Page 18

11/16/01

C. GP36 “Sensor Mode” – 

When the installation requires a DGPS Sensor it is possible to

make a small hardware modification to the GP36 Display to allow a NavNet Display to provide
power to the GP36.  This modification locks the GP36 power switch “On”.
In Sensor Mode, the GP36 Display never needs to be accessed and it can be treated as a
DGPS Sensor only. The GP36 Display should be considered as a “Black Box Sensor”.
-For further information on this modification contact the Furuno Technical Department.

-Furuno USA will modify any GP36 to Sensor Mode “Free of Charge” when any FUSA Dealer
specifies “SENSOR MODE” operation for a GP36 order.  Please provide this request to the
FUSA Camas/Denton Order Service Departments.

NOTE: Please turn the backlighting illumination to the “OFF” position on the Sensor Mode GP36
when the display is hidden away and not viewed.

-The GP36 may also be powered from a breaker in Sensor Mode for added redundancy.

D. SENDING POSITION INFORMATION TO MULTIPLE DISPLAYS

If you have a multiple station system with one BBGPS and you want to transmit the NMEA data
from the first display to all of the other displays in the NavNet network, complete the following
procedure:

Configuration Procedure For The NavNet Display That Is Directly Connected To A BBGPS Or
Other Position Source:

Step 1

 - Press MENU, then press SYSTEM CONFIGURATION, SYSTEM SETUP, PORT SETUP,

OUTPUT THROUGH NETWORK.

Step 2

 - Use the ON/OFF soft key and the up down arrows to select which sentences will be

sent out through the network.

Turn on ONLY the
following Strings:
GGA, VTG & ZDA
Do not turn on strings
that are not needed.
The other strings may
be utilized in the
future.

Network

Содержание GD-1700C

Страница 1: ...n Section 2 The Three NavNet Cabling Options CAT5 RJ45 Information Section 3 NavNet Ethernet Hubs and Hub Power Supply Section 4 Easy 4 Step Software Installation Setting Procedures Section 5 Network...

Страница 2: ...twork Components Any NavNet Display GPS Sensors Network Sounder BBFF1 Heading Sensors Smart Temp Depth Sensors RD30 Displays Any NavNet Radar Plotter or Plotter may be used independently as a stand al...

Страница 3: ...the Furuno 6 Pin to 6 Pin Network Cables listed below is the simplest way to network any two NavNet Network components Please note that the Network Sounder is supplied with a standard 5 Meter Network...

Страница 4: ...th cable from Table 3 1 Page 3 for EACH NavNet Display or Network Sounder Each cable must be routed to a suitable location where the Ethernet Hub will be mounted Note The Ethernet Hub Connection will...

Страница 5: ...f dealer supplied CAT5 Cabling and or connections is NOT guaranteed by Furuno and must be performed by the installer Exact CAT5 Network Installation Methods and Practices are MANDATORY Please see our...

Страница 6: ...ht connection for the RJ45 coupler junctions is the responsibility of the installer CAT5 Cable and RJ45 Connector Information While a complete explanation on installing CAT5 Network Cabling is beyond...

Страница 7: ...Only Be Terminated With an RJ45 Connector NEVER use any other kind of connector or normal terminal strip for CAT5 cables The network will simply not function if this is done 110 Punch Down Blocks are...

Страница 8: ...BROWN NOTE Identifying The Pin Assignment of an RJ45 Connector PIN 1 is at the LEFT when looking at the Flat Side of an RJ45 with the cable entry at the bottom 1 8 TOP FRONT 1 8 PIN 1 1 White w Orang...

Страница 9: ...der of the network will still function Hubs will also protect the network from a Network Component that is placing bad data on the network or has timing problems Hubs also provide excellent feedback f...

Страница 10: ...NMEA In GREEN NMEA Input SMART DEPTH SENSOR or OTHER PIN 5 12VDC RED 12VDC OUTPUT 250mA Maximum Current Out PIN 6 Buzzer Out BLACK Buzzer Output to Relay or Other PIN 7 GROUND SHIELD USE BARE SHIELD...

Страница 11: ...technically any Ethernet 10BASE T or 10 100BASE T Hub is compatible with NavNet Products If you have a stable power source available any hub will work DANGER Do Not Attempt to Source More than 250mA f...

Страница 12: ...nnected in a single network It is important that you confirm each individual radar is operational and adjusted properly before the network connections and settings are made Refer to the RADAR SETUP Se...

Страница 13: ...this number is that the last three digits must be different from any other display in the NavNet network Usually this number only has to be changed if there are identical displays in the network RADAR...

Страница 14: ...the other display s chart card slot 1 Both displays are configured to show the radar picture coming from the PORT RADAR 1 C MAP FURUNO and Navionics Chart information may be distributed through the ne...

Страница 15: ...there are 3 displays and a network sounder Note that the RADAR SOURCE of the GD 1900C may be set to either the 1722C or the M1933C but not both GD 1900C 1722C M1933C DON T ALTER NETWORK SOUNDER SETUP...

Страница 16: ...splay it will then be transmitted throughout the NavNet network via ethernet If you are using a GP 310B BBGPS and it is plugged into port 1 your NAV ports need to be changed from the default configura...

Страница 17: ...ON SOURCE to the ALL Selection WARNING IF SUPPLYING POWER TO AN EXTERNAL NAVIGATOR FROM A NAVNET DISPLAY CURRENT DRAW MUST NOT EXCEED 250MA Refer to both the applicable NavNet installation manual and...

Страница 18: ...e turn the backlighting illumination to the OFF position on the Sensor Mode GP36 when the display is hidden away and not viewed The GP36 may also be powered from a breaker in Sensor Mode for added red...

Страница 19: ...keys Step 2 Move your curser to FURUNO GPS SENSOR then press the edit soft key and select NO with the curser control Step 3 Hit the RETURN soft key three times and then press NAV OPTIONS and NAV SOUR...

Страница 20: ...tly to the DATA1 port on any NavNet display If the DATA1 port is occupied by the GP 310B you can use a Y Adapter Cable AIR 033 407 or a terminal strip to connect the Smart Sensor to any NavNet Display...

Страница 21: ...he proper Temp and Depth Data to other NavNet Displays in the Network Follow the same procedure and turn on MTW and DPT at the NavNet Display that is connected to the Smart Sensor 1 2 3 4 5 6 7 WHITE...

Страница 22: ...urce to DATA1 DATA3 7 Mono Color LCD And 10 CRT NavNet Displays Data4 10 4 Color LCD NavNet Displays 1 TD RS232 WHITE 2 RD RS232 BLUE 3 RD A Input YELLOW 4 RD B Input GREEN 5 12V DC RED 6 Buzzer Out B...

Страница 23: ...and Temperature Sources to ETR in the General Setup Menu NOTE The NavNet Display s Depth and Temperature Alarm Parameters will always utilize the source of digital depth and temperature selected in t...

Страница 24: ...tallation Manual for details When finished configuring the radar settings turn the display off then on again to escape from the INSTALLATION MODE STEP 2 Change Nav Position Source to BBGPS Keystroke S...

Отзывы: