00036119.DOC, Version 1.2
22/28
The fixture’s base enables to be mounted in two ways.
The Moving-Head can be placed directly on the stage floor or rigged in any orientation on a truss without
altering its operation characteristics (see the drawing).
For overhead use (mounting height >100 cm), always install an appropriate safety bond.
You must only use safety bonds complying
with DIN 56927, quick links complying with
DIN 56926, shackles complying with DIN EN
1677-1 and BGV C1 carbines. The safety
bonds, quick links, shackles and the
carbines must be sufficiently dimensioned
and used correctly in accordance with the
latest industrial safety regulations (e. g. BGV
C1, BGI 810-3).
Please note:
for overhead rigging in public
or industrial areas, a series of safety
instructions have to be followed that this
manual can only give in part. The operator
must therefore inform himself on the current
safety instructions and consider them.
The manufacturer cannot be made liable for
damages caused by incorrect installations or
insufficient safety precautions!
Install the safety bond by inserting the quick link in the hole on the bottom of the base Pull the safety bond
over the trussing system etc. Insert the end in the quick link and tighten the fixation screw.
The maximum drop distance must never exceed 20 cm.
A safety bond which already hold the strain of a crash or which is defective must not be used again.
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!
Screw one clamp each via a M12 screw and nut onto the Omega-holders.
Insert the quick-lock fasteners of the first Omega-holder into the respective holes on the bottom of the
device. Tighten the quick-lock fasteners fully clockwise. Install the second Omega-holder.