5. Precautions When Using FX Mode

When using FX mode, the operational function restrictions shown in the table below apply.

Function

LAN ports other than FX 

mode port

FX mode LAN port

TEL

Includes the following:

• Access code
• Call filter
• 1st/2nd ring
• Internal call routing
• Group  call
• Automatic switching
• Incoming indicator 

buzzer

Operational

FX mode LAN port is 
reserved for FX mode. 

A handset may be connect-
ed, but will not function.

FAX

Operational

Not usable

UDI/RDI

Operational

Not usable

SMS

Operational

Operational from WEB 
menu. 

Not usable from handset.

PS

WAN

Not usable.

NSD controls PS. 

All non-NSD packet switch-
ing is not available. WEB 
menu for items listed to the 
left are not available.

Not usable.

NSD controls PS. 

All non-NSD packet switch-
ing is not available. WEB 
menu for items listed to the 
left are not available.

PPPoE
Bridge
Remote Access
Multi voice
Multi number

LAN

DHCP

Operational

Not usable

Routing

Operational

Not usable

RIP

Operational

Not usable

VRRP

Operational

Not usable

Alive monitoring

Not usable.

NSD controls PS. 

Alive monitor does cannot 
respond.

Not usable.

NSD controls PS. 

Alive monitor does cannot 
respond.

Syslog transfer

Operational

Not usable

Address book transfer Operational

Not usable

WEB menu

Operational.

PS settings cannot be 
changed, all other settings 
can be changed.

Operational.

WEB menu can be accessed 
via the FX mode LAN port

OTHERS Self-test

Operational

Operational

Содержание INMARSAT FLEET BROADBAND FELCOM 250

Страница 1: ...the FX Service Network The FELOM250 FELCOM500 units function as a backup communication device when using the FX service If the signal from the GX terminal is dropped during transmission the line is au...

Страница 2: ...the LAN port to which the NSD is to be connected then left click 6 At the IP address line set the IP address for the LAN port selected at step 5 7 At the Subnet mask line set the subnet mask for the...

Страница 3: ...s Data Connection FX is added to the end of the indication Data size Shows the data size for the connected PC s group packets Connection This indication normally shown directly below Data size is hidd...

Страница 4: ...acket switch ing is not available WEB menu for items listed to the left are not available Not usable NSD controls PS All non NSD packet switch ing is not available WEB menu for items listed to the lef...

Страница 5: ...filter 1st 2nd ring Internal call routing Group call FX LAN FAX UDI RDI SMS WEB WAN NSD WEB NSD WEB PPPoE Bridge Remote access Multi voice Multi number LAN DHCP Routing RIP VRRP Alive monitoring NSD...

Страница 6: ...3 12 FX mode A Main B Status monitor Communication status Data Connection FX Data size Connection Data size C Main D Data connection Data connection FX mode Label FX FX...

Страница 7: ...5 Port for NSD NSD FX LAN 6 IP address FX LAN IP 7 Subnet mask FX LAN 8 Default route NSD LAN IP 9 Apply The CmmUnt will restart automatically after this settings Continue 10 OK Completed 11 OK Ver09...

Страница 8: ...FELCOM250 500 00019274210 FELCOM250 FELCOM500 FX FELCOM250 500 FX 1 FX FX Fleet Xpress Inmarsat Ka FX GX FX FELCOM250 500 FBB GX 2 FX FELCOM250 500 GX FX FBB FX GX GX FELCOM250 500 Network Service De...

Отзывы: