background image

FusionServer 2298 V5 Server 
Technical White Paper 

1 Product Introduction 

 

2022-06-25 

 

Product Introduction 

FusionServer 2298 V5 (2298 V5) is a new-generation 2U 2-socket rack server designed for 
Internet, enterprise, and telecom applications. 

The 2298 V5 applies to distributed storage, big data analysis, software-defined storage, video, 
backup and archiving, and other storage-intensive cold storage scenarios. It delivers 
unmatched flexibility and expandability of local storage, reduced storage costs, as well as 
high computing performance. 

The 2298 V5 features ultra-high density, superb performance, easy O&M, and high 
expandability. 

 

For details about the 2298 V5 nameplate information, see A.4 Nameplate . 

Figure 1-1

 

2298 V5 

 

 

Содержание FusionServer 2298 V5

Страница 1: ...FusionServer 2298 V5 Server Technical White Paper Issue 03 Date 2022 06 25 xFusion Digital Technologies Co Ltd ...

Страница 2: ...t bear any liability resulting from the use of xFusion The purchased products services and features are stipulated by the contract made between xFusion and the customer All or part of the products services and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this ...

Страница 3: ... 19 5 2 1 Appearance 19 5 2 2 Indicators 20 5 2 3 Ports 22 5 3 Processor 23 5 4 Memory 24 5 4 1 DDR4 Memory 24 5 4 1 1 Memory Identifier 24 5 4 1 2 Memory Subsystem Architecture 25 5 4 1 3 Memory Compatibility 26 5 4 1 4 DIMM Installation Rules 27 5 4 1 5 Memory Installation Positions 28 5 4 1 6 Memory Protection Technologies 30 5 5 Storage 31 5 5 1 Drive Configuration 31 5 5 2 Drive Numbering 32 ...

Страница 4: ... 1 Mainboard 47 5 10 2 Drive Backplane 49 5 10 3 PSU Backplane 51 6 Product Specifications 52 6 1 Technical Specifications 52 6 2 Environmental Specifications 55 6 3 Physical Specifications 57 7 Software and Hardware Compatibility 59 8 Safety Instructions 60 8 1 Security 60 8 2 Maintenance and Warranty 63 9 System Management 64 10 Certifications 66 A Appendix 68 B Glossary 81 C Acronyms and Abbrev...

Страница 5: ...risk which if not avoided will result in death or serious injury Indicates a hazard with a medium level of risk which if not avoided could result in death or serious injury Indicates a hazard with a low level of risk which if not avoided could result in minor or moderate injury Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss performance d...

Страница 6: ... how to measure dimensions Added 5 10 3 PSU Backplane Updated the physical structure diagram and added the PSU backplane information Added A 1 Chassis Label Updated 6 1 Technical Specifications and claimed support for U 2 drives Upgrades the standards of CE UKCA and CCC certifications in the chapter 10 Certifications 02 2022 03 18 Added 10 Certifications 01 2021 12 20 This issue is the first offic...

Страница 7: ...lies to distributed storage big data analysis software defined storage video backup and archiving and other storage intensive cold storage scenarios It delivers unmatched flexibility and expandability of local storage reduced storage costs as well as high computing performance The 2298 V5 features ultra high density superb performance easy O M and high expandability For details about the 2298 V5 n...

Страница 8: ...ddress virtualization workloads Intel Advanced Vector Extensions 512 Intel AVX 512 significantly accelerates floating point performance for computing intensive applications The Cascade Lake processors support Intel Deep Learning Boost vector neural network instructions VNNI to improve the performance of deep learning applications The server supports double data rate 4 DDR4 registered dual in line ...

Страница 9: ...fied Extensible Firmware Interface UEFI improves setup configuration and update efficiency and simplifies fault handling The Advanced Encryption Standard New Instruction AES NI algorithm allows faster and stronger encryption Intel Execute Disable Bit EDB function prevents certain types of malicious buffer overflow attacks when working with a supported OS Intel Trusted Execution Technology enhances...

Страница 10: ...nsures optimal heat dissipation and reduces system power consumption The server is protected with power capping and power control measures Staggered spin up for drives reduces the server boot power consumption Intel Intelligent Power Capability allows a processor to be powered on or off based on requirements Low voltage Intel Xeon Scalable processors consume less energy ideally suited for data cen...

