In
st
al
la
ti
o
n
:
E
le
ct
ric
al
C
on
ne
ct
io
n
Page 11 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
PD3.5 - Projector Drop Mechanism
Connections
- The mechanism must be connected to both the AC1 and DC1
-
Optional -
Electric screen can be connected using the control box using the AC2 block
- The AC2 output can only control a 240V / 110V motorised screen to work simultaneously
with the projector
Connect IEC
power lead here
Connect infrared
sensor here
Remove this screw
to release the lid
240v
AC1 Connection
110v
Yel/Grn
Earth
Green
Black
Live B
Red
Brown
Live A
Black
Blue
Neutral
White