1. HOW TO INSTALL THE EQUIPMENT
2
Determining the mounting location
After choosing the approximate mounting location to a table or bulkhead, ensure that the location
is suitable to supply power to the unit.
1.
Connect the power cable to the unit.
If the sensor unit is connected last to the optional Junction Box FI-5002, cut off the connector
(supplied) of the cable M12-05BM+05BF-060 from the FI-5002 side, and connect the red wire
of the cable to the positive terminal (+) of the battery (12 VDC) and the black wire to the neg-
ative terminal (-).
If you connect PG-700 directly to the instrument, or to a network, each device must be tem-
porarily connected to each other, and a power supply 12 VDC (see page 6).
2.
Place the unit at the intended mounting position and supply power. Verify that the STATUS
lamp is not lit red.
If the STATUS lamp illuminates red, there may be a problem with the internal magnetic sen-
sor.
3.
Press and hold the [+] and [-] keys simultaneously for seven seconds, and release both keys.
The CHECK lamp blinks, and the CALIB and STATUS lamps turn off.
Ship's Switchboard
Battery
12 VDC
Red Black
CALIB
STATUS CHECK
THIS SIDE UP
BOW
PG-700
Flashing (green)