3-3
Check point
Procedure
Pass/Fail
FELCOM 15
NCS common chan-
nel is synchronized
1) Turn on the power.
2) Confirm that “SYNC” appears at the bottom of the
screen.
Position is correctly
input
Confirm that position data appears at the lower right
corner and is correct.
Equipment state
Confirm the equipment state on the System Status
Monitor
Initialize floppy disk
Insert disk in drive, and press
F1
,
8
and
Enter
(twice)
to initialize disk.
Prepare a message,
save it to a floppy
disk as file and open
the file
1) Press
F1
,
1
. Prepare message.
2) Press
F1
,
4
, and key in file name and press the
Enter to save the file.
3) Press
F1
,
2
, and select file.
4) Press the
Enter
to open the file.
Test
Press the
F7
,
6
and
3
.
Check Distress Alert
Unit IC-305 for
proper operation.
1. Press the
F7
,
6
,
4
and
Enter
in order. The dis-
tress Alert Button Test mode screen appears.
2. Open the cover on
DISTREESS
button.
3. Press the
DISTRESS
button.
4. Confirm that the IC-305 sounds the audible
alarm.
5. Close the cover on the
DISTRESS
button.
6. Press any key to escape.
Note:
FELCOM 15 cannot receive distress alert during
test mode.
Содержание RC-1800F2 Series
Страница 20: ...1 10 This page is intentionally left blank...
Страница 36: ...3 6 This page is intentionally left blank...
Страница 44: ...10 Jun 08 R Esumi D 1...
Страница 45: ...July 14 03 D 2...
Страница 46: ...Dec 20 02 D 3...
Страница 47: ...Apr 17 07 R Esumi D 4...
Страница 48: ...D 5...