5. OPERATION
Page 5
1. Automatic Mode
a. Properly assemble the curing system according to the instruction (see page 3).
b. Switch on the power supply. The system is ready to use when the graphic appears on the
display screen as follows:
00
:
00
POWER
:
80
%
00CM
00
℃
Routine
Pulse
e. Setting curing time. Press the navigation buttons "time +" or "time -” (Button 4, Page 4)
when the lamp is ready to use to adjust curing time.
f. Protect the lamp against shocks and vibrations when the lamp is in use.
g. After this program is completed, the system is able to carry out other programs. Make
sure to turn off the system when the equipment is not in use and keep the equipment
securely in place.
step1
step2
step3
step4
⸠
(5
min)
Routine
Time
Power
(
70%)
Pulse Time
(
15
min)
Power
(
60%)
Routine
Time
(
5
min)
Power
(
60%)
Pulse Time
(
15
min)
Power
(
60%)
1
.
Nearest
distance (20cm)
2
.
Farthest distance (70cm)
3
.
Lowest Temperature (35°C
)
4
.
Highest
Temperature
(
75
°C
)
d. Press the "Auto" button and then press "Start" to go into the automatic curing mode.
Once the automatic mode is selected, four related cure programs become available to
the user – Program 1-4 . (The curing time and power should be set according
to the requirements of the paint material).
d. The time and power can not be set directly
during the program running.
1.The data can be set before the program started.
2.The data can also be adjusted during program
with a long press on the button “Setting”
changing the interface to set the data.
c. Move the cassette forward or backward from the paint surface to adjust to the best
distance for curing. The distance data will be detected and shown on the display screen
automatically. The measuring range is 20-120cm and beyond it is blind zone. The curing
distance between the cassette and paint surface should be set according to the paint
material and weather conditions (air humidity). Usually, keeping a distance of about
45cm from the paint surface is recommended.