© 2012 G Force Automatic Gates All Rights Reserved
Attaching the Arms and Brackets to the Gate
FOR OUTWARD OPENING GATES REFER TO THE SPECIAL INSTRUCTION SHEET
Refer to the “Internal Manual Release” instructions on page 5. Disengage the motor gear by
loosening the internal release bolt and push the DC motor away from the gearing. The motor
drive arm should now be free to rotate by hand.
Move the gate into the closed position manually.
Fit the swing arm assembly to the drive arm. Loosely attach the mechanical latch arm bracket t0
the other end of the swing arm assembly.
Extend the swing arm straight out and mark a position where the mechanical latch arm bracket
touches the gate. Ensure the swing arm is at the end of the slot furthest from the gate motor.
Measure approximately 40mm back towards the gate motor from the marked position and attach
the mechanical latch swing arm bracket or standard gate bracket to the gate at this point.
Tighten the two swing arm bolts with care not to over tighten. Open and close the gate manually
by hand several times to test.
Swing Arm Bolt
The Safety Swing Arm
Assembly should be
installed as shown here
Mechanical Latch Gate Bracket.
Ensure the swing arm is at the
end of the slot furthest from the
gate motor
AG DC2 GATE MOTOR
INSTALLATION AND SET UP
INSTRUCTIONS
Attach the mechanical latch gate bracket ( to the
end of swing arm using brass olive, bolt and nut.
Ensure the bolt is in the slot.
Swing
Arm
Drive Arm
Screw the two 12mm bolts with lock washers
(not shown) to attach Swing Arm to the Drive
Arm.
Swing Arm Bolt