Before you Start Check, Check the Following:

- The product is in good condition
- No damage to any parts

In

st

al

la

ti

o

n

S

ta

ge

 1

 

Page 5 of 20 // email [email protected]  tel: +44 (0) 1438 833577  fax: +44 (0) 1438 833565

PIC SD - Picture Side Mechanism

You will receive your mechanisms with the wall plate in the centre of the frame. 
This is in the easiest position to mount straight onto the wall.
Start by marking where the mechanism will go on the wall. Mark centre points through
both the key hole slots, shown in the right detail view. Make sure the mechanism is
level using a spirit level.

Refer to the Tech Sheets
for further dimensions

25mm [1]

Marking Mechanisms Positions

These dimensions can differ depending on the moving panel frame work.

Содержание PIC SD

Страница 1: ...SSUE 002 InstallationInstructions PICSD PictureSideMechanism Design Highlights Range of Sizes of Mechanism Smooth Quiet Motion Optional to Combine with a Motorised Bracket Complete Sheet Metal Cassette Ensures Simple Installation Range of Panel Designs Available Thank you for choosing futureautomation ...

Страница 2: ...n result in serious personal injury or damage to equipment Future Sound Vision trading as Future Automation intend to make this and all documentation as accurate as possible However Future Automation makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this p...

Страница 3: ...Mechanism 6 Stage 3 Mounting The Mechanism 7 Control Box Set Up 7 Stage 4 Testing The Mechanism 8 Stage 5 Fitting The Moving Panel To The Mechanism 9 Stage 6 Adjusting The Stop Positions 10 Stage 7 Mounting The Screen 11 Stage 8 Controlling The Mechanism 12 Final Checks 12 Mechanism Movement 12 Electrical Connections Electrical Connections In The Control Box 13 Contact Closure 14 Warning Lights 15...

Страница 4: ...by misuse or damage accidental or otherwise or service modification by persons not authorised by Future Automation or the use of any non Future Automation supplied parts Any electrical or other environmental work external to your Future Automation mechanism including power cuts surges or lightning strikes Additional items not supplied by Future Automation although they may have been supplied toget...

Страница 5: ...sm 1 1 Frame Horizontal Member 1 2 Frame Vertical Member 1 3 Drive Belt 1 4 Motor 1 5 Wall Plate 1 6 x8 Moving Panel Brackets 2 Control Box 3 IR Remote Control Not Shown On Page 4 x2 AAA Batteries 5 x8 M6 Nuts Bolts 6 Mains Power Other Leads 2 PIC SD Picture Side Mechanism Available in 2 standard sizes PIC SD1 2 Custom sizes also available 1 6 1 1 3 1 1 1 4 1 5 1 1 1 2 1 2 ...

Страница 6: ...hanisms with the wall plate in the centre of the frame This is in the easiest position to mount straight onto the wall Start by marking where the mechanism will go on the wall Mark centre points through both the key hole slots shown in the right detail view Make sure the mechanism is level using a spirit level Refer to the Tech Sheets for further dimensions 25mm 1 Marking Mechanisms Positions Thes...

Страница 7: ...reSideMechanism Mounting the Mechanism Once marked put appropriate fixings into the marked points Offer the mechanism to the wall and secure in place using appropriate fixing Make sure to run the mechanism power cables through the hole in the wall Make sure the mechanism is level using a spirit level Cable entry exit hole ...

Страница 8: ...ame left to right to gain access to the top and bottom mounting slots Make sure the mechanisms are fixed securely and safely THE CONTROL BOX MUST BE IN AN EASILY ACCESSIBLE LOCATION Wire up the control box refer to page 13 Electrical Connection Connect the control box to the mains power supply Connect the infrared remote sensor even if you are going to use switch control Cables can be easily exten...

Страница 9: ...Make sure the frame is square and wont clash into anything in it s moving path Make sure the control box is connected correctly and the cables wont catch on the mechanism Controlling the Mechanism The supplied IR remote performs the following functions OUT Reveal Screen IN Hide Screen STOP Stop Safety Note When the mechanism is moving if any button is pressed apart from IN and OUT it will stop the...

