GLOSSARY OF TERMS 

 

 

Abort Delay:

 An option that allows a delay in reporting to the central station. 

 

Authority Level:

 The level of access an individual has when using an alarm panel. 

 

Central Station: 

Location where alarm data is sent during an alarm report

 
Chime Feature:

 An option that allows the code pad to sound a ding-dong whenever an 

entry/exit door is opened. 
 

Codes:

  Can be either User Codes (relating to a person) or Function Codes (a toggle switch to 

turn specific functions on/off).  NOTE: A system may have either 99 four (4) digit codes or 66 
six (6) digit codes, but not a mixture of the two. 
 

Duress Code:

 An option that allows a special code to be sent to the central station that 

indicates the alarm system is being operated under duress. 
 

Forced Arming:

  

An option that allows the system to be turned on (ARMED) with one or more zones open. A 
system that is ready to be “force armed” will flash the 

ready light

. (Note: Those zones that are 

not ready will not create an alarm.) 
 

Function Code: 

A Function Code is either a four (4) or six (6) digit code that has been 

programmed by the installer to operate a device. 
 

Group Bypass: 

An option that allows the user to bypass multiple zones with a single 

operation. 

 
Master Code:

 A master arm/disarm code that can program other user codes. 

 

Multi Area System:

 A system divided into multiple areas in which its own user or users control 

each area. 
 

Partial Arm: 

A mode used to arm the perimeter and unused areas of an occupied premises. 

 
Perimeter:  

The outer edge of the protected area. 

 

Quick Arm:

 An option that allows you to turn on (ARM) the security system by pressing either 

the [

ON

] or [

PARTIAL

] key on the code pad control (for ARMING only) as programmed by the 

installing company. 
 

Universal Arming (Uni Arm)

: When enabled, your alarm system can automatically determine 

whether to arm in the Full mode or in the pre-set Partial mode by looking to see if you exit your 
premises or stay inside after arming your system.  

NOTE

: This feature can be used in 

conjunction with “Quick Arm”. 
  

User Code: 

 A four (4) or six (6) digit entry used to arm or disarm the system.

 

 

 

Содержание NX 4

Страница 1: ...Fu t u r e Sa f e S E C U R I T Y NX 4 8 USER GUIDE www futuresafesec uri ty c o m au 02 9343 0033...

Страница 2: ...Zones 8 Group bypass 8 Changing adding user codes 9 Deleting a User Code 10 Walk Test 10 User Code Authorisation 11 Setting the Door Chime 11 Exit Mode 12 Code Pad Emergency Keys 12 Viewing Alarm Memo...

Страница 3: ...e not ready will not create an alarm Function Code A Function Code is either a four 4 or six 6 digit code that has been programmed by the installer to operate a device Group Bypass An option that allo...

Страница 4: ...Page 3...

Страница 5: ...le condition On Light The on light is on when the system is armed The on light is off when it is disarmed Partial Light The partial light is on when the system is armed in the Partial Mode All non byp...

Страница 6: ...of an exit delay and beeps 1 second at the end of the exit delay Pulses when the armed status changes and the AC power is off Pulses when the armed status changes and any zone s is bypassed Pulses wh...

Страница 7: ...bout to expire Key Sequence Operation Example shows a User code of 1234 being used to set the system to the ON Mode FULLY ARMING THE SYSTEM QUICK ARM MODE 1 2 ON is used when the user is away from the...

Страница 8: ...TIAL key The bypass light will illuminate if any zone s is bypassed The light s corresponding to the bypassed zone s will illuminate alerting the user that a zone s may be unprotected and can be fault...

Страница 9: ...disarmed any zones which have been temporarily isolated or bypassed will be reset and will therefore be protected when the system is armed again To manually un bypass zones perform the bypassing proce...

Страница 10: ...ES On occasion you may need to change your arm disarm codes either as a security measure or for your own convenience User Codes are 4 digits long and must all be different to each other A master Code...

Страница 11: ...5 0 3 3 4 WALK TEST Walk test is used to test the functionality of your entire zones and should be performed regularly When in walk test mode the code chime sounder will sound each time a zone is act...

Страница 12: ...3 4 SETTING THE DOOR CHIME Chime Mode provides only an audible warning at the premises A ding dong is sounded from the code pad when the protected area is entered for example when an infant opens the...

Страница 13: ...code pad to provide support in the areas of personal safety medical alert and fire alarm You must hold these keys for two 2 seconds to activate these functions You should press these keys only in an e...

Страница 14: ...s and will light steady those zones that were bypassed during the last alarm RESET LATCHED ALARMS To reset Smoke Detectors Zone Troubles and Zone Tampers the Reset Latched Alarms function must be used...

Страница 15: ...Enter the day of the week 1 Sunday 7 Saturday Eg 3 for Tuesday 4 Enter the month code This must always be two 2 digits Eg 0 7 for July 5 Enter the day code This must always be two 2 digits Eg 0 5 for...

Страница 16: ...hows setting time as 9 30am 1 Press 9 7 2 Enter the master code 3 Enter the hour code which must be two 2 digits Eg 0 9 for 9am 4 Enter the minutes code which must be two 2 digits Eg 3 0 for 30 minute...

Страница 17: ...e formats are selected To program a new phone number you must do the following Key Sequence Operation 1 Press 2 Enter 4 2 for the location of phone number 2 Enter 4 1 for phone number 1 and 4 3 for ph...

Страница 18: ...he master code You are now in the view mode and the first phone digit will be displayed Use the following table to read the code pad lights 4 Press the key to move to the next digit s 5 Press to end a...

Страница 19: ...4 Press the BYPASS key 5 Press to end and exit 4 1 1 2 3 4 SET CODE PAD TONES Each code pad can have its sounder tone frequency adjusted to your individual requirements Follow the steps bellow to adj...

Страница 20: ...irens and communicator should be tested regularly The key sequence below is used to perform the siren and communicator test Key Sequence Operation 1 Enter keys 4 4 to initiate the test option 2 Enter...

Страница 21: ...wing which zone s has a low battery This only applies to wireless zones Press the key to return to the 1 of 8 service lights 4 ZONE LOSS OF SUPERVISION Press the 4 key and the zone light s will illumi...

Страница 22: ...ZONE DESCRIPTIONS 24 HOUR PARTIAL MODE ENTRY EXIT 1 2 3 4 5 6 7 8 INSTALLATION COMPANY DAS 4 8VerteX 1200A...

Отзывы: