background image

1

1.

INSTALLATION

1.1

Equipment Lists

Standard supply

Optional supply

* : Not compatible with Bottom Discrimination Display and ACCU-FISH

 features. 

Name

Type

Code No.

Qty

Remarks

Network Fish Finder

DFF1-UHD

-

1

Spare Parts

SP02-05601

001-033-740

1 set

Fuse (2 pcs.)

Installation Materials CP02-08500

000-011-917

1 set

- Power cable assy. (3.5 m)
- LAN cable assy. (5 m)
- Self-tapping screws

Name

Type

Code No.

Remarks

Transducer

B265LH

000-022-521

1 kW, bronze housing, thru hull

B275LH-W*

000-027-419

1 kW, bronze housing, thru hull, wide beam

CM265LH

000-022-531

1 kW, plastic housing, tank mount

CM275LH-W*

000-027-408

1 kW, plastic housing, tank mount, wide beam

Thru-hull pipe

TFB-7000

000-022-532

Tank

T-711

000-022-539

Cable Assembly

MOD-Z072-020+

001-167-880-10 2 m, for HUB-101

Cable Assembly

MOD-Z072-100+

001-167-900-10 10 m, for HUB-101

Speed/Tem-
perature Sensor

ST-02MSB

001-164-150-10 Thru-hull mount, steel hull

ST-02PSB

001-164-160-10 Thru-hull mount, plastic hull

Temperature 
Sensor

T-04MSB

000-026-893

Thru-hull mount

T-04MTB

000-026-894

Transom mount

Rectifier

PR-62

000-013-484

100 VAC

000-013-485

110 VAC

000-013-486

220 VAC

000-013-487

230 VAC

Connector Kit for 
TX Sync

OP02-86

001-205-780

Содержание NXT-600

Страница 1: ...NETWORK FISH FINDER DFF1 UHD OPERATOR S MANUAL www furuno com Model ...

Страница 2: ......

Страница 3: ... or service marks of their re spective holders How to discard this product Discard this product according to local regulations for the disposal of industrial waste For disposal in the USA see the homepage of the Electronics Industries Alliance http www eiae org for the correct method of disposal How to discard a used battery Some FURUNO products have a battery ies To see if your product has a batt...

Страница 4: ...Only qualified personnel can work inside the equipment Do not disassemble or modify the equipment Fire electrical shock or serious injury can result Turn off the power immediately if the equipment is emitting smoke or fire Fire or electrical shock can result if the power is left on Turn off the power immediately if water leaks into the equipment or an object is dropped inside the equipment Continu...

Страница 5: ...not work inside the equipment unless qualified to do so Electricla shock can occur Turn off the power before beginning the installation Fire or electrical shock can result if the power is left on Be sure no water leaks at the mounting location for the transducer and temp erature sensor Water leakage can sink the vessel Also confirm that neither the transducer nor the sensor will loosen by vibratio...

Страница 6: ...5 2 2 1 How to prepare the cables 5 2 2 2 How to connect the transducer cable 7 2 2 3 How to connect the cable for the external KP 9 2 3 LAN Cable 11 3 INITIAL SETTINGS 13 3 1 DIP Switch Setting 13 3 2 Operation Check 14 4 MAINTENANCE 15 4 1 Maintenance 15 4 2 How to Replace the Fuse 16 4 3 How to Restore Default Settings 16 APPENDIX 1 JIS CABLE GUIDE AP 1 APPENDIX 2 INSTALLATION OF TRANSDUCERS AP...

Страница 7: ...ssing a target Noise suppressing display for enhanced detection performance Fish size shown for depths up to 200 m and bottom discrimination Echoes are shown in high ultra definition thus echoes are displayed differently from those present ed on the conventional fish finder The interference rejector operates differently from the interference rejector on the conventional fish finder thus its effect...

Страница 8: ... 50 60 Hz NETWORK FISH FINDER DFF1 UHD 12 24 VDC Transducer Rectifier PR 62 Speed Temperature Sensor ST 02MSB ST 02PSB Temperature Sensor T 04MSB T 04MTB NavNet Equipment TZT9 14 BB B265LH B275LH W CM265LH CM275LH W Ethernet HUB HUB 101 External KP ...

Страница 9: ...nze housing thru hull wide beam CM265LH 000 022 531 1 kW plastic housing tank mount CM275LH W 000 027 408 1 kW plastic housing tank mount wide beam Thru hull pipe TFB 7000 000 022 532 Tank T 711 000 022 539 Cable Assembly MOD Z072 020 001 167 880 10 2 m for HUB 101 Cable Assembly MOD Z072 100 001 167 900 10 10 m for HUB 101 Speed Tem perature Sensor ST 02MSB 001 164 150 10 Thru hull mount steel hu...