Страница 11: ... 3 1 2298 V5 physical structure 1 Rear drive 2 Rear drive module 3 PCIe riser module 4 Standard PCIe card 5 PSU 6 PSU backplane 7 Chassis 8 Air duct 1 9 Upper layer drive drawer 10 Lower layer drive drawer 11 Fan module bracket 12 Fan module 13 Air duct 2 14 Heat sink 15 Processor 16 DIMM 17 TPM TCM 18 Mainboard ...

Страница 12: ...FusionServer 2298 V5 Server Technical White Paper 3 Physical Structure 2022 06 25 12 19 OCP 2 0 Mezz card ...

Страница 13: ...CIe slots CPU 1 is connected to two full height half length FHHL PCIe 3 0 x8 cards and one PCIe 3 0 x8 OCP 2 0 mezzanine card CPU 2 is connected to two half height half length HHHL PCIe 3 0 x16 cards The server supports 24 front 3 5 inch SAS SATA drives directly connected to a 24 port PCIe SAS HBA card The server supports four rear 2 5 inch SAS SATA NVMe drives that can be directly connected to th...

Страница 14: ...2 06 25 14 The LBG 2 Platform Controller Hub PCH supports Two 10GE optical LOM ports Two GE electrical LOM ports Two SATA or PCIe ports for M 2 SSDs Uses the iBMC management chip and supports a VGA a management network port a debugging serial port and other management ports ...

Страница 15: ...22 06 25 15 5 Hardware Description 5 1 Front Panel 5 2 Rear Panel 5 3 Processor 5 4 Memory 5 5 Storage 5 6 Network 5 7 I O Expansion 5 8 PSUs 5 9 Fans 5 10 Boards 5 1 Front Panel 5 1 1 Appearance Figure 5 1 Front view 1 Drive drawer ejector lever 2 Drive drawer ejector release ...

Страница 16: ...tions Figure 5 2 Indicators and buttons on the front panel 1 Power button indicator 2 Health status indicator 3 10GE optical port LOM port 1 connection status indicator 4 GE electrical port LOM port 3 connection status indicator 5 UID button indicator 6 Non Maskable Interrupt NMI button 7 10GE optical port LOM port 2 connection status indicator 8 GE electrical port LOM port 4 connection status ind...

Страница 17: ...g down this button for 6 seconds will forcibly power off the device When the power indicator is steady yellow you can press this button to power on the device UID button indicator The UID button indicator helps identify and locate a device UID indicator Off The device is not being located Blinking or steady blue The device is being located UID button description You can control the UID indicator s...

Страница 18: ...tatus indicator Each indicator shows the connection status of an Ethernet LOM port Off The network port is not in use or has failed Steady green The network port is properly connected NOTE The indicators correspond to two 10GE and two GE network ports on the mainboard The LOM has a standby power supply and will not be powered off even if the service system is powered off As long as the LOM ports a...

Страница 19: ...B device NOTICE Before connecting an external USB device check that the USB device functions properly The server may operate abnormally if an abnormal USB device is connected VGA port DB15 1 Used to connect a display terminal such as a monitor or KVM 5 2 Rear Panel 5 2 1 Appearance Figure 5 4 Rear view 1 SAS SATA NVMe drives 2 Rear drive module 3 PCIe Slot1 4 PCIe Slot2 5 PCIe riser module 6 PCIe ...

Страница 20: ... rear panel 1 PSU indicator 2 UID Indicator 3 Serial port indicators NOTE The indicators are reserved 4 Connection status indicator of the management network port 5 Data transmission status indicator of the management network port 6 LOM indicators 7 OCP 2 0 mezzanine card indicator Indicator Description Table 5 3 Description of indicators on the rear panel Indicator Description LOM indicators For ...

Страница 21: ...ws Power supply overtemperature protection Power output overcurrent or short circuit Output overvoltage Short circuit protection Device failure excluding failure of all devices UID Indicator The UID indicator helps identify and locate a device Off The device is not being located Blinking or steady blue The device is being located NOTE You can control the UID indicator state by pressing the UID but...

Страница 22: ...0 OCP 2 0 mezzanine card port Port Description Table 5 4 Description of ports on the rear panel Tool Type Quantity Description LOM port 1 10GE optical port 2 For details see 5 6 1 LOMs LOM port 2 GE electrical port 2 For details see 5 6 1 LOMs OCP 2 0 mezzanine card port For details see 5 6 2 OCP 2 0 Mezzanine Cards PSU socket 2 Used to connect to the power distribution unit PDU in the cabinet You...

