FWE MOISTURE-TEMP MTU Series Скачать руководство пользователя страница 7

6

TROUBLE-SHOOTING CHART

Check this list first before you call for service...

PROBLEM           POSSIBLE CAUSE

REMEDY

TEMP

TOO 

HOT

TEMP

NOT 

HOT

ENOUGH

NO HEAT 

AT ALL

1A] Adjustable thermostat 

set too high

1B] Thermostat needs 

re-calibrating**

2A] Opening door unnecessarily

2B] Thermostat set too low
2C] Cord plug pulled out from outlet
2D] Fuse blown - no power to outlet

2E] Thermostat out of calibration**

3A] Cabinet not plugged into outlet
3B] Thermostat knob at “ OFF ”

3C] Rocker switch at “ OFF ” position
3D] Fuse Blown - no power to outlet

3E] Thermostat needs replacing

3F] Heating element burned out*

1A] Set thermostat at a lower temperature 

(no lower than 140°F).

1B] Loosen screw in thermostat knob and remove knob.

Adjust set screw in hollow stem with small blade 

screwdriver by turning CLOCK-WISE. 
1/4 turn lowers temperature approximately 10°F. 
DO NOT REMOVE SET SCREW.

2A] Keep door closed and latched shut 

as much as possible.

2B] Set thermostat at a higher temperature.
2C] Replug cord into proper outlet.
2D] Have a qualified electrician check power 

and fuse box.

2E] Loosen set screw in thermostat knob 

and remove knob. Adjust set screw in hollow stem
with small blade screwdriver by turning 
COUNTER-CLOCKWISE. 
1/4 turn raises temperature approximately 
10°F. DO NOT REMOVE SET SCREW.

3A] Plug cabinet into properly grounded electrical outlet.
3B] Adjust thermostat knob to temperature 

setting required.

3C] Turn switch to “ ON ” position.
3D] Have a qualified electrician check power 

to fuse box.

3E] Unplug cabinet from electrical source. 

Loosen set screw in thermostat knob and remove
knob. Remove control panel, disconnect wires from
terminals on thermostat, and remove 2 screws 
holding thermostat to control panel. Replace
thermostat with new one, and re-install control
panel and thermostat knob.

3F] Unplug cart from electrical source. Remove screws 

holding heating element in place. Gently pull 
element away from back wall a few inches to
expose wire connections. Disconnect wires, and
replace element with new one. Reconnect wires,
secure element with screws.

* * NOTE: CALIBRATION IS EXCLUDED FROM FWE WARRANTY. Thermostats on all units are calibrated at the factory

* * 

prior to shipping. Due to conditions in transit, beyond our control, occasionally units will need to be re-calibrated prior 

* * 

to use. This is a simple procedure for which instructions are given above. (1B, 2E)

* Heating element will either function or not function. Only a slight warmth indicates a problem with the thermostat, 

not the element.

Содержание MOISTURE-TEMP MTU Series

Страница 1: ...MOISTURE TEMP CABINETS OPERATING INSTRUCTIONS Thermometer Air Temperature HEAT Control Dial Air Moisture Control Main Power Switch Heat Cycling Light...

Страница 2: ...12 x 20 Water Pan and Heat Basin Heat System Tunnel Control Panel Moisture Drip Trough With Removable Drain Plug MOISTURE TEMP CABINETS 1 FWE MOISTURE TEMP HEAT SYSTEM Serial Tag and Parts List...

Страница 3: ...for your protection against possible shock hazards Be sure to plug only into a properly grounded three prong wall receptacle If you have any questions with regard to adequate wiring or grounding in yo...

Страница 4: ...TO USE CONTROLS Thermometer Air Temperature HEAT Control Dial Air Moisture Control Dial P to Indicates Proof Position Proof Cycling Light Main Power Switch Heat Cycling Light Press tactile key to alte...

Страница 5: ...tioned into heat basin Amount of water required in pan is determined by start up time length of holding time and level of humidity desired ADJUSTABLE TRAY SLIDES Standard cabinet models are equipped w...

Страница 6: ...3 PRE HEAT THE CABINET by turning the rocker switch to the ON position Allow approximately 15 25 minutes of pre heat time The door should be kept tightly closed during this procedure to obtain the opt...

Страница 7: ...ith small blade screwdriver by turning COUNTER CLOCKWISE 1 4 turn raises temperature approximately 10 F DO NOT REMOVE SET SCREW 3A Plug cabinet into properly grounded electrical outlet 3B Adjust therm...

Страница 8: ...clean by simply wiping the interior and exterior as needed with a damp cloth or sponge and a mild soapy solution NEVER USE ABRASIVES ACIDS OR STRONG CLEANERS Do not flood or allow electrical parts to...

Страница 9: ...sts the amount of humidity in the cabinet from 1 7 A CYCLING light indicates that this function is activated The air temperature control goes from 90 F to 190 F 30 C to 90 C and adjusts the amount of...

Страница 10: ...__________ ___________________________________________________ ___________________________________________________ ___________________________________________________ _________________________________...

Страница 11: ...Environment Facilities which is warranted for a period of six 6 months This warranty is for normal usage and does not apply to any product or parts thereof that have been misused altered or where Sell...

Страница 12: ...anual Moisture Temp Basin Style P O Box 1001 Crystal Lake IL 60039 1001 USA 815 459 7500 Fax 815 459 7989 FWE Parts Department www FWEparts com Order Hotline 800 222 4393 MANUFACTURING FACILITIES 5599...

Отзывы: