TECHNICAL SPECIFICATIONS 

DISTY40 

DISTY80

measuring range

0,05 to 40m

0,05 to 80m

measuring accuracy

± 2mm

measuring units

m / inch / ft

laser classification

class ii

laser type

635nm, <1 mw

distance measurement with tilt sensor

P

horizontal measurement range

±90°

horizontal measurement accuracy

±0,5°

area, volume measurement

P

indirect measurement

P

pythagoras proposition

P

plus-munus method

P

continuous measurement

P

minimum/maximum measurement

P

display illumination

P

show beep

P

multifunctional end piece

P

protection against splashes and dust

ip54

historical storage

99

temperature range of operation

-10°c to 50°c

temperature range of storage

-20°c to 60°c

battery life

up to 4000 measurements

batterie selection

tyoe aaa - 2x 1,5v

laser switch-off automatically

after 30 seconds

instrument switch-off automatically

after 3 minutes

dimensions

115 x 48 x 29mm

weight

0,11kg (without battery)

FUTECH instruments are made with carefully select-

ed components and crafted with the utmost care. 

By that, we can offer you an optimal quality. If your 

device should however be defective due to faulty 

materials or a production error, you can benefit from 

a 2 years manufacturer’s warranty. 

During this period, your instrument will be repaired 

or replaced for free if following conditions are met:

1. 

Your device has been purchased less than two 

years ago from an authorized FUTECH distrib-

utor. Please provide a copy of the invoice that 

indicates the type and the serial number of 

your faulty device.

2. 

You deliver the faulty device to an authorized 

FUTECH distributor in its original protective 

packaging (pouch in fabric, plastic suitcase ...).

3. 

The device shows no damage caused by in-

correct usage (eg. Crack(s) from a fall, inter-

nal water damage, fuses melted by the use of 

an inappropriate charger or adapter, battery 

leakage, device opened by a non-authorised 

technician, ...)

The manufacturer’s warranty does not include peri-

odic maintenance works (eg. Annual adjustments) 

nor the included batteries.

FUTECH is a registered trademark of LASETO N.V. 

in Belgium (BE 0808 043 652) available at iwww.

futech-tools.com.

Содержание DISTY40

Страница 1: ...DISTY40 DISTY80 201 40 201 80 MANUAL...

Страница 2: ...evice dur ing transportation Regularly inspect the accuracy of the instrument especially when starting any major square setting work You have sole responsibility for the accuracy of your work Do not u...

Страница 3: ...Off button 12 Laser active 13 Referencepoint in front 14 Referencepoint at the back 15 Reference point positioning bracket 16 Max and Min measurement 17 Surface Volume 18 Indirect measurement Single p...

Страница 4: ...n be adapted for the following measuring situations For measurements from an edge fold out the positioning bracket until it first locks in place corner of 90 For measurements from a corner open the po...

Страница 5: ...each single measurements can be deleted and remeasured in series Reference The default reference setting is from the rear of the instument The display will show you Press the button to change the refe...

Страница 6: ...ton and hold down this button until you hear a beep Then slowly sweep the laser back and forth and up and down over the desired target point e g into the corner of a room Press the button to stop cont...

Страница 7: ...rs in the display Press the button to take the first measurement e g length Press the button to take the second measurement e g widht Press the button to take the third measurement e g height The resu...

Страница 8: ...t All target points must be in a horizontal or vertical plane The best results are achieved when the instrument is rotated about a fixed point e g with the position bracket fully folded out and the in...

Страница 9: ...al sode on the second link The calculated height on the third line Keep in mind that the lenght ofthe horizontal line is only 100 correct when a precise vertical measurement is performed Double indire...

Страница 10: ...d third 90 measurement The results are now shown on the screen from top to bottom distance to first upper point distance to the second point distance from the measured horizontal point distance betwee...

Страница 11: ...ge The Disty40 is limited to 40m the Disty80 to 80m At night or dusk and if the target is in shadow the measuring range without target plate is increased Use a target plate to increase the measurement...

Страница 12: ...to counteract them The product is not to be operated until the user has been instructed on how to work with it LIMITS OF USE Environment Suitable for use in an atmosphere appro priate for permanent h...

Страница 13: ...cted to mechanical shock for example blows or falling the product may be damaged or peo ple may sustain injury When setting up the product make sure that the accessories are correctly adapted fitted s...

Страница 14: ...hazards The per son responsible for the product must ensure that all users understand these directions and adhere to them Products classified as laser class 1 class 2 and class 3R do not require lase...

Страница 15: ...lly select ed components and crafted with the utmost care By that we can offer you an optimal quality If your device should however be defective due to faulty materials or a production error you can b...

Страница 16: ...futechtools futech tools Facebook LinkedIn JOIN US futech tools com World Wide Web...

Отзывы: