Furuno INTERFACE UNIT IF-2500 Скачать руководство пользователя страница 5

 

 

 

2

Mounting 

This unit does not have power switch. If you 
do not connect the IF-2500 to power 
switchboard or circuit breaker, install an 
external power switch (local supply), locating 
it near the IF-2500. 

 All dimensions in millimeters.

 For added support, use nuts, bolts and 

washers instead of woodscrews.

 Leave sufficient space at the sides and rear 

of the unit for maintenance and servicing.

 

 

Grounding 

To prevent mutual interface, run a ground 
wire between the earth terminal on the unit 
and ship’s superstructure. 
 

Selection of output data format 

The output data format is selectable by 
changing a jumper block; A for IEC61162-1 
and B for NMEA. For example, to select 
NMEA for J4, change the jumper block from A 
to B on JP401 and JP402. Do the same on J5 
thru J9. 
 

Factory setting 

Output

Jumper 

IEC61162-1 

(A) 

Current 

loop 

(B) 

J4 JP401/JP402

 

J5 JP501/JP502

 

J6 JP601/JP602

 

J7 JP701/JP702

 

J8 JP801/JP802

 

J9 JP901/JP902

 

!

 

 

Cable fabrication 

Use the following cables (Japan Industrial 
Standard cables) or the equivalents. 
 

Conductor
S = 0.75 mm

φ

 = 1.11 mm

2

TTYCS-1 (Twisted pair cable)

Conductor
S = 0.2 mm

φ

 = 0.6 mm

2

CO-SPEVV-SB-C 0.2x2P

Armor

Armor

Vinyl sheath

Shield

Shield

Sheath

Sheath

Current loop or IEC 61162-1 signal

Current loop or IEC 61162-1 signal

φ 

10.1 mm

φ 

10.5 mm

 

Содержание INTERFACE UNIT IF-2500

Страница 1: ...INTERFACE UNIT IF 2500 TENI 0307 PUB No OMC 43421 A1 IF 2500...

Страница 2: ...t away from air conditioner vents Keep the equipment out of direct sunlight Vibration should be minimal The location should be free of water spray CAUTION Observe the following compass safe distances...

Страница 3: ...S Overview 1 Installation materials 1 Spare parts 1 Cables 2 Mounting 2 Grounding 2 Selection of output data format 2 Cable fabrication 2 Maintenance 5 SPECIFICATIONS PACKING LIST OUTLINE DRAWING INTE...

Страница 4: ...nce with priority order Output data is converted to NMEA current loop IEC 61162 1 or contact signal and output Outputs data in accordance with priority order Input 1 GPS navigator Input 2 GPS navigato...

Страница 5: ...utput data format The output data format is selectable by changing a jumper block A for IEC61162 1 and B for NMEA For example to select NMEA for J4 change the jumper block from A to B on JP401 and JP4...

Страница 6: ...h cable Heat shrink tube Heat shrink tube Cut unused cores and solder them to shield Twist and solder Supplied 28 mm 15 mm 15 mm 30 mm 35 mm 75 mm Sheath Armor 3 mm 3 mm Fix the cable with the cable c...

Страница 7: ...Input port 2 Input port 1 Jumper A IEC61162 1 B Current loop B A B A B A B A A B B A A B B A B A B A B A B A Parts location Alarm output 1 Arrival Alarm Alarm output 2 Cross Track Error Alarm Alarm ou...

Страница 8: ...data to J4 thru J9 CR6 Blinks every second CR7 Lights when ROM error is detected CR8 Lights when RAM error is detected CR9 Lights when SIO error is detected CR10 Normally off 5 Remove the connector f...

Страница 9: ...vailable to distribute three outputs from two independent inputs 1 Port Input 2 ports IEC61162 1 Output 6 ports IEC61162 1 or Current loop Alarm signal Output 3 ports Relay contact 2 Alarm signal Rece...

Страница 10: ......

Страница 11: ...ASSY MJ A6SPF0012 100 64S4071 000 133 817 1 TAPPING SCREW 4X16 SUS304 1 000 802 080 4 XH XH CONNECTOR ASSY XH6P 002 000 000 991 2 1 XH XH CONNECTOR ASSY XH5P 002 000 000 992 1 1 XH XH CONNECTOR ASSY...

Страница 12: ...x2P OR P CURRENT LOOP OUTPUT IEC61162 1 J7 XH4P J8 XH4P NC 1 2 3 TD H TD B TD C TD A CO 0 2x2P OR P CURRENT LOOP OUTPUT IEC61162 1 1 2 3 CO 0 2x2P OR P GND 4 5 NC J9 XH5P J10 XH3P ALARM OUTPUT ARRIVAL...

Отзывы: