2. WIRING
2-6
2.3.2
How to connect the FA-1701 transponder unit
Referring to the figure and table below, connect the FA-1701. The figure below also
shows the recommended entry point for connected cables. (Based on a vessel con-
figured to use all WAGO connection points.)
The WAGO connection points are individually marked on the TRX-PWR PC board.
Cable entry #8 should be used for DISP cabling, regardless of vessel configuration,
as the entry hole is larger than the other entry points.
Cable entry #2 should be used for LAN connection, regardless of vessel configuration,
to avoid excess stress on the LAN cable.
Note 1:
The cable entry points (for the top row only) are protected from foreign mate-
rial with small plastic spacers. Remove the spacers as required when connecting ca-
bles to the FA-1701.
All cables should be secured at the cable clamps (indicated as #1 through #15 in the
figure above) using cable ties (included). The LAN cable in particular should be se-
cured with the outer sheath of the LAN cable on the cable clamp.
Port
Description
COM1 to
COM3
Long range communication device (Inmarsat C, etc.) or External display
(Radar, ECDIS, NavNet 2, NavNet 3D), BEACON or Pilot Plug Unit
COM4 to
COM6
Long range communication device (Inmarsat C, etc.) or External display
(Radar, ECDIS, NavNet 2, NavNet 3D), Pilot Plug Unit, BEACON or
Sensor (GPS, Gyrocompass, Speed log, ROT)
DISPLAY
Connects to Monitor Unit FA-1702.
ALARM
Connects to on-board alarm system.
BS (Blue
Sign)
Connects a Blue Sign device, a lighting device mounted on the bridge
which gives off a blue light to warn oncoming vessels when the vessel is
navigating a channel in the reverse direction.
SENSOR
GPS, Gyrocompass, Speed log, ROT.
COM1 to COM6
COM1 to COM6
ALARM
BS
SILENT
ALARM
BS
SILENT
SENSOR
SENSOR
DISPLAY
DISPLAY
LAN
LAN
DC (+)
DC (+)
Top row
Top row
Bottom row
Bottom row
DC (-)
DC (-)
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9 10
10 11
11 12
12 13
13 14
14 15
15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
COM6
LAN
COM5
COM4
COM3
COM2
COM1
DISP
DC_IN
SENSOR1
SENSOR2
SENSOR3
ALARM
BS (Blue Sign)
Silent
No.
Connection point
Содержание FA-170
Страница 30: ...2 WIRING 2 10 This page is intentionally left blank ...
Страница 42: ...3 SETTINGS AND ADJUSTMENTS 3 12 This page is intentionally left blank ...
Страница 63: ...D 1 15 Oct 2015 H MAKI ...
Страница 64: ...D 2 3 Mar 2016 H MAKI ...
Страница 65: ...D 3 3 Mar 2016 H MAKI ...
Страница 66: ...D 4 3 Mar 2016 H MAKI ...
Страница 67: ...D 5 3 Mar 2016 H MAKI ...
Страница 68: ...D 6 20 Oct 2015 H MAKI ...
Страница 69: ...D 7 Jan 9 03 ...
Страница 70: ...D 8 15 Dec 2015 H MAKI ...
Страница 71: ...D 9 15 Dec 2015 H MAKI ...
Страница 72: ...Mar 27 07 R Esumi D 10 ...
Страница 73: ...D 11 Feb 02 05 ...
Страница 74: ...D 12 27 Aug 2015 H MAKI ...
Страница 75: ...15 May 2014 H MAKI D 13 ...