Страница 10: ...ilated Mount the unit where shock and vibration are minimal Keep the unit away from electromagnetic field generating equipment such as motors and gen erators Leave slack in cables for maintenance and servicing ease A magnetic compass may receive interference from the network fish finder if it is placed too close to the network fish finder Observe the compass safe distances noted in the safety inst...

Страница 11: ...ar However the sensor must not be located where it may be damaged in dry docking operations Select a place apart from equipment generating heat Select a place in the forward direction viewing from the drain hole to allow for circulation of cool ing water Select a place free from vibration Do not install near the transducer of an echo sounder to prevent interference to the echo sounder 1 4 2 Mounti...

Страница 12: ...to the sounder picture Make the length of the wire as short as possible For FRP vessels install a ground plate that mea sures approx 20 cm by 30 cm on the outside of the hull bot tom and connect the ground wire there White Black Ground wire IV 2 sq DFF1 UHD MOD Z072 050 5 m option 2 10 m TZT9 TZT14 TZTBB GROUND MJ A3SPF0013 035C 3 5 m External KP Temperature or Speed Temperature Sensor Transducer ...

Страница 13: ... transducer cable can be removed if it interferes with treatment of the cable How to prepare the transducer cable CM265LH CM275LH W B265LH B275LH W Name Type Code No Qty Remarks Upset UI Screw B M4u20 000 163 756 10 2 Super Gland MGB20M 12B 000 177 248 10 1 PH Connector Assembly 02 1097 4P 001 206 000 1 Cable Clamping Plate 02 167 1528 100 379 090 10 1 Rainproof Panel 02 167 1529 100 379 100 1 No ...

Страница 14: ...5 to each core 2 Remove the armor 210 mm and cut off the vinyl sheath 90 mm 3 Remove 5 mm of the vinyl sheath from the cores then connect each crimp on lug attached at step 2 as shown below 4 Wrap the armor with vinyl tape b Approx 10 mm a Approx 100 mm c d Fold back core Armor MPYC 4 Approx 210 mm Vinyl sheath Approx 90 mm Approx 5 mm This part is fixed with the lock nut inside the unit This part...

Страница 15: ...e cover grasp the cover at two sides spread the cover slightly and lift 2 Loosen four screws to remove the shield cover 3 Detach the two WAGO connectors TB3 TB4 inside the equipment 4 Unfasten the sealing nut from the super gland for the transducer cable WAGO connector opener WAGO connectors TB4 TB3 Sealing nut Super gland ...

Страница 16: ...low and the interconnection diagram 8 Reattach the WAGO connectors to the circuit board 9 Fasten the clamp fixing plate referring to the table below for how to orient the plate Transducer model Clamp fixing plate orientation CM265LH CM275LH W Projection on plate upward B265LH B275LH W Projection on plate downward Loosen two screws to unfasten cable clamping plate for transducer cable 1 Twist condu...

Страница 17: ...n for the external KP 3 Do the following 1 Unfasten the sealing nut and lock nut from the supplied super gland As shown below pass the cable through the sealing nut super gland hole in the network fish finder and the lock nut 2 Prepare the cable end referring to How to prepare the cable for the external KP on page 6 Transducer Clearance between super gland and sealing nut Torque CM265LH CM275LH W ...

Страница 18: ...ble 7 Pass the cable through the edge saddle shown below then connect the cable to J12 on the PWRTX board Be sure the cable does not contact TB4 Note For cable MPYC 2 tape the vinyl sheath of the cable approx 6 to 7 turns where it lies in the cable clamp and fasten the cable clamp The PH connector has two unused harnesses Cut them at their base or wrap them with vinyl tape 4 mm Clamp fixing plate ...

Страница 19: ... 020 MOD Z072 100 1 Unfasten the sealing nut from the LAN connector then remove the sealing insert and clamping claw 2 Detach the sealing insert from the clamping claw as shown below EMI core EMI core 10 mm 10 mm Super gland Super gland How to detach clamping claw Hold the clamping claw seal assy as shown left with the teeth of the clamping claw toward you Push in the sealing insert with your thum...

Страница 20: ...sert and clamping claw into the sealing nut then tighten the nut 5 Tighten the sealing nut to fasten the LAN cable The clearance between the sealing nut and the super gland shall be 3 mm The torque for the sealing nut is 1 8 2 0 Nm How to disconnect the LAN cable Loosen the two screws on the gland to access the cable s connector A lock washer is fitted to the gland so the screws cannot be unfasten...

Страница 21: ...N Use IP address assigned by DHCP 2 IP address no OFF Set the 1 switch to OFF to set IP address See the table on the next page for IP address assignment 3 Restore default settings other than LAN and transducer See section 4 3 4 Restore ALL default settings See section 4 3 5 6 Keep these switches in the OFF position 7 TD ID output ON OFF OFF Output TD ID ON Don t output TD ID Turn ON for NavNet 3D ...

Страница 22: ... The LED on the cover of the DFF1 UHD lights or blinks according to equipment state as described in the table below LED state and meaning 2 Host name IP address OFF ES092002 172 031 092 002 ON ES092003 172 031 092 003 LED state Meaning Lit continuously Standby state If no signal is received via LAN for more than 10 minutes the equipment automatically goes into standby to lessen power consumption P...

Страница 23: ...rrect problem Once a month Cleaning the network fish finder s cabinet Dust or dirt on the cabinet may be removed with a dry cloth Do not use chemical based cleaners to clean the cabinet they can remove markings and damage the cabinet Once a month Transducer Marine life on the transducer face will result in a gradual decrease in sensitivity Check the trans ducer face for cleanliness each time the b...

Страница 24: ...e all default settings or restore those other than transducer and LAN This procedure should only be performed by a suitably qualified FURUNO technician 1 Disconnect the power and LAN cables from the DFF1 UHD 2 Open the outer cover and shield cover Turn on the 3 or 4 switch of DIP Switch S3 as ap plicable 3 Restore default settings other than LAN and transducer 4 Restore all default settings Use th...

Страница 25: ...YCY 4 0 75mm2 1 11mm 17 7mm TTYCY 4S 0 75mm2 1 11mm 21 1mm TTYCY 4SLA 0 75mm2 1 11mm 19 5mm TTYCYS 1 0 75mm2 1 11mm 12 1mm TTYCYS 4 0 75mm2 1 11mm 18 5mm TTYCYSLA 1 0 75mm2 1 11mm 11 2mm TTYCYSLA 4 0 75mm2 1 11mm 17 9mm EX TTYCYSLA 4 MPYC 4 Designation type of twisted pairs Designation type of cores 1 2 3 4 5 6 1 2 3 4 Cables listed in the manual are usually shown as Japanese Industrial Standard J...

Страница 26: ...ransducer recommended for fiberglass or wood hull only Stainless steel transducer compatible with all hull materials Recommended for aluminum hulls to prevent electrolytic corrosion provided the stainless steel transducer is isolated from the metal hull Identify Your Model The model name is printed on the cable tag Tools Materials Safety goggles Dust mask Electric drill Drill bits and hole saws m ...

Страница 27: ... an accessible spot inside the vessel with adequate space for the height of the stem and tightening the nut CHIRP transducer Mount in a cool well ventilated area away from the engine to avoid overheating Installation No Fairing or Standard Fairing Only IMPORTANT If installing the transducer with NO fairing disregard all references to a fairing and backing block Hole Drilling Cored fiberglass hull ...

Страница 28: ...n to squeeze out excess sealant Take care to align the transducer with the blunt button arrow end facing forward toward the bow The long side must be parallel to the centerline of the boat see Figure 4 Stainless steel transducer in a metal hull Be sure the isolation sleeve is between the transducer stem and the hull see Figure 2 However the isolation sleeve must be below the hull nut to prevent th...

Страница 29: ...gap between the cylinder and hull with casting epoxy After the epoxy has set remove the cylinder 6 Sand and clean the area around the hole inside and outside to ensure that the sealant will adhere properly to the hull If there is any petroleum residue inside the hull remove it with either mild household detergent or a weak solvent alcohol before sanding 7 Proceed with Cutting the Standard Fairing ...

Страница 30: ...sipate heat Airmar s CHIRP transducers have been designed to be installed in specific ways according to the number and placement of these heat sinks External Thru Hull Mount Models B265 LH LM B275LH W B765 LH LM R109 LH LM R109LH W R509 LH LM R509LH W Transducer is installed entirely outside of the hull A stem or stuffing tube hole is drilled through the hull for the transducer cable The active fa...

Страница 31: ...there is any petroleum residue inside the hull remove it with either mild household detergent or a weak solvent alcohol before sanding Record the information found on the cable tag for future reference Part No _________________Date___________ Follow the precautions below for optimal product performance and to reduce the risk of property damage personal injury and or death WARNING Always wear safet...

Страница 32: ... interference separate the transducer cable from other electrical wiring and the engine Coil any excess cable and secure it in place with cable ties to prevent damage 2 Refer to the instrument owner s manual to connect the transducer to the instrument Installation in a Cored Fiberglass Hull The core wood or foam must be cut and sealed carefully The core must be protected from water seepage and the...

Страница 33: ... ketones can attack many plastics possibly damaging the sensor Reapply anti fouling paint every 6 months or at the beginning of each boating season Replacement Sensor Parts The information needed to order a replacement sensor is printed on the cable tag Do not remove this tag When ordering specify the part number and date For convenient reference record this information at the top of page one Lost...

Страница 34: ...below for optimal product performance and to reduce the risk of property damage personal injury and or death WARNING Always wear safety goggles and a dust mask when installing WARNING Below the waterline mount When the boat is placed in the water immediately check for leaks around the screws and any other holes drilled in the hull CAUTION Installation on a metal hull The stainless steel housing mu...

Страница 35: ... pencil 8 Using a 3mm or 1 8 drill bit drill a pilot hole s at the marked locations 10mm 3 8 deep 9 Apply marine sealant to the threads of the screw s to prevent water from seeping into the transom 10 Fasten the cable clamp s in place 11 If a hole has been drilled through the transom apply marine sealant to the space around the cable leading through the transom Cable Routing Connecting 1 Route the...

Страница 36: ...33 5 2727 10 1622 40 471 100 215 200 112 500 68 1200 31 2 INTERFACE 2 1 I O port Network 1 port Temp speed sensor 1 port External KP 1 port external KP kit option 2 2 Network method Ethernet 10Base T 100Base TX 3 POWER SUPPLY 3 1 Network fish finder 12 24 VDC 2 8 1 4 A 3 2 Rectifier PR 62 option 100 110 220 230 VAC 1 phase 50 60 Hz 4 ENVIRONMENTAL CONDITIONS 4 1 Ambient temperature 15 C to 55 C 4 ...

Страница 37: ... 7 06 ขᛒ ᦠ 12 4 614 5 07 1 䍘㪄䍢䍼 ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍ 䍘䍎䍢䍼䉕 䈚䉁䈜䇯 㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅 䋨 䈱ኸᴺ䈲䇮ෳ ୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 ဳᑼ㪆䍘䍎䍢䍼 ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍 Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏 䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ 䈲ᄌ䉒䉍䉁䈞䉖䇯 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 A 1 A...

Страница 38: ...26 Aug 2014 H MAKI D 1 ...

Страница 39: ...2 52 2 8 Ǿ 016 5 2 4 5722 126 10 ᵈ 㧖㧝㧕ㅧ ᚲᚻ ޕ 㧖㧞㧕ࠝࡊࠪ ࡦ ޕ 6 6 0 6914 5 0 4 2 6 6 A A2 A A A 1A A 1A2 0 A 1A5 A A5 0 64 A 0A2 64 A 0A0 64 A176A2 64 A176A0 5 6 2A A 0 6 2 2 176 2 0 7 9 6 7 9 6 14 40 9 6 ࠕࠝ ࠢࡠ 㩂㩥 㩆㩥 㨻㨿 㩆㩥 ࠗ ࡖ ࠪࡠ 4 0 4 0 4 0 8 US ㅍฃᵄེ 64 05 7 4 2 6 2 O 2 2 0 ࡀ ࡢ ࠢ㝼ត 0 6914 5 0 4 7 ㅦ ࡦࠨ 6 2 52 5 0514 ࡦࠨ 6 2 5 0514 56 5 25 O O 6 5 6 6 9 9 GE GE 㧖㧟㧕 ߅ࠃ 9ߩߺ ޕ 14 0 9 S 1 2 Dec 2014 H MAKI 2 ...

Страница 40: ...ufficient Otherwise the invoice with serial number name and stamp of the dealer and date of purchase is shown For the Onboard Warranty your FURUNO certified dealer will take care of all registrations 5 Warranty Claims For the Standard Warranty simply send the defective product together with the invoice to a FURUNO national distributor For the Onboard Warranty contact a FURUNO national distributor ...

Страница 41: ...c or its authorized dealer at the time of request for warranty service This warranty is valid for installation of products manufactured by Furuno Electric Co hereafter FURUNO Any purchases from brick and mortar or web based resellers that are imported into other countries by anyone other than a FURUNO certified dealer agent or subsidiary may not comply with local standards FURUNO strongly recommen...

Страница 42: ...1 2008 IEC 60945 Ed 3 0 1996 clauses 10 2 and 10 3 title and or number and date of issue of the standard s or other normative document s For assessment see Test Report FLI 12 12 121 January 19 2013 prepared by Furuno Labotech International Co Ltd This declaration is issued according to the Directive 2014 30 EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation o...

Страница 43: ......

Страница 44: ...r Printed in Japan Elemental Chlorine Free The paper used in this manual is elemental chlorine free 9 52 Ashihara cho Nishinomiya 662 8580 JAPAN All rights reserved Pub No OME 20400 E5 MISU DFF1 UHD A JAN 2013 E5 JUN 14 2017 䢲䢲䢲䢳䢹䢹䢴䢶䢷䢳䢶 ...

Отзывы: