4

0.5A

J12

J11

JP802

CR10

14P0285

JP702

JP602

JP502

JP402

JP902

J10

J8

J7

J6

J5

J4

J9

J3

J2

J1

Power

10-35V

FUSE

JP801

JP701

JP601

JP501

JP901

JP401

S1

CR9

CR8

CR7

CR6

CR4

CR3

CR2

Alarm output 3

Alarm output 2

Alarm output 1

Output port 5

Output port 4

Output port 3

Output port 2

Output port 1

Output port 6

Input port 2

Input port 1

Jumper 

A: IEC61162-1
B: Current loop

B
A

B
A

B
A

B
A

A
B

B
A

A
B

B
A

B
A

B
A

B
A

B
A

 

Parts location 

 

 

Alarm output 1 

Arrival Alarm 

Alarm output 2 

Cross Track Error Alarm

Alarm output 3 

Receiving Error Alarm 

 

Alarm output normal closed type 

Normal 

Relay contact is closed.

Abnormal 

Relay contact is open. 

Turns the power 
off 

Relay contact is open. 

 

LEDs (Normal status) 

CR6 

Blinks every second. 

CR7 Off. 

CR8 Off. 

CR9 

Lights when Input port 1 has 
priority. 

CR10 

Lights when Input port 2 has 
priority. 

Содержание INTERFACE UNIT IF-2500

Страница 1: ...INTERFACE UNIT IF 2500 TENI 0307 PUB No OMC 43421 A1 IF 2500...

Страница 2: ...t away from air conditioner vents Keep the equipment out of direct sunlight Vibration should be minimal The location should be free of water spray CAUTION Observe the following compass safe distances...

Страница 3: ...S Overview 1 Installation materials 1 Spare parts 1 Cables 2 Mounting 2 Grounding 2 Selection of output data format 2 Cable fabrication 2 Maintenance 5 SPECIFICATIONS PACKING LIST OUTLINE DRAWING INTE...

Страница 4: ...nce with priority order Output data is converted to NMEA current loop IEC 61162 1 or contact signal and output Outputs data in accordance with priority order Input 1 GPS navigator Input 2 GPS navigato...

Страница 5: ...utput data format The output data format is selectable by changing a jumper block A for IEC61162 1 and B for NMEA For example to select NMEA for J4 change the jumper block from A to B on JP401 and JP4...

Страница 6: ...h cable Heat shrink tube Heat shrink tube Cut unused cores and solder them to shield Twist and solder Supplied 28 mm 15 mm 15 mm 30 mm 35 mm 75 mm Sheath Armor 3 mm 3 mm Fix the cable with the cable c...

Страница 7: ...Input port 2 Input port 1 Jumper A IEC61162 1 B Current loop B A B A B A B A A B B A A B B A B A B A B A B A Parts location Alarm output 1 Arrival Alarm Alarm output 2 Cross Track Error Alarm Alarm ou...

Страница 8: ...data to J4 thru J9 CR6 Blinks every second CR7 Lights when ROM error is detected CR8 Lights when RAM error is detected CR9 Lights when SIO error is detected CR10 Normally off 5 Remove the connector f...

Страница 9: ...vailable to distribute three outputs from two independent inputs 1 Port Input 2 ports IEC61162 1 Output 6 ports IEC61162 1 or Current loop Alarm signal Output 3 ports Relay contact 2 Alarm signal Rece...

Страница 10: ......

Страница 11: ...ASSY MJ A6SPF0012 100 64S4071 000 133 817 1 TAPPING SCREW 4X16 SUS304 1 000 802 080 4 XH XH CONNECTOR ASSY XH6P 002 000 000 991 2 1 XH XH CONNECTOR ASSY XH5P 002 000 000 992 1 1 XH XH CONNECTOR ASSY...

Страница 12: ...x2P OR P CURRENT LOOP OUTPUT IEC61162 1 J7 XH4P J8 XH4P NC 1 2 3 TD H TD B TD C TD A CO 0 2x2P OR P CURRENT LOOP OUTPUT IEC61162 1 1 2 3 CO 0 2x2P OR P GND 4 5 NC J9 XH5P J10 XH3P ALARM OUTPUT ARRIVAL...