89
Go to 3/3 from any
cursor position
(6) Revo. Up Dly: Revolution change up delay
How quickly the RPM changes when increasing RPM
between two different RPM conditions and flight modes.
A higher number slows the RPM change rate; a lower
value speeds up the RPM change rate.
Setting ranges: 2 ~ 40 Frm Initial value: 8 Frm
(7) Revo. Dn Dly: Revolution change down delay
How quickly the RPM changes when reducing RPM between two differ-
ent RPM conditions and flight modes. A higher number slows the RPM
change rate; a lower value speeds up the RPM change rate.
Setting ranges: 2 ~ 40 Frm Initial value: 10 Frm
(8) Start Dly: Start delay
How quickly the RPM stabilizes to the set RPM from when the GOV is
turned ON. A higher value slows down the spool up rate; a lower value
speeds up the spool up rate.
Setting ranges: 2 ~ 20 Frm Initial value: 5 Frm
(9) Gov. On. Revo: Governor ON revolution setting
This parameter tells the governor at what percentage of the set rpm it is to
become active. The default value is 60 %. In this case, the governor will
not engage until the engine rpm reaches 60 % of the set rpm. If you feel
that the time for governor engagement is too slow, decrease the value to
50 ~ 55%. The starting time will be faster.
Setting ranges: 50 ~ 90% Initial value: 60%
GOV. EXPERT screen 2/3
From 1/3