11
TEDS MENU
1. Menu
2. TEDS Data
3. TEDS Device — Will show information about TEDS chip.
4. TEDS Pages — Shows programmed information stored
in chip.
5. Load Data — Will load TEDS information into IPM650.
6. Auto Detection — Sets the IPM650 to automatically
load TEDS information upon power on.
CHANNEL SELECT (CALIBRATION PROFILE SELECT)
1. Menu
2. System Setting
3. Channel Select
4. Use the left and right arrow key to choose the desired
channel.
5. Enter to load Channel or Profile.
TEDS and Channel Select
TEDS is a small chip that can store a sensor’s calibration infor-
mation. The IPM650 can read it upon power up, or by loading
it through the menu, and setup a profile with the stored
information.
TEDS calibration information can be viewed upon loading
TEDS, either during a power on or while selecting Load Data
under the TEDS menu.
The TEDS chip should be placed within 5ft. of the IPM650
sensor connection to maintain proper power. Typically the
TEDS chip is placed in the sensor binder connector.
An auto-calibration may be performed when loading TEDS
information, or a new channel or profile.
TIPS FOR USING TEDS AND CHANNEL SELECT