background image

Model

Input Voltage

Input Power

Curing Area

Temperature

Time Setting

Light Intensity

FY-3DH

220V / 1-ph / 50-60Hz

×

 1000W

1200 

×

 1000mm

35°C - 80°C

0min - 99mins

 

adjustable

10% - 100%

2. SPECIFICATIONS

Page 2

Содержание FY-3DH

Страница 1: ...Instruction Manual FY 3DH Our equipment is approved by the following car manufacturers China ...

Страница 2: ...Contents 1 Precautions 2 Specifications 3 Installation 4 Controls 5 Operation 6 Troubleshooting 1 Troubleshooting 2 Lamp Tube Replacement 7 Exploded View 8 Circuit Diagram 1 2 3 4 5 7 8 9 10 ...

Страница 3: ... qualified installer or service agency 4 The system has been designed for easy installation low operating costs and minimal maintenance The warranty does not cover lamp tube defects resulting from misuse or improper operation 5 Disconnect power source when the equipment is not in use for a long time 6 The light tube should not be perpendicular to the ground when the equipment is in operation Other...

Страница 4: ...Model Input Voltage Input Power Curing Area Temperature Time Setting Light Intensity FY 3DH 220V 1 ph 50 60Hz 3 1000W 1200 1000mm 35 C 80 C 0min 99mins adjustable 10 100 2 SPECIFICATIONS Page 2 ...

Страница 5: ...lumn b Put the column vertically on the top of the base directly engage the screw holes and tighten up using the screws c Connect the support arm with the column for supporting cassette d Connect the lifter with the column to control the up and down movement of cassette 3 Installation of the cassette a Open the packing of the cassette b Connect cassette with support arm and tighten up with the scr...

Страница 6: ...Auto mode 7 Start 8 Stop 4 CONTROLS Page 4 1 Setting for Distance Press and hold the Setting Button 5 to enter into setting mode Set the curing parameters according to the requirements of different paints Nearest distance The equipment will stop automatically when the distance between the panel and emitter is less than its preset distance Farthest distance The equipment will stop automatically whe...

Страница 7: ...Lowest Temperature 35 C 4 Highest Temperature 75 C d Press the Auto button and then press Start to go into the automatic curing mode Once the automatic mode is selected four related cure programs become available to the user Program 1 4 The curing time and power should be set according to the requirements of the paint material d The time and power can not be set directly during the program running...

Страница 8: ...ace is recommended e The curing time and power should be set according to the requirements of the paint material Usually Pulse is set to 5 mins and Routine to 10 mins g Turn off the equipment when the work is completed 3 Pulse Mode a Set power and time Press the button Setting and select Pulse b Press the Start button c The curing distance between the cassette and paint surface should be set accor...

Страница 9: ...tube damaged b Lamp is not plugged in c Control silicon damaged a Control silicon damaged a Unplugged flat wire in circuit board b Digital display damaged a Switch imbalance b Keyboard has exclusion SOLUTION a Check lamp tube b Plug in lamp holder c Check control silicon a Check control silicon a Check flat wire b Check digital display a Check the installation of switch b Check keyboard exclusion ...

Страница 10: ... grille of cassette c Remove the plates from both ends of the cassette d Remove the fixed plates from both ends of the cassette e Loosen fixed screws and cut off connections the lamp can be replaced f Repeat the steps above in reverse order to replace the lamp 6 TROUBLESHOOTING Page 8 ...

Страница 11: ...ting rod Connector Adjustable hand wheel NAME Aluminium handle Clamping bar Side panel Cassette Plastic handle Lower connecting rod NAME Lifter Front wheel U type base Back wheel Cover plate lower Handle NAME Cover plate upper Circuit board Sensor box 1 2 3 4 5 6 11 12 13 14 15 16 17 18 19 20 7 8 9 10 21 7 EXPLODED VIEW ...

Страница 12: ...12345 PCB1 Distance sensor PCB2 Temperature sensor Control Transformer Main switch 20 19 18 17 16 20 19 18 17 16 32 31 30 CND GON DC12V A 1 A 2 Ba 1 B 2 C 1 C 2 Page 10 8 CIRCUIT DIAGRAM ...

Отзывы: