1. RADAR OPERATION
1-23
[PICTURE
MENU]
1 INT REJECT
OFF/1/2/3
2 ECHO STRETCH
OFF/1/2/3
3 ECHO AVERAGE
OFF/1/2/3
4 NOISE REJ
OFF/ON
5 AUTO STC
OFF/ON
6 AUTO RAIN
OFF/1/2/3/4
7 VIDEO CONTRAST
1/2/3/4/
A/B/C
8 [PULSE]
9 [CONDITION]
0 DEFAULT (ENTERX3)
1.15 Choosing the Pulselength
The pulselength in use is displayed at the upper-left position of the screen using
the indications shown in the table below.
Label and pulselength
Indication Pulselength
(
μ
s)
S1 (Short pulse 1)
0.07
S2 (Short pulse 2)
0.15
M1 (Medium pulse 1)
0.3
M2 (Medium pulse 2)
0.5
M3 (Medium pulse 3)
0.7
L (Long pulse)
1.2
*: S, M1, M2 and L on FAR-2157(-BB) and S-band radars.
Appropriate pulselengths are preset to individual range scales and function keys.
If you are not satisfied with the current pulselength settings, you may change
them as shown below.
1.15.1 Choosing
pulselength
You can choose the pulselength for the 0.5 to 24 nm range scales as below.
1. Roll the trackball to choose the PICTURE box at the left side of the screen.
Note:
The PICTURE box sets up the radar picture according to expected
usage, such as harbor navigation, long range, short range, etc. For
further details see paragraph 1.33.
2. Push the right button to show the PICTURE menu.
PICTURE menu
Содержание FAR-21 7-BB Series
Страница 1: ...www furuno co jp MARINE RADAR ARPA FAR 28x7 Series FAR 21x7 BB Series Back...
Страница 22: ...SYSTEM CONFIGURATION xx This page intentionally left blank...
Страница 194: ...4 AIS OPERATION 4 24 This page intentionally left blank...
Страница 234: ...5 VIDEO PLOTTER OPERATION 5 40 This page intentionally left blank...
Страница 248: ...6 MAINTENANCE TROUBLESHOOTING 6 14 This page intentionally left blank...
Страница 301: ......
Страница 302: ......
Страница 303: ......
Страница 304: ......
Страница 305: ......