oil has become dirty To drain the oil from generator 1 Place a bucket underneath this generator to catch oil as it drains 2 Unscrew the oil...

Страница 17: ...rk plug An E7TC spark plug such as NGK BP6HS is recommended 4 Measure the spark plug electrode gap with a gauge The gap should be 0 020 0 028in 0 5 0 7mm See Figure 9 5 If re using the spark plug use...

Страница 18: ...h No storage procedure required 1 to 2 months Fill with fresh gasoline and add gasoline stablizer 2 months to 1 year Empty the fuel tank See Emptying the Fuel Tank in the Maintenance Care section 1 ye...

Страница 19: ...on Pull the starter You should see a spark Engine will not start Engine will not start Engine will not start Engine runs but there is no electrical output Generator runs but does not support all conne...

Страница 20: ...20 Distributed by Green Power America LLC www Green PowerAmerica com All copyright is reserved by Green Power America LLC...

Отзывы: