background image

 

10

Futrex Connect Advanced Software 
 
 

The Futrex Connect software provided with your FUTREX-6100 software allows you to 

connect the FUTREX-6100 to a Windows PC via the USB port on the instrument to store clients, 
view graphs with changes over time, see full two page color reports, and other features.  
 
 

In addition to this manual, you will find three supplement “Instructions for Use” 

documents included with your instrument: 
 
1. 

Futrex Connect Software Set-Up Guide 

2. 

FUTREX-6100 Futrex Connect Software Manual 

3. 

FUTREX-6100 Instructions for Host Mode 

 
 

A digital copy of these Instructions for Use (as well as this document) are available on 

the USB drive that was included with the instrument. Should you have questions during the set-
up of the Futrex Connect software do not hesitate to contact Futrex Tech, Inc. 

 

Admin Functions on the Stand-Alone FUTREX-6100  
 
 

There are a few back-end functions on the FUTREX-6100 that can be adjusted, 

depending on the region the device is being used in, or the mode it is to be used in. These will be 
used infrequently.  
 
Function Mode Options 
F1 - Selection of English or Metric units. 
F2 - Not used. 
F3 - Not used. 
F4 - Not used. 
F5 - Selection of Warning Signal that two minutes have passed without any key pressed. 
F6 - Not used. 
F7 – Selection of Host Mode or Stand Alone Mode (See IFU “Instructions for Host Mode). 
F8 - Not Used. 
 
Entering into the Function Mode 
 

1.

 

Turn Power Switch ON. 

2.

 

Press the SELECT PROGRAM Key. 

3.

 

Press the F-MODE Key. 

4.

 

The Letter "F_" will appear on the screen. 

 
F1 – Selection of English or Metric Units 
 

The subject's height and weight values can be printed in English (lbs/in), or (Kg/cm) 

units.  After entering the Function Modem and "F" is displayed, type "1". The display will either 
show "English" or "Metric".If you desire to change, press the SELECT PROGRAM pushbutton.  
Then press "CLEAR". 
 

Содержание FUTREX-6100

Страница 1: ...1 FUTREX 6100 Owner s Manual Revision 6 0 Revision Date January 20 2020 Futrex Spotcheck Inc 130 WESTERN MARYLAND PARKWAY HAGERSTOWN MD 21740 1 301 733 9368 FAX 1 301 733 4660 E mail info futrex com...

Страница 2: ...6100 Page 5 Service Requirements Page 5 Appearance and Part Names Page 6 Setting Up the FUTREX 6100 Page 7 Body Fat Measuring Procedure in Stand Alone Mode Pages 8 9 Locating the Biceps Measuring Site...

Страница 3: ...d healthcare provider The FUTREX 6100 is not intended to be a diagnostic device and is for screening purposes only Read all of the information in the Owner s Manual before operating the device Operate...

Страница 4: ...arranty Information The following warranty card is included with your FUTREX 6100 Please read the card and return it to Futrex Support is available by calling 301 733 9368 or E Mailing service Futrex...

Страница 5: ...nty period or following please contact Futrex Support and Service at 301 733 9368 or via e mail Service Futrex com Futrex is the only authorized service representative for Futrex products DO NOT attem...

Страница 6: ...rt Names The FUTREX 6100 consists of the following items 4 AC Adapter 5 Optical Standard 6 Light Shield 7 USB Cable 8 Biceps Locator 9 Fitness Wheel 2 Light Wand 3 FUTREX 6100 Software 1 Main Device C...

Страница 7: ...y Be sure the batteries are oriented as indicated in the battery compartment 2 Connecting the Light Wand Ensure the Light Wand Connector is attached to the Main Body Connector NOTE Futrex recommends a...

Страница 8: ...lver stripe on the Light Wand with the silver stripe on the Optical Standard Figure 3 3 To start the measurement sequence press ENTER The instrument will then request an ID number this is only needed...

Страница 9: ...Reading 9 Percent body fat will then be printed and displayed 10 Press CLEAR to perform another measurement 11 When finished turn power switch to OFF CAUTION Do not move the Light Wand while the word...

Страница 10: ...Inc Admin Functions on the Stand Alone FUTREX 6100 There are a few back end functions on the FUTREX 6100 that can be adjusted depending on the region the device is being used in or the mode it is to...

Страница 11: ...date format stored within the FUTREX 6100 XL a Press the SELECT PROGRAMS Key b Press the DATE Key and step to the DATE selection Press ENTER and the current date will be displayed c To change displaye...

Страница 12: ...o toggle between the valid decimal delimiters and thousands separators 9 999 99 and 9 999 99 respectively Figure 5 and Figure 6 Futrex Connect Sample Results Printouts IMPORTANT Please set up your Fut...

Страница 13: ...H non condensing Operating Temperature Humidity Barometric Pressure Range Temperature 50 F to 104 F 10 C to 40 C Humidity 15 90 RH non condensing Barometric Pressure 105kPa to 80 kPa 790 600 mmHg Tabl...

Страница 14: ...le Accurate Measurements document b Use an alcohol swab to gently clean the light wand c Take the measurement on the other bicep if possible d Ensure that the probe is fully seated in the optical stan...

Страница 15: ...the product does cause harmful interference to radio or television reception which can be determined by turning the product on and off the user is encouraged to try to correct the interference by one...

Страница 16: ...16 Futrex Spotcheck Inc 130 WESTERN MARYLAND PARKWAY HAGERSTOWN MD 21740 1 301 733 9368 FAX 1 301 733 4660 E mail info futrex com...

Отзывы: