Model identifier: FX-DH116
The functionality of indirect heating: [no]
Direct heat emission: 30(kW)
Indirect heat emission: N/A (kW)
Fuel
Emissions of ambient heat
NOx
Select fuel type
[Liquid]
Kerosene
69 [mg/ kWh
input
]
(GCV)
Element
Symbol Value
Unit
Element
Symbol
Value
Unit
Heat output
Efficiency (NCV)
Nominal heat
output
P
nom
30
kW
Efficiency at the nominal
heat output
η
th,no
m
100
%
Minimum heat
output (indicative)
P
min
N/A
kW
Efficiency at minimum heat
output (indicative)
η
th,min
N/A
%
Auxiliary power consumption
Type of heat output/room temperature control
(selection)
At nominal heat
output
el
max
0,002
kW
Single-stage heat output, no room
temperature control
[no]
At minimum
heating power
el
min
N/A
kW
Two or more manual steps, no room
temperature control
[no]
In standby mode
el
SB
N/A
kW
With mechanical thermostat room
temperature control
[no]
With electronic room temperature control [yes]
with electronic room temperature control
plus daily time switch
[no]
with electronic room temperature control
plus weekly time switch
[no]
Further control options (multiple selections
possible)
Room temperature control, with presence
detection
[no]
Room temperature control, with open
window detection
[no]
With distance control option
[no]
With adaptive start control
[no]
With the working time limit
[no]
With black ball sensor
[no]