should guarantee the bottom minimum height of 1.8 m from the
ground, ceiling, roof, or other coverings minimum distance is 0.2 m,
the minimum distance with both sides wall is 0.5 m (as shown in fig.
1).
c. Install set screw
According to the product installation location, three position with
percussion drill diameter of 8 mm round hole (as shown in fig. 2), and
then insert the expansion screws, respectively. Install the bracket in
the wall and make sure the installation point security firm (as shown
in fig. 3).
Installation the Infrared Heater
1.
Attention before installation
a)
The product is fragile and should be taken gently.
b)
The installation is not recommended under some acid or alkali
environment.
c)
Product must be reliable ground connection.
d)
Check the product rating label marking if it is consistent with local
voltage.
e)
Ensure the power level have adequate current-carrying capacity.
2.
Installation locations
In order to use the appliance safely, the distance of appliance from
the ground should be a minimum 1.8m, the distance of appliance
from the ceiling
、
roof or other coverings should be a minimum 0.2m,
and the distance of appliance from the both sides of walls should be
a minimum 0.5m (Fig. 1)
3.
Install the fixed screw on wall
According to the appliance installation location, using percussion
drilling to make three circle holes which diameter is 10-11 mm (Fig.
2), and insert the expansion screws respectively. Install the
bracket on the wall and make sure it is safety and strong enough
(Fig. 3).
4.
Fix the product
Removing all the packages on the appliance (especially shake
proof foam in the heating tube), fix the activity plate and bracket
by butterfly screws and adjust the angle of the appliance.
Turn power on, observe 5 to 8 minutes, to make sure the functions
are normal.