Indicator
Description
PSU indicator
⚫
Off: No power is supplied.
⚫
Blinking green at 1 Hz:
−
The input is normal, and the server is standby.
−
The input is overvoltage or undervoltage.
−
The PSU is in deep hibernation mode.
⚫
Blinking green at 4 Hz: The firmware is being upgraded
online.
⚫
Steady green: The power input and output are normal.
⚫
Steady orange: The input is normal, but no power output is
supplied.
NOTE
The possible causes of no power output are as follows:
⚫
Power supply overtemperature protection
⚫
Power output overcurrent or short-circuit
⚫
Output overvoltage
⚫
Short-circuit protection
⚫
Device failure (excluding failure of all devices)
UID Indicator
The UID indicator helps identify and locate a device.
⚫
Off: The device is not being located.
⚫
Blinking or steady blue: The device is being located.
NOTE
You can control the UID indicator state by pressing the UID button or
running a command on the iBMC CLI.
Connection status
indicator of the
management network
port
⚫
Off: The network port is not connected.
⚫
Steady green: The network port is properly connected.
Data transmission status
indicator of the
management network
port
⚫
Off: No data is being transmitted.
⚫
Blinking yellow: Data is being transmitted.