1/25/2016
Page | 16
DGOI-C 64 ASSEMBLY INSTRUCTIONS
C16AK0001, Issue 1
Attach the fibers with Velcro. Route the fiber units following the path shown in Figure 27.
Plug the connectors to the parking holder as shown.
Fig. 27 Fiber units routing
3.8. Pigtail Installation
Install the splice trays as needed (Fig.28)
Fig. 28