4. INSTALLATION
37
4.10 Adjustments after
Installation
NMEA
1. Press the
MENU/ESC
key to open the
menu.
2.
Use
S
or
T
to choose NMEA under System
menu and press the
ENTER
key.
NMEA menu
NMEA0183
Choose NMEA0183 version of nav equipment
connected to “12-24 VDC/NMEA” port among
Ver 1.5, Ver 2.0 or Ver 3.0.
NMEA Port
The NMEA terminals in the “12-24 VDC/
NMEA” port can function as input ports or
input/output port. Change the setting to "In/In"
when connecting GP-310B/320B and a wind
sensor.
When connecting the GP-320B and a wind
sensor, first turn on "WAAS Setup" and then
select "In/In" as the NMEA Port setting.
In/Out:
Input and Output (default setting)
In/In:
Input only (Available with connection of
the GP-310B/320B and a wind sensor.)
NMEA Output
Set the output data sentences (see the left-
table).
Off:
Outputs the “output data sentences” of
FCV-620/585 only.
On:
Outputs the “output data sentences” of
FCV-620/585 and sentences which are input
from other equipment.
WAAS Setup
Choose how to use the WAAS signal when
connecting with a WAAS receiver, for
example GP-320B. The message types
(WAAS-00 to WAAS-27) are used as WAAS
correction. Choose WAAS-00 to enable
WAAS.
Note:
Currently, WAAS is only available in
North America, and it is in the developmental
stage in Europe and Japan. During the devel-
opmental phase the reliability and availability
of the WAAS signal cannot be guaranteed.
Therefore, any position data should be veri-
fied against other sources to confirm reli-
ability. This function is available only when In/
Out is selected at NMEA Port.
TLL Output
Output the position specified by
MARK
key to
the plotter connected.
Off:
Does not output latitude/longitude.
TLL:
Outputs latitude/longitude.
FURUNO-TLL:
Outputs latitude/longitude,
depth and water temperature. Required
FURUNO-TLL enabled device.
Port Monitor
Port Monitor provides information for the data
sentences input to the 12-24 VDC/NMEA
port.
Press the
ENTER
key to display the latest
data sentence information. To display this
information on the Port 2 screen when two
sensors are connected, set NMEA Port on the
NMEA menu to In/In.
Transducer (FCV-585 only)
Choose transducer type among 600 W, 1 kW
and 50/200-1T on the Sounder menu.
Transducer setting box
600 W:
For 600 W transducer
50/200-1T:
For 1 kW transducer (50B-6, 50B-
6B, 200B-5S or 50/200-1T)
1 kW:
For 1 kW transducer other than those
mentioned above
NMEA
S
/
T
/
W
/
X
: Select
[ENTER] : Enter
[MENU] : Back
NMEA0183 : Ver 2.0
NMEA Port : In/Out
NMEA Output : Off
WAAS Setup : Off
TLL Output : TLL
Port Monitor
Port Monitor
$GPGLL, 4928. 186, N, 00022. 705, E, 00035
2, A*24<0d><0a>
$GPVTG, , , 2.6, M, 1.0, N, 1.9, K*39<0d><0
a>
$GPRMC, 000352, A, 4928.186, N, 00022.70
5, E, 001.0, 000.0, 301006, 2.6, W*6B<0d>
<0a>
Port 1
600W
1kW
50/200-1T