FYTTER |
WWW.FYTTER.COM
PAG- 37
11.
COMMON ERRORS / ERRORES COMUNES / ERREURS COMMUNES / GLI ERRORI PIU COMUNI /
HÄUFIGE FEHLER / VEELVOORKOMENDE FOUTEN
Error Code
Reason
How to solve
E-01
Poor connection between the
display and controller.
Check each joint, change a new line if it is
broken.
E-02
Over current protection
Turn off and re-start machine, if still has
problem, need to check motor and pcb if they
are broken
E-03
Over load protection
Turn off and re-start machine, if still has
problem, need to check motor and pcb if they
are broken
E-04
Sudden big current protection
Check running belt or other place if
something inside, or check pcb if it is burnt.
E-05
Explosion proof protection
Check the input voltage is normal or not, or
check pcb burnt or not, or check motor wire
is well connected or not.
E-07
Incline checking failure
Check the AC line in incline motor is well
connected or not, or maybe incline motor
broken, or maybe pcb broken