00123552.DOCX, Version 1.0
39/60
The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety
precautions!
Install the safety bond by inserting the quick link in the hole of the mounting plate on the bottom of the base.
Pull the safety bond over the trussing system etc. Insert the end in the quick link and tighten the fixation
screw.
The maximum drop distance must never exceed 20 cm.
A safety bond which already hold the strain of a crash or which is defective must not be used again.
Screw both clamps via a M10 screw and and self-locking nut onto the Omega-
clamps.
Insert the quick-lock fasteners of the first Omega-clamp into the respective holes
off the mounting plate on the bottom of the device. Tighten the quick-lock
fasteners fully clockwise. Install the second Omega-clamp.
1
2
3
4
(1)
Omega-holder
(2)
Clamp
(3)
Safety-rope
(4)
Quick-lock fastener