Document 8K088X04 R5.01
Portable Digital Repeater Programming Guide
Page 43 of 86
Repeater
Repeater
Operation
Base
Repeater
Specifies whether station is
operating as a Base mode or
Repeater mode.
Base-
local repeat is
unavailable (Full Duplex, Half
Duplex and Simplex are
supported)
Repeater-
local repeat
available on Full Duplex
channels only (depending on
Gate Parameters)
Repeater Gate
Update
Disabled
Enabled
Specifies how the station
determines its state after a reset.
Enabled:
the station comes up in
the state last requested by the
console (Repeater Set Up or
Repeater Knocked Down)
Disabled:
the station comes up in
the state specified by the Repeater
Gate Startup State field.
This field is only accessible
when Repeater Operation is
set to Repeater.
Repeater Gate
Startup State
Repeat Set Up
Repeat Knocked
Down
Specifies the station's state after a
reset: Repeat Set Up or Repeater
Knocked Down
This field is only accessible
when Repeater Operation is
set to Repeater AND Repeater
Gate Update is Disabled.
Start up
Start on Last
Active Channel
Disabled
Enabled
Specifies if the PDR800 starts on
the last active channel after a reset.
Startup Channel
1-64
1
Specifies the channel to which
PDR8000 is set after a reset.
This field is ignored when
Startup on Last Active
Channel field is set to
Enabled.
BSI Interval
1-60 minutes
30 min
Specifies the time interval at which
the FCC assigned station call sign
is broadcast.
Astro Fade
Tolerance
1-3 frames
3
Specifies the number of missed
frames before ASTRO message is
considered terminated.
P25 Frame Sync
Detection Timer
30-255 ms
100 ms
Specifies for how long the
PDR8000 digital decoder waits for
P25 digital signaling (Frame Sync)
before it assumes that the received
signal is analog.