background image

 

 

5

5.  Grease the two hex head bolts for fastening the display unit to the mounting base 

(lower). 

6.  Fasten the display unit to the mounting base (lower) with the two hex head bolts 

greased at step 5. 

Hex Head Bolt

 

Fastening the mounting base (lower) to the display unit 

7.  For portrait orientation, attach logo (supplied) at upper left hand corner. 
 

Содержание MU-150C

Страница 1: ...MULTI PURPOSE LCD DISPLAY MU 150C ...

Страница 2: ......

Страница 3: ...iar with electrical circuits and service manual Improper handling can result in electrical shock Turn off the power at the switchboard before beginning the installation Fire or electrical shock can result if the power is left on Do not install the equipment where it may get wet from rain or water splash Water in the equipment can result in fire electrical shock or damage to the equip ment Safety I...

Страница 4: ...ment 7 3 ADJUSTMENTS 10 3 1 Picture Adjustment 11 3 2 RGB Adjustment 12 3 3 Brilliance Adjustment 12 4 OPERATION 13 5 MAINTENANCE TROUBLESHOOTING 14 5 1 Maintenance 14 5 2 Troubleshooting 15 APPENDIX Modification for Switching from Landscape to Portrait Orientation AP 1 SPECIFICATIONS SP 1 PACKING LISTS OUTLINE DRAWINGS INTERCONNECTION DIAGRAM ...

Страница 5: ...ne can perform its intended function unless properly installed and maintained Please carefully read and follow the operation installation and maintenance procedures set forth in this manual We would appreciate feedback from you the end user about whether we are achieving our purposes Thank you for considering and purchasing FURUNO Features Main or remote display for radars video sounders sonars Co...

Страница 6: ...utput to the MU 150C instead of the interface unit NMEA 0183 RGB Connectable equipment MU 150C Display Unit Type Equipment Landscape Portrait FR 1500 MK3 series Yes No FCV 1200 series Yes Yes Modification required FCV 1500 series No Yes Modification required GD GP 280 380 680 Yes No CH 250 Yes No CH 37 No Yes Modification required CSH 23 73 83 No Yes FR 1760DS No Yes Modification required Display ...

Страница 7: ...or AC CP10 04901 Installation Materials CP10 04920 001 414 700 1 set For DC CP10 04902 FP10 02501 001 414 490 1 set Accessories FP10 05401 001 402 540 1 For FCV 1500L Bracket FP10 02510 001 414 510 1 Including FP10 02511 Option Name Type Code No Qty Remarks Bracket FP10 02510 001 414 510 1 Including FP10 02511 Hood Landscape FP10 02502 001 414 730 1 Hood Portrait FP10 02503 001 414 750 1 See packi...

Страница 8: ... maintenance See the outline drawing for recommended servicing space The unit weighs 35 3 lbs 16 kg Be sure the mounting location is strong enough to support the weight of the unit Locate the unit away from areas subject to water splash and rain Flush mounting See the outline drawing at the end of the manual for mounting dimensions CAUTION Hold the cover and display unit together when lifting the ...

Страница 9: ... diameter M5 although the size of the mounting holes in the display unit is M8 384 0 5 366 1 15 0 5 333 0 5 315 1 259 0 5 45 82 100 384 0 5 366 1 15 0 5 333 0 5 315 1 259 0 5 45 82 100 Mounting dimensions for landscape orientation Mounting dimensions for portrait orientation Unit mm Unit mm Mounting dimensions 4 Reattach the cover 5 For the portrait model only attach the FURUNO logo seal supplied ...

Страница 10: ... washers and nuts FRONT Hex Head Bolt Spring Washer Flat Washer Nut Mounting base lower 2 Fasten the bracket and mounting plate to the mounting base upper with 12 hex head bolts Fasten the mounting plate at the rear for 9 tilt or at the front for 20 tilt Hanger Mounting Plate Mounting Base upper REAR FRONT Hanger Mounting Plate Mounting Base upper 9 degree TILT 20 degree TILT Fastening bracket and...

Страница 11: ...ower cable local supply in case of AC power cable from the control and operation sections of external equipment and ground wire local supply at the rear of the MU 150C For use of the cable type 06S4078 from a control section cut off the connector s rubber cover and remove the fixing metal to enable connection NMEA Cable from operation section MJ A10SPF0002 Cable from control section 06S4078 5m Pow...

Страница 12: ...to the mounting base lower 6 Fasten the display unit to the mounting base lower with the two hex head bolts greased at step 5 Hex Head Bolt Fastening the mounting base lower to the display unit 7 For portrait orientation attach logo supplied at upper left hand corner ...

Страница 13: ...tach it to the display unit with Velcro tape as shown below 1 Attach nine sets of Velcro tape to the display unit at the locations shown below in as straight as possible Attach in line Attach in line Display unit how to attach Velcro tapes 2 Attach the hood to the display unit ...

Страница 14: ...ut through the D SUB 25P connector 24 VDC or 100 240 VAC Ground Terminal Mini D SUB 15P CH 37 DISPLAY CH 250 INTERFACE UNIT RGB OUT FCV 1200 Series INTERFACE UNIT RGB OUT FCV 1500 Series DISPLAY UNIT DISPLAY GP GD 280 380 680 DISPLAY UNIT EXT VIDEO FR 1500 MK3 Series Connector on RGB BUFFER board in display unit FR 1760DS Connector on RGB BUFFER board in display unit Display unit rear view wiring ...

Страница 15: ...cables Notes on wiring For AC specification solder connector SRCN6A13 3S supplied in installation materials to the power cable DPYC 1 5 Japan Industrial Standard or equivalent Sectional view of cable DPYC 1 5 Armor Conductor S 1 5 mm2 f 1 56 mm Armor 2 1 3 Connector Housing Screw Clamp Tighten set screw Connect to 1 and 2 Solder Side Armor 4 6 cm Sheath 3mm Armor Soldering connector SRCN6A13 3S 1 ...

Страница 16: ...of waterproof construction however the MU 150C is not waterproof specification IPX0 Therefore remove rubber cover and fixing metal from the display side of the cable Remove rubber cover Remove fixing metal D sub connector ...

Страница 17: ...he rear of the display unit Open the small cover to access the controls CONT NMEA DATA VIDEO IN 2A POWER 100 240 VAC 50 60 Hz 1 2 3 GND S1 S2 S3 S4 J16 J17 J18 R1 R2 R3 J16 J17 J18 R1 R2 R3 EXTBRILL BRILL BRTP R G B S1 S2 S3 S4 SEL UP DOWN RESET 1 31 31 3 Rear panel AC type ...

Страница 18: ...ast Center horizontal position for landscape type vertical position for portrait type Center vertical position for landscape type horizontal position for portrait type Geometry S1 Press S4 to Initialize settings About the picture adjustment buttons The S2 and S3 buttons may be pressed and held down to increase decrease setting more rapidly The S4 button can initialize settings individually or all ...

Страница 19: ... Adjustment Brilliance can be adjusted from the control unit of the FCV 1200 series or CH 250 by setting jumper block J17 as below J17 Brilliance control circuit selection 1 2 Brilliance is adjusted from the MU 150C default setting 2 3 Brilliance is adjusted from the control unit of the FCV 1200 series or CH 250 Note Do not change the setting of the J16 or J18 The default setting for both is 1 2 S...

Страница 20: ...ch as the FCV 1200 series turn on the POWER switch of the MU 150C Note that with the MU 150C turned on and the FCV 1200 turned off the LED on the MU 150C lights in red This means that weak current is flowing to the MU 150C To turn off the power completely turn off the MU 150C BRILLIANCE control Adjusts display brilliance In some instances brilliance is controlled from the equipment connected for e...

Страница 21: ... cloth Do not use chemical cleaners to clean any part of the display unit they can remove paint and markings Wipe the LCD carefully o prevent scratching using tissue paper and an LCD cleaner To remove dirt or salt deposits use an LCD cleaner wiping slowly with tissue paper so as to dissolve the dirt or salt Change paper frequently so the salt or dirt will not scratch the LCD Do not use solvents su...

Страница 22: ...t to check inside the equipment there are no user serviceable parts inside Refer any work to a qualified technician Troubleshooting table Reason for no picture Remedy Battery voltage too high Check battery voltage Fuse has blown Replace fuse Cable between MU 150C and external equipment has loosened Refasten cable Power cable has loosened Refasten cable ...

Страница 23: ... LCD side down It is recommended to place the unit on cushioning material so as not to place pressure on knob 2 Unfasten the items marked with white arrows in the figure below to remove the cover for the power section and connectors 10 screws four spacers for connectors and two nuts of waterproof connectors This gives access to the CONE Board 10P6877 and power assy Display unit rear view 3 Remove ...

Страница 24: ...onnect the connector and four power switch tag terminals and release cable from CK clamp Note When disconnecting the tag terminals pull them by the metal part of the terminal Do not disconnect by pulling the cable cables may become separated from the terminal Power assy ...

Страница 25: ...fastened at step 5 Torque 0 39 0 04 Nm 4 0 4 kgm 9 Turn the power chassis 180 counterclockwise making sure no load is placed on the cable at the center of the power chassis when turning When reassembling the display unit to landscape turn the power chassis 180 clockwise The tape for fixing the cable from the LCD may peel off if the power chassis is turned twice or more in the same direction 10 Fas...

Страница 26: ...e cover for the power section and connectors with 10 screws M3 x 8 14 Fix four spacers for connectors Torque 0 39 0 04 Nm 4 0 4 kgm 15 Temporarily fasten the cover for the power section and connectors with six screws M3 x 8 Torque 0 78 0 08 Nm 8 0 8 kgm 16 Fasten two waterproofing nuts Torque 0 76 0 02 Nm 7 8 0 2 kgm 17 Fasten the cover near the power section and connectors with remaining four scr...

Страница 27: ...24 x 768 1 4 Viewing Angle 160 left right 80 up down 80 1 5 Input Signal RGB 0 7 Vp p to 3 0 Vp p Synchronization TTL level 2 POWER SUPPLY 2 1 Rated Voltage 100 240 VAC 0 7 0 4 A 1 phase 50 60 Hz 24 VDC 1 4 A 3 ENVIRONMENTAL CONDITION 3 1 Ambient Temperature Operation 0 C to 50 C Storage 20 C to 60 C 3 2 Relative Humidity 95 at 40 C 3 3 Waterproofing IPX0 3 4 Vibration IEC 60945 4 COATING COLOR 4 ...

Страница 28: ...This page is intentionally left blank ...

Страница 29: ...FP10 02501 FP10 02501 FP10 02501 FP10 02501 ロゴシート LOGO SEAL 10 075 1052 0 100 294 900 1 工事材料 工事材料 工事材料 工事材料 INSTALLATION MATERIALS INSTALLATION MATERIALS INSTALLATION MATERIALS INSTALLATION MATERIALS CP10 04902 CP10 04902 CP10 04902 CP10 04902 ケーブル組品MJ CABLE ASSY MJ A3SPF0020 050Z 000 145 882 1 その他工材 その他工材 その他工材 その他工材 OTHER INSTALLATION MATERIALS OTHER INSTALLATION MATERIALS OTHER INSTALLATION M...

Страница 30: ...IES FP10 02501 FP10 02501 FP10 02501 FP10 02501 ロゴシート LOGO SEAL 10 075 1052 0 100 294 900 1 工事材料 工事材料 工事材料 工事材料 INSTALLATION MATERIALS INSTALLATION MATERIALS INSTALLATION MATERIALS INSTALLATION MATERIALS CP10 04901 CP10 04901 CP10 04901 CP10 04901 コネクタ SRCN CONNECTOR SRCN6A13 3S 000 508 665 1 その他工材 その他工材 その他工材 その他工材 OTHER INSTALLATION MATERIALS OTHER INSTALLATION MATERIALS OTHER INSTALLATION MATE...

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ......

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ...0798 65 4200 FIRST EDITION FIRST EDITION JAN JAN 2002 2002 Printed in Japan Printed in Japan All rights reserved All rights reserved C3 C3 OCT OCT 04 2004 04 2004 Pub No Pub No OME 20250 OME 20250 00080923101 00080923101 00080923101 00080923101 YOTA YOTA MU 150C MU 150C 0 0 0 8 0 9 2 3 1 0 1 0 0 0 8 0 9 2 3 1 0 1 OME20250C30 OME20250C30 OME20250C30 OME20250C30 O M E 2 0 2 5 0 C 3 0 O M E 2 0 2 5 0...

Отзывы: