FYTTER |WWW.FYTTER.COM
PAG- 37
11.
COMMON ERRORS / ERRORES COMUNES / ERREURS COMMUNES / GLI ERRORI PIU COMUNI / HÄUFIGE
FEHLER / VEELVOORKOMENDE FOUTEN
Error Code
Reason
No display on the console after
the power is started
The probable reason is that the wire from the console to the bottom control board is
not connected well or the transformer is burnt out. Take off the upright frame tubes
and check every single connection part of the wires from the console to the bottom
control board and make sure that all the wires are connected well. If the problem is
caused by the defective wires or the defective transformer, please do the replacement
by the new wires or transformer.
E01
Communication failure
The probable reason is that the communication from the console to the bottom control
board is stuck. Check every single connection part of the wires from the console to the
bottom control board and make sure that all the wires are connected well. If the
problem is caused by the defective wires, do the replacement by the new wires.
E02
Burst clash protection
Check if the voltage is lower than 50% of the normal voltage and do the testing again by
the correct voltage. Check if the control board has strange smell, if it is, please use a
new control board to do the replacement. Check if the motor wires are connected well,
and re-connect the motor wires well.
E03
No sensor signal
The probable reason is that the speed sensor signal has not been received during 10
seconds, check if the sensor signal light of the bottom control board is flashing, if not,
please use the new part to do the replacement. Check if the sensor plug is connected
well or if the magnetic sensor is broken, re-connect the sensor plug or change the
magnetic sensor with the new one. Check if it DC motor is work well or the motor wire
is connected well. If not, connect it well or change a new motor.
E05
Current overload protection
The probable reason is that the user’s weight is over limit loading and causes too much
current, so the unit starts self-protection system. If a certain part of the treadmill is
stuck, it may also cause the problems that the motor can not rotate, the loading is over
the limit and the current is too much. Adjust the treadmill well and restart the unit
power. In addition, check if the motor has the overloading current sound or the burning
smell, if yes, change the motor by the new one. Check if the control board has the
burning smell, if yes, change the control board by the new one. Check if the voltage is
normal or too low, do re-testing by the correct voltage.
E06
Motor Wire and Control Board
wire connection failure
The probable reason is that the Motor Wire and Control Board wire is not connected
well or the DC motor is open circuit.
If the motor doesn’t rotate
after pressing the START
button
Check if the motor wires are broken, the fuses of the bottom control board are
damaged or come off, the motor wires are connected well, and the IGBT of the bottom
control board is burnt. Check if all the motor wires are connected well, the fuses of the
control board are okay, if not, re-assemble it or change the part with the new one.
Check if the motor is getting loose, and connect the motor wires well. Use the Multi-
meter to test if the IGBT of the bottom control board is burnt out, change either the
IGBT or the whole bottom control board.