Страница 23: ...that supports 100 Mbit s and 1000 Mbit s auto negotiation VGA port DB15 1 Used to connect a display terminal such as a monitor or KVM USB 3 0 port USB 3 0 2 Used to connect to a USB device NOTICE Before connecting an external USB device check that the USB device functions properly The server may operate abnormally if an abnormal USB device is connected 5 3 Processor The server supports one or two ...

Страница 24: ...scription 2022 06 25 24 Figure 5 7 Processor positions 5 4 Memory 5 4 1 DDR4 Memory 5 4 1 1 Memory Identifier You can determine the memory module properties based on the label attached to the memory module Figure 5 8 Memory identifier Callout Description Definition ...

Страница 25: ...on the DRAM X4 4 bit X8 8 bit 4 Type of the memory interface PC3 DDR3 PC4 DDR4 5 Maximum memory speed 2133 MT S 2400 MT S 2666 MT S 2933 MT S 6 Column Access Strobe CAS latency P 15 T 17 7 DIMM type R RDIMM L LRDIMM 5 4 1 2 Memory Subsystem Architecture The 2298 V5 provides 12 memory slots Each processor integrates six memory channels Table 5 5 Memory channels CPU Memory Channel Memory Slot CPU 1 ...

Страница 26: ...h rank and height cannot be used together Contact your local sales representative or use the Compatibility Checker to determine the components to be used The memory can be used with Intel Xeon Scalable Skylake and Cascade Lake processors The maximum memory capacity supported varies depending on the processor model Skylake processors M processors 1 5 TB socket Other processors 768 GB socket Cascade...

Страница 27: ...eed MT s 1DPCc 2666 2933d 2666 2933d 2933d a The maximum number of DDR4 memory modules is based on dual processor configuration The value is halved for a server with only one processor b The maximum DDR4 memory capacity varies depending on the processor type The value listed in this table is based on the assumption that DIMMs are fully configured c DPC DIMM per channel indicates the number of DIMM...

Страница 28: ... two integrated memory controllers IMCs At least two channels of each IMC are used for installing memory modules channels 1 and 2 or channels 1 2 and 3 The installed memory modules must be identical in size and organization For a multi processor configuration each processor must have a valid memory mirroring configuration Memory scrubbing mode Comply with the general installation guidelines 5 4 1 ...

Страница 29: ...FusionServer 2298 V5 Server Technical White Paper 5 Hardware Description 2022 06 25 29 Figure 5 9 Memory slots Figure 5 10 DDR4 memory installation guidelines 1 processor ...

Страница 30: ...ction Technologies The following memory protection technologies are supported ECC Full mirroring Address range mirroring SDDC SDDC 1 Rank sparing mode Static virtual lockstep Faulty DIMM isolation Memory thermal throttling Memory address parity protection Memory demand patrol scrubbing Device tagging Data scrambling Adaptive double device data correction ADDDC ADDDC 1 ...

Страница 31: ... NVMe drives Built in drive 2 Two built in M 2 SSDsa Front drawer drive SAS HBA cardb Rear drive PCIe RAID controller cardc PCH pass through d CPU pass through e The PCIe RAID controller card must be installed in slot 2 Built in drive PCH pass through Configuration 2 Front drawer drive 24 x 3 5 24 Slots 0 to 23 support only SAS SAT A drives Rear drive 4 x 2 5 4 Slots R0 to R3 support SAS SAT A NVM...

Страница 32: ...s SATA and PCIe interfaces b Front hard drives are configured with 24 port SAS HBAs c Supports PCIe RAID controller cards when the rear drives are configured with SATA or SAS drives d Supports PCH pass through when the rear drive is configured with SATA drives e Supports CPU pass through when the rear drive is configured with NVMe drives f The PCIe RAID controller card in slot 2 manages both front...

Страница 33: ...FusionServer 2298 V5 Server Technical White Paper 5 Hardware Description 2022 06 25 33 Figure 5 12 Drive numbering Rear drives Figure 5 13 Drive numbering Built in drives M 2 SSD 0 1 ...

Страница 34: ...FusionServer 2298 V5 Server Technical White Paper 5 Hardware Description 2022 06 25 34 Figure 5 14 Drive numbering ...

Страница 35: ...ation indicators of the front drive drawer Drive Identification Indicator Blue Description Steady on The drive is being located Off The drive is not in position Table 5 9 Description of status indicators of the front drive drawer Activity Indicator Green Fault Indicator Yellow Description Blinking at 0 5 Hz Off The RAID group is being rebuilt or the member drive is being replaced Blinking at 1 Hz ...

Страница 36: ...d off for 3s The RAID group rebuilding is suspended Off Off The drive is not in position SAS SATA Drive Indicators Figure 5 16 SAS SATA drive indicators Table 5 10 Description of SAS SATA drive indicators Activity Indicator Green Fault Indicator Yellow Description Off Off The drive is not in position Steady on Off The drive is detected Blinking at 4 Hz Off Data is being read or written normally or...

Страница 37: ...2 Hz Off Data is being read from or written to the NVMe SSD Off Blinking at 2 Hz The NVMe drive is being located Steady on Off Steady on The NVMe drive is faulty If the VMD function is disabled NVMe drives support only orderly hot swap Table 5 12 NVMe drive indicators VMD disabled Activity Indicator Green Fault Indicator Yellow Description Off Off The NVMe drive cannot be detected Steady on Off Th...

Страница 38: ...y yellow The M 2 FRU is faulty or not detected M 2 FRU activity indicator Off The M 2 FRU is not in position or is faulty Blinking green Data is being read written or synchronized Steady green The M 2 FRU is inactive 5 5 4 RAID Controller Card The RAID controller card supports RAID configuration RAID level migration and drive roaming If SAS SATA drives are used as rear drives a RAID controller car...

Страница 39: ...0M Use Compatibility Checker to obtain information about the cables and optical modules supported by the LOM ports The LOM ports support NC SI WOL and PXE The LOM ports do not support forced rates The electrical LOM ports cannot be connected to power over Ethernet PoE devices such as a switch with PoE enabled Connecting a LOM port to a PoE device may cause link communication failure or even damage...

Страница 40: ...l port 4 Connection status indicator of a GE electrical port Indicator Description Table 5 15 LOM indicators Indicator Description Connection status indicator Data transmission status indicator for a 10GE optical port Off The network port is not connected Blinking green Data is being transmitted Steady green The network port is properly connected Data transmission rate indicator for a 10GE optical...

Страница 41: ...ion Contact your local sales representative or use the Compatibility Checker to determine the components to be used Table 5 16 OCP 2 0 mezzanine card supported by the 2298 V5 NIC Type Chip Model Port Type Number of Ports NC SI WOL PXE OCP 2 0 mezzanine card CX5 25GE optical port 2 Indicator Positions OCP 2 0 mezzanine card indicators 2 x 25GE optical ports Figure 5 21 OCP 2 0 mezzanine card indica...

Страница 42: ... yellow The data transmission rate is 10 Gbit s 5 7 I O Expansion 5 7 1 PCIe Cards PCIe cards provide ease of expandability and connection Four slots for standard PCIe cards are supported The electrical ports provided by PCIe NICs cannot be connected to power over Ethernet PoE devices such as a switch with PoE enabled Connecting such an electrical port to a PoE device may cause link communication ...

Страница 43: ...5 7 3 PCIe Slot Description The PCIe slots mapping to a vacant CPU socket are unavailable Table 5 18 PCIe slot description PCIe Slot CPU PCIe Stand ards Conne ctor Width Bus Width Port No Root Port B D F Device B D F Slot Size LOM CPU1 PCIe 3 0 x8 x8 Port1C 85 02 0 89 00 0 OCP 2 0 mezzan ine CPU 1 PCIe 3 0 x8 x8 Port1A 17 00 0 18 00 0 ...

Страница 44: ...tended PCIe device The PCIe x16 slots are backward compatible with PCIe x8 PCIe x4 and PCIe x1 cards The PCIe cards are not forward compatible That is the PCIe slot width cannot be smaller than the PCIe card link width The full height half length FHHL PCIe slots are backward compatible with half height half length HHHL PCIe cards All slots support PCIe cards of up to 75 W The power of a PCIe card ...

Страница 45: ... 127 V AC the output power decreases to 1000 W Two 1500 W AC Platinum PSUs can serve as 1700 W PSUs Figure 5 24 PSU positions 5 9 Fans The server supports five fan modules The fan modules are hot swappable The server tolerates failure of a single fan The fan speed can be adjusted The same model of fan modules must be used in a server ...

