3 s


AUTO

1

2

3

5

6
7

8

4

1. LCD display
2. Lamp selector (each lamp can be controlled 
     separately)
3. Power adjustment
4. Time adjustment
5. Setting:
     - Press the button once, it will enter into 
       "Routine" mode when the lamp is on. 
     - Press again, it will enter into "Pulse" mode 
       when the lamp is on. 
     - Press and hold to enter into curing 
       parameters setting mode.
6. Auto
7. Start
8. Stop

1. Setting for Distance
Press and hold the "Setting" (Button 5) to enter into setting mode. Set the curing parameters 
according to the requirements of different paints. Nearest distance: The equipment will stop 
automatically when the distance between the panel and emitter is less than its preset distance. 
Farthest distance: The equipment will stop automatically when the distance between the panel 
and emitter exceed its preset distance. The equipment works only in the preset distance range.

2. Setting for Temperature
Press "Power adjustment" (Button 3) when the lamp is ready to use to set the temperature.

3. Setting for Automatic Mode
Press "Setting" (Button 5) when the lamp is ready to use to set curing parameters (shown on 
LCD display) according to the requirements of different paints to achieve the best effect - see 
next page.

4. CONTROLS

Page 4

Cir c u i t b r e aker must b e insta l l e d

Содержание FY-3D

Страница 1: ...Instruction Manual Our equipment is approved by the following car manufacturers FY 3D ...

Страница 2: ...CONTENTS 1 Precautions 2 Specifications 3 Installation 4 Controls 5 Operation 6 Troubleshooting 1 Troubleshooting 2 Light Tube Replacement 7 Exploded View 8 Circuit Diagram 1 2 3 4 5 7 8 9 10 ...

Страница 3: ...staller or service agency 4 The system has been designed for easy installation low operating costs and minimal maintenance The warranty does not cover lamp tube defects resulting from misuse or improper operation 5 Disconnect power source when the equipment is not in use for a long time 6 The light tube should not be perpendicular to the ground when the equipment is in operation Otherwise it will ...

Страница 4: ... Input Power Curing Area Temperature Time Setting Light Intensity Curing Distance FY 3D 230V 1 ph 50 60Hz 3 1000W 1200 1000mm 35 C 100 C 0min 99min adjustable 10 100 20cm 120cm 2 SPECIFICATIONS Page 2 1600mm 2050mm 2400mm ...

Страница 5: ...e the screw holes and tighten up using the screws c Connect the support arm with the column for supporting cassette d Connect the lifter with the column to control the up and down movement of cassette 3 Installation of the cassette a Open the packing of the cassette b Connect cassette with support arm and tighten up with the screws c Connect control wires and adjust the angle of cassette 3 INSTALL...

Страница 6: ...top 1 Setting for Distance Press and hold the Setting Button 5 to enter into setting mode Set the curing parameters according to the requirements of different paints Nearest distance The equipment will stop automatically when the distance between the panel and emitter is less than its preset distance Farthest distance The equipment will stop automatically when the distance between the panel and em...

Страница 7: ...m 3 Lowest Temperature 35 C 4 Highest Temperature 7 5 C d Press the Auto button and then press Start to go into the automatic curing mode Once the automatic mode is selected four related cure programs become available to the user Program 1 4 The curing time and power should be set according to the requirements of the paint material d The time and power can not be set directly during the program ru...

Страница 8: ...e set according to the requirements of the paint material Usually Pulse is set to 5 mins and Routine to 10 mins g Turn off the equipment when the work is completed 3 Pulse Mode a Set power and time Press the button Setting and select Pulse b Press the Start button c The curing distance between the cassette and paint surface should be set according to the paint material and weather air humidity Usu...

Страница 9: ...tube damaged b Lamp is not plugged in c Control silicon damaged a Control silicon damaged a Unplugged flat wire in circuit board b Digital display damaged a Switch imbalance b Key board has exclusion SOLUTION a Check light tube b Check the connections c Check control silicon a Check control silicon a Check flat wire b Check digital display a Check the installation of switch b Check keyboard exclus...

Страница 10: ... grille of cassette c Remove the plates from both ends of the cassette d Remove the fixed plates from both ends of the cassette e Loosen fixed screws and cut off connections the light tube can be replaced f Repeat the steps above in reverse order to replace the light tube 6 TROUBLESHOOTING Page 8 ...

Страница 11: ...Cassette NAME Plastic nut Connecting axle Connector right Handle Lower support arm Upper support arm Lifter Lifter handle NAME Front caster U type base Back wheel Cover plate lower Flange Control silicon Handle Power switch NAME Transformer Cover plate upper Circuit board Temperature distancesensor Page 9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 ...

Страница 12: ...ge 10 2 2 0V 0 V G2 K 2 G 1 K 1 K1 G1 K2 G2 G1 G2 K1 K2 AC 230V The L amps 0V 12 V PCB Board 16 17 18 19 20 16 17 18 19 20 Control Silicon Power Switch Transformer Distance Sensor PCB for Distance PCB for Temperature Lamps ...

Отзывы: