3. ADJUSTMENTS
7
13. Push the [+] or [-] button to select desired output interval, referring to the table below.
14. Push the [Enter] button. The output interval LED stops flashing.
15. Set up Port 3 similar to how you did Port 2.
16. Close the inner and outer covers.
Sentence
number
Sentence
Output interval (ms)
4800 bps
9600 bps
19200 bps
38400 bps
1
HDT
100, 200,
1000, 2000
25, 100, 200, 1000, 2000
2
HDG
100, 200, 1000, 2000
25, 100, 200, 1000, 2000
3
HDM
100, 200,
1000, 2000
25, 100, 200, 1000, 2000
4
ATT, HVE
200, 1000,
2000
100, 200, 1000, 2000
25, 100, 200,
1000, 2000
5
VTG, GGA, ZDA
1000, 2000
6
RMC, ZDA
1000, 2000
7
ATT, HVE
200, 1000,
2000
100, 200, 1000, 2000
25, 100, 200,
1000, 2000
GGA, VTG, ZDA
1000(<1000), 2000
1000(<1000), 2000
8
HDT
100, 200,
1000, 2000
25, 100, 200, 1000, 2000
RMC, ZDA
1000(<1000), 2000