Страница 46: ...FusionServer 2298 V5 Server Technical White Paper 5 Hardware Description 2022 06 25 46 Figure 5 25 Fan module positions ...

Страница 47: ...ort serial port J13 3 LOM GE port J11 4 TPM TCM port TPM CONN J55 5 VGA connector VGA CONN J112 6 PCIe riser slot PCIE RISER J1 J8 J9 7 10GE optical port J132 8 10GE optical port J131 9 mini SAS HD connector MINIHD PORTA J86 10 USB 3 0 port USB3 0 CONN J169 11 I2 C management network port I2C J10 a 12 USB 3 0 port INNER USB3 0 J173 13 OCP 2 0 mezzanine card slot 14 Right mounting ear connector ...

Страница 48: ...agement cable connector HDD BP CONN0 J7 23 Fan 2 port FAN1 J104 24 Left mounting ear connector LEAR BOARD J167 25 Fan 1 port FAN0 J105 26 Lower drive drawer management cable connector HDD BP CONN1 J162 27 Mainboard power connector PWR IN1 J185 28 Mainboard power connector PWR IN0 J184 29 PSU management connector J182 30 RTC battery CMOS BATTY U4042 31 Onboard PCIe slot J179 32 Onboard PCIe slot J1...

Страница 49: ...ane Front Drawer Drive Backplane Figure 5 27 Front drawer drive backplane BOM 03025YVL 1 Drive connector J20 2 Backplane management signal cable connector J1 3 Slimline connector PORT A 4 Drive identification indicator 5 Indicator signal cable connector J1701 6 Slimline connector PORT B 7 Power connector J2 ...

Страница 50: ...n 2022 06 25 50 Rear Drive Backplane Figure 5 28 Rear drive backplane BOM 03024BPV 1 Power connector REAR BP POWR3 J22 2 mini SAS HD connector Port A J2 3 Slimline A connector SLIMLINE A J8 4 Slimline B connector SLIMLINE B J9 5 Backplane signal cable connector HDD BP J23 ...

Страница 51: ...ne power connector J10 a 3 Backplane power connector J9 4 Backplane power connector J8 5 Mainboard power connector J4 6 PSU signal connector J5 7 Mainboard power connector J3 8 PSU signal connector J16 a 9 Power connector J6 a 10 PSU signal connector J17 11 Mainboard power signal connector J15 12 Backplane power connector J12 a 13 Backplane power connector J14 a a The port is reserved ...

Страница 52: ...sors Intel Xeon Scalable Skylake and Cascade Lake processors Built in memory controller and six memory channels Built in PCIe controller supporting PCIe 3 0 and 48 lanes per processor Two UPI buses between processors providing up to 10 4GT s transmission per channel Up to 28 cores per processor Max 3 8 GHz Min 1 375 MB L3 cache per core Max 205 W TDP NOTE The preceding information is for reference...

Страница 53: ... details see https kb vmware com s article 2003322 The M 2 SSD cannot be used to store data due to poor endurance In write intensive applications the M 2 SSD will wear out in a short time Use enterprise level high endurance HE SSDs or HDDs for data storage The M 2 SSD is not recommended for write intensive service software due to poor endurance Do not use the M 2 SSD as the cache Supports hot swap...

Страница 54: ... to a PoE device may cause link communication failure or even damage the NIC I O expansion 5 PCIe 3 0 slots One slot dedicated for an OCP 2 0 mezzanine card and four for standard PCIe cards For details see 5 7 2 PCIe Slots and 5 7 3 PCIe Slot Description NOTE The preceding information is for reference only Use the Compatibility Checker to obtain specific information Port Supports a variety of port...

Страница 55: ...ith third party management systems Security feature Power on password Administrator password TCM only in China TPM Secure boot 6 2 Environmental Specifications Table 6 2 Environmental specifications Category Specifications Temperature Operating temperature 5 C to 35 C 41 F to 95 F ASHRAE Class A1 A2 compliant Storage temperature within three months 30 C to 60 C 22 F to 140 F Storage temperature wi...

Страница 56: ...netic or corrosive dust in the equipment room NOTE It is recommended that the particulate pollution in the equipment room be monitored by a professional agency Acoustic noise The declared A weighted sound power levels LWAd and declared average bystander position A weighted sound pressure levels LpAm listed are measured at 23 C 73 4 F in accordance with ISO 7779 ECMA 74 and reported in accordance w...

Страница 57: ...imensions H x W x D 86 1 mmx447 mmx890 mm 3 39 in x 17 60 in x 35 04 in Figure 6 1 Physical dimensions NOTE See Figure 6 1 for methods in measuring physical dimensions of the chassis Installation dimension requirements Requirements for cabinet installation Cabinet compliant with the International Electrotechnical Commission IEC 297 standard Cabinet width 482 6 mm 19 in Cabinet depth 1100 mm 43 31 ...

Страница 58: ... drives 24 x 3 5 front drives 4 x 2 5 rear drives 2 x M 2 SSDs Packaging materials 5 kg 11 02 lb Energy consumption The power consumption parameters vary with server configurations including the configurations complying with energy related products ErP requirements Use the Power Calculator to obtain specific information ...

Страница 59: ...ic middleware software and hardware The slight differences of the application software middleware basic software and hardware may cause performance inconsistency between the application layer and test software layer If the customer has requirements on the performance of specific application software contact sales personnel to apply for POC tests in the pre sales phase to determine detailed softwar...

Страница 60: ...ed to perform special tasks such as performing high voltage operations and driving a forklift If this device works in a residential environment the wireless interference may be generated Human Safety Only certified or authorized personnel are allowed to install the device Discontinue any dangerous operations and take protective measures Report anything that could cause personal injury or device da...

Страница 61: ...tches and jewelry Figure 8 2 shows conductive objects that must be removed before you touch a device Figure 8 2 Removing conductive objects Figure 8 3 shows how to wear an ESD wrist strap a Put your hands into the ESD wrist strap b Tighten the strap buckle and ensure that the ESD wrist strap is in contact with your skin c Insert the ground terminal attached to the ESD wrist strap into the jack on ...

Страница 62: ...ipment Safety Use the recommended power cables at all times Use power cables only for dedicated servers Do not use them for other devices Before operating equipment wear ESD clothes and gloves to prevent electrostatic sensitive devices from being damaged by ESD When moving a device hold the bottom of the device Do not hold the handles of the installed modules such as the PSUs fan modules drives an...

Страница 63: ...rried by a Person To reduce the risk of personal injury comply with local regulations with regard to the maximum weight one person is permitted to carry Table 8 1 lists the maximum weight one person is permitted to carry as stipulated by a number of organizations Table 8 1 Maximum weight carried per person Organization Weight kg lb European Committee for Standardization CEN 25 55 13 International ...

Страница 64: ...s and protocols KVM and text console redirection Remote virtual media IPMI SNMP Common information model CIM Redfish Browser based login Specifications Table 9 1 iBMC specifications Specifications Description Management interface Integrates with any standard management system through the following interfaces IPMI CLI HTTPS SNMP Redfish Fault Detection Detects and accurately locates faults in a fie...

Страница 65: ...eproduction Reproduces faults to facilitate fault diagnosis Screen snapshots and videos Allows users to view screenshots and videos without login facilitating routine preventive maintenance inspection PMI Black Box Allows users to enable or disable the black box function and download black box data DNS LDAP Supports domain management and directory services which significantly simplify network and ...

Страница 66: ...A11 2020 CISPR 32 2015 A1 2019 EN IEC 61000 3 2 2019 A1 2021 EN 61000 3 3 2013 A1 2019 EN 55035 2017 A11 2020 CISPR 35 2016 EN 55024 2010 A1 2015 CISPR 24 2010 A1 2015 ETSI EN 300 386 V1 6 1 2012 ETSI EN 300 386 V2 1 1 2016 RoHS EN IEC 63000 2018 ErP Commission Regulation EU 424 2019 UK UKCA Safety EN 62368 1 2014 A11 2017 EMC EN 55032 2015 A11 2020 CISPR 32 2015 A1 2019 EN IEC 61000 3 2 2019 A1 2...

Страница 67: ...5024 2010 A1 2015 CISPR 24 2010 A1 2015 ETSI EN 300 386 V1 6 1 2012 ETSI EN 300 386 V2 1 1 2016 RoHS BS EN IEC 63000 2018 ErP Commission Regulation EU 424 2019 US FCC FCC PART 15 Canada IC ICES 003 China CCC GB 17625 1 2012 GB 4943 1 2011 GB T GB T 9254 1 2021 China RoHS SJ T 11364 GB T 26572 Japan VCCI VCCI 32 1 Global CB IEC 62368 1 2014 ...

Страница 68: ...on are for reference only For details see the actual product A 1 1 On the Front Top Figure A 1 Chassis head label 1 Nameplate 2 Certificate 3 Quick access tag 4 SN NOTE For details see A 2 Product SN 5 Reserved space for custom label 6 Pressure proof label NOTE This label indicates that do not place any objects on top of a rack mounted ...

Страница 69: ...1 1 1 Nameplate Figure A 2 Nameplate example Table A 1 Nameplate description No Description 1 Server Model For details see A 4 Nameplate 2 Device names 3 Power Supply Requirements 4 Vendor Information 5 Authentication ID A 1 1 2 Certificate Figure A 3 Sample certificate of conformity ...

Страница 70: ...escription No Description 1 P fixed 2 Z fixed 3 Y Server B Semi finished product of the whole machine N Loose spare parts 4 0 Reserved bit 5 Year 2 digits 6 Month 1 digit Digits 1 to 9 indicate January to September respectively Letters A to C indicate October to December respectively 7 Day 1 digit Digits 1 to 9 indicate the 1st to 9th Letters A to H indicate the 10th to 17th Letters J to N indicat...

Страница 71: ...turing serial number 5 digits A 1 1 3 Sample Quick Access Tags Figure A 5 Sample quick access tags Table A 4 Quick access tab description No Description 1 IP address of the iBMC management network port 2 Subnet mask of the iBMC management network port 3 Default iBMC user name 4 Default iBMC password 5 Default BIOS password 6 Technical support website 7 P N Code 8 QR Code NOTE Scan the QR code to o...

Страница 72: ... guide is located on the inside of the chassis cover It describes how to remove the mainboard components important components of the chassis precautions and QR codes of technical resources The pictures are for reference only For details see the actual product The quick guide is optional For details see the actual product A 2 Product SN The serial number SN on the slide out label plate uniquely ide...

Страница 73: ...e years 2018 to 2022 respectively Letters P to Y indicate years 2023 to 2032 respectively NOTE The years from 2010 are represented by upper case letters excluding I O and Z because the three letters are similar to the digits 1 0 and 2 The second character indicates the month Digits 1 to 9 indicate January to September respectively Letters A to C indicate October to December respectively 5 Serial n...

Страница 74: ... the memory temperature to prevent the memory from being damaged due to overheat Rank Sparing Uses some memory ranks for backup to prevent the system from breaking down due to uncorrectable errors Memory Address Parity Protection Detects memory command and address errors Memory Demand and Patrol Scrubbing Corrects correctable errors upon detection If these errors are not corrected in a timely mann...

Страница 75: ...ects error information recorded in hardware registers in compliance with UEFI specifications notifies the OS through the APEI interface of the ACPI and locates the error unit improving system availability Error Injection Support Implements fault injection to verify RAS features Machine Check Architecture MCA Provides a software repair function to rectify uncorrectable errors to improve system avai...

Страница 76: ...board N indicates the CPU number The value is 1 or 2 CPUN VRD Temp CPU VRD temperature Mainboard N indicates the CPU number The value is 1 or 2 CPUN MEM Temp CPU DIMM temperature DIMMs of CPUN N indicates the CPU number The value is 1 or 2 SYS 3 3V Mainboard 3 3 V voltage Mainboard SYS 5V Mainboard 5 0 V voltage Mainboard SYS 12V_1 Mainboard 12 0 V voltage Mainboard SYS 12V_2 Mainboard 12 0 V volt...

Страница 77: ...he backplane number The value is 1 or 2 HDD BPN 12V Drive backplane 12 0 V voltage Front drive backplane N indicates the backplane number The value is 1 or 2 CPUN VCCP CPU VCCP voltage Mainboard CPUN DDR VPP1 CPU DDR voltage Mainboard CPUN DDR VPP2 CPU DDR voltage Mainboard FANN Speed Fan speed Fan moduleN N indicates the fan module number The value ranges from 1 to 5 Power Server input power PSUs...

