11
CYCLE OPERATING
AUTOMATIC OPERATING
While Auto mode is being activated, “auto” “current” is alternately displayed.
AUTO cycle operation is fixed as discharge charge once.
Delay time is fixed as 10 minutes in Auto mode.
NC 000:01 00000
24° 0.00A 00.00V
CHARGE MODE
NiCd AUTOMATIC
ENTER
CHG 000:01 00000
24° auto 00.00V
[NiCd] BATTERY
CHARGE START...
NC 000:01 00000
24° 0.00A 00.00V
DISCHARGE MODE
NiCd AUTOMATIC
ENTER
DCH 000:01 00000
24° auto 00.00V
[NiCd] BATTERY
DISCHARGE START...
D1C 000:01 00000
24° 0.00A 00.00V
CYCLE MODE
NiCd AUTOMATIC
ENTER
D1C 000:01 00000
24° auto 00.00V
[NiCd] BATTERY
CYCLE START...
UP/DOWN
C1D 000:00 00000
00° 0.00A 00.00V
CYCLE MODE
CHG DCH TIME:
ENTER
C1D 000:00 00000
00°
0.00A
00.00V
[NiCd] BATTERY
CYCLE START...
C1D 000:01 00001
26° 6.00A 12.37V
The Charge current can be
changed with UP/DOWN
buttons during charging
CYCLE DISCHARGE
C1D 019:59 01520
26° DELAY 12.37V
C1D 048:23 01520
26° 3.00A 12.37V
CYCLE DELAY
CYCLE CHARGE
CYCLE OPERATING MODE
CHARGE
“C” FLASH
DELAY
“1” FLASH
DISCHARGE “D” FLASH
CYCLE OPERATING MODE
C1D CHARGE, CYCLE TIME, DISCHARGE
D1C DISCHARGE, CYCLE TIME, CHARGE
END OPERATION
If the button is pressed for 2 seconds in the END display, it reverts to the main display.
(If the button is briefly pressed or the battery pack is disconnected, it won’t revert to the
main display.)
Operating data can be referred to the above “7. Data View Display “
During trickle charging, the parameters of “ CHG, TRK, FINISH, trickle current “ are blinking.
Trickle charge
If trickle currents are set to 100~500mAh at “USER CONDITION SETUP”, the trickle charge
•
proceeds with the selected trickle currents.
The trickle charge proceeds with 1/20 currents of the selected capacity in Auto mode,
•
however, there is NO trickle charge in cases of lower than 100mAh.
Even if the trickle currents are set, if a charge process is stopped due to the optional
•
temperature, or safety-timer function, the trickle charge won’t work at all.
ENTER
TRK 120:35 03215
38° FINISH 9.12V
CHG 120:35 03215
38° 5.00A 9.12V
CHARGE MODE
C: 5.0Ad: 15mV/C
CHG 120:35 03215
38° 0.10A 9.12V
ENTER
DCH 38.24 02400
36° FINISH 4.80V
DCH 38:24 02400
36° 2.00A 4.80V
DISCHARGE MODE
C: 2.0A: 0.8V/CELL
ENTER
C1D 142:34 02860
37° FINISH 4.82V
C1D 042:34 02860
37° 2.00A 4.82V
CYCLE MODE
CHC DCH TIME:1
2 SEC
2 SEC
2 SEC
ENTER
ENTER