Страница 10: ...anel brackets make sure to allow 10mm clearance from the back of the panel to the wall as shown above 10mm Fitting the Moving Panels to the Mechanisms To make sure the moving panel doesn t fall off the mechanism attach the moving panel brackets as shown To alter the level of the moving panel adjust the height of these bolts which the moving panel brackets sit on ...

Страница 11: ...co uk tel 44 0 1438 833577 fax 44 0 1438 833565 PICSD PictureSideMechanism Adjusting the Stop Positions To alter the stopping positions of the moving panel loosen these 2 bolts on both sides and then slide the bracket left to right to determine the finish positions ...

Страница 12: ...creen In some cases the moving panel will be hiding something else other than a screen such as a safe or hi fi which might already be installed otherwise mount the screen into the recess A range of screen mounts can be found in our catalogue or website Models we recommend are the V2 V3 V63 V74 PF60 The V74 mount is shown within the diagram mounting a 48 screen ...

Страница 13: ... email info futureautomation co uk tel 44 0 1438 833577 fax 44 0 1438 833565 PICSD PictureSideMechanism Final Checks Make sure the mechanism is fixed securely and safely and nothing is in the path of the moving panel Mechanism Movement ...

Страница 14: ...reautomation co uk tel 44 0 1438 833577 fax 44 0 1438 833565 PICSD PictureSideMechanism Connections The mechanism must be connected to all DC controls Connect infrared sensor here Remove this screw to release the lid Ensure the plug is connected correctly and secure ...

Страница 15: ...rs 568A 568B 1 12V SUPPLY 12V SUPPLY CURRENT LIMITED W G W O 2 12V LATCH When 12V attached device will go OUT When 12V removed device will go IN G O 3 GROUND GROUND W O W G 4 PIN 4 NOT USED BL BL 5 DEVICE LATCH Short to GROUND pin 3 device will go OUT remove short device will go IN W BL W BL LED 4 6 DEVICE STOP Momentary short to GROUND pin 3 stops device in current position O G LED 3 7 DEVICE OUT...

Страница 16: ...end stop positions for right panel DC1 Controls DC motor for left panel DC2 Controls DC motor for right panel Operation Details SLQV RS232 Use an RJ25 connector in the socket marked RS232 on the control box to operate using RS232 Details Baud rate 9600 Stop bit 1 Parity None Databits 8 Pin 1 RX Pin 6 TX Pin 3 4 GROUND Pin 2 TX Pin 3 RX Pin 5 GROUND IMPORTANT Ensure protocol is entered exactly as w...

Страница 17: ...ds x2 AAA batteries which are provided within the packaging Out Reveals the screen In Hides the screen Stop Will stop the operation at any point Operation Buttons Replacing Batteries Mechanism Reference Store Store Right Clears Memory Store Store Out References Mechanism Safety Note When the mechanism is moving if you press any button apart from IN and OUT it will stop the operation ...

Страница 18: ...your installer Symptom Cause Remedy Page Remote control or batteries faulty Replace batteries or remote to check batteries view controler through a camera screen and press buttons controller light should be visible 14 Motor end stops incorrectly set Adjust end stop 9 Incorrect pin configuration Terminate 8 pin RJ45 to 568 b pin configuration 12 Faulty wiring Replace connector or cable 13 Faulty co...

Страница 19: ...on co uk tel 44 0 1438 833577 fax 44 0 1438 833565 PICSD PictureSideMechanism Test Motor Operation If the mechanism is not working it is possible to test the motor directly To do so locate and open the control box B A Motor direct drive Motor A B 12V Supply ...

Страница 20: ...tion 110W 110W Power Consumption On Standby 3W 3W Lifting Capacity Kg 10Kg 22 0lb 10Kg 22 0lb Standard Colour BLACK BLACK Picture Movement 1184mm 46 6 1435mm 56 5 Control IR Remote RS232 Contact Closure IR Remote RS232 Contact Closure Power Supply 240V or 110V 240V or 110V Control Of 3rd Party Product Yes Yes Output Power Supply 12V 240V 12V 240V Control Box Size W D H 150x150x52mm 5 9x5 9x2 150x1...