7
Battery Installation / Charging
Built-in overcharging protection prevents damage if the unit is left on charge
after being fully charged. There is also protection to prevent charging alkaline
batteries.
CAUTION:
Do not attempt to charge alkaline or other
disposable batteries.
NOTE:
Do not charge Ni-MH batteries when ambient temperature
exceeds 113° F (45° C) or is less than 32° F (0° C).
The rechargeable battery electronics include a charge status and charge error
indicator located on the back of the housing.
Charge Status Indicator:
The LED will remain solid when the unit is charging.
The LED will blink when fully charged. When charged, unplug the charger from
the outlet and remove the cannon adapter from the accessory connector.
Charge Error Indicator:
If the batteries seem to be in a totally drained state
initially, the charge circuit will try to gradually charge the batteries. If charging
is unsuccessful after approximately 20 minutes, the LED will turn on solid
indicating an error with the internal battery connection, improper battery
insertion, the wrong type of battery, or a dead battery cell.
A blinking charge error LED indicates the unit is too hot or too cold to charge.
Charging will automatically start when the temperature is within the above
noted ranges.
Battery Replacement
- Remove dust cap, loosen thumbscrews, and remove
battery access cover. Remove old batteries. Install new batteries as described
on previous page.
Refer to your local requirements for the proper disposal of batteries.
(Located on lower rear of polycarbonate housing)
Charge Status Indicator
Solid - Charging
Blinking - Charging Complete
Charge Error Indicator
Solid - Battery Problems
Blinking - Temperature
out of limits