Страница 78: ... module number The value ranges from 1 to 5 DIMMN DIMM status DIMMN N indicates the DIMM slot number RTC Battery RTC battery status An alarm is generated when the voltage is lower than 1 V RTC battery PCIE Status PCIe status PCIe cards ACPI State ACPI status Mainboard Power Button Power button pressed state Mainboard and power button Watchdog2 Watchdog Mainboard Mngmnt Health Management subsystem ...

Страница 79: ...U fan status PSUN N indicates the PSU number The value is 1 or 2 PSN Temp Status PSU presence PSUN N indicates the PSU number The value is 1 or 2 DISKN Drive status DriveN N indicates the drive slot number The value ranges from 0 to 27 M2DiskN Status of the M 2 drives on the riser card M 2 drives on the riser card PortN Link Down LOM LOM PCIe RAID Temp PCIe RAID controller card temperature PCIe RA...

Страница 80: ...Sensor Description Component PS Inlet Temp PSU air inlet temperature PSUs OCP1 OP Temp OCP 2 0 mezzanine card optical module temperature OCP 2 0 mezzanine card optical module temperature OCP1 Temp OCP 2 0 mezzanine card chip temperature OCP 2 0 mezzanine card chip temperature ...

Страница 81: ...Intel and DEC Ethernet uses the Carrier Sense Multiple Access Collision Detection CSMA CD access method and allows data transfer over various cables at 10 Mbit s The Ethernet specification is the basis for the IEEE 802 3 standard B 2 F J G Gigabit Ethernet GE An extension and enhancement of traditional shared media Ethernet standards It is compatible with 10M and 100M Ethernet and complies with IE...

Страница 82: ...system Intel is the main sponsor for PCIe PCIe is used only for internal interconnection A PCI system can be transformed to a PCIe one by modifying the physical layer instead of software PCIe delivers a faster speed and can replace almost all AGP and PCI buses R redundancy A mechanism that allows a backup device to automatically take over services from a faulty device to ensure uninterrupted runni...

Страница 83: ... Glossary 2022 06 25 83 B 5 U Z U U A unit defined in International Electrotechnical Commission IEC 60297 1 to measure the height of a cabinet or chassis 1 U 44 45 mm UltraPath Interconnect UPI A point to point processor interconnect developed by Intel ...

Страница 84: ...rnating current AES Advanced Encryption Standard New Instruction Set ARP Address Resolution Protocol AVX Advanced Vector Extensions B BBU backup battery unit BIOS Basic Input Output System C CD calendar day CE Conformite Europeenne CIM Common Information Model CLI command line interface D DC direct current DCPMM DC persistent memory module ...

Страница 85: ...ss memory DVD digital video disc E ECC error checking and correcting ECMA European Computer Manufacturer Association EDB Execute Disable Bit EN European Efficiency ERP enterprise resource planning ETS European Telecommunication Standards C 2 F J F FB DIMM Fully Buffered DIMM FC Fiber Channel FCC Federal Communications Commission FCoE Fibre Channel over Ethernet FTP File Transfer Protocol G GE Giga...

Страница 86: ...MP Internet Control Message Protocol IDC Internet Data Center IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IGMP Internet Group Message Protocol IOPS input output operations per second IP Internet Protocol IPC intelligent power capability IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface C 3 K O K KVM keyb...

Страница 87: ...Network Controller Sideband Interface C 4 P T P PCIe Peripheral Component Interconnect Express PDU power distribution unit PHY physical layer PMBUS power management bus POK power OK PWM pulse width modulation PXE Preboot Execution Environment Q QPI Quick Path Interconnect R RAID redundant array of independent disks RAS reliability availability and serviceability RDIMM registered dual in line memor...

Страница 88: ... device data correction SERDES serializer deserializer SGMII serial gigabit media independent interface SMI serial management interface SMTP Simple Mail Transfer Protocol SNMP Simple Network Management Protocol SOL serial over LAN SONCAP Standards Organization of Nigeria Conformity Assessment Program SSD solid state drive SSE Streaming SIMD Extensions T TACH tachometer signal TBT Turbo Boost Techn...

Страница 89: ...d dual in line memory module UEFI Unified Extensible Firmware Interface UID unit identification light UL Underwriter Laboratories Inc USB Universal Serial Bus V VCCI Voluntary Control Council for Interference by Information Technology Equipment VGA Video Graphics Array VLAN virtual local area network VRD voltage regulator down W WEEE waste electrical and electronic equipment WSMAN Web Service Mana...

Отзывы: