background image

INTRODUCTION 

Thank you for purchasing the GE-PON ONU Equipment made by Furukawa Electric Co., Ltd. 

This  instruction  manual  describes  the  basic  operations  of  the  ONU  Equipment.  Read  the  instruction 

manual carefully before operating the equipment for proper use of the unit. Store this manual for later 

reference as needed. 

 

 

 

This instruction manual is subject to change without notice. 

Furukawa Electric Co., Ltd. will not bear any responsibility for operation of the equipment. 

No part of this manual may be copied or transcribed without permission. 

 
 
 
 
 
 
 

This  product  is  information  technology  equipment  that  falls  within  the  category  of  Class  B 

(optical  termination  equipment)  based  on  the  standards  of  the  Voluntary  Control  Council  for 

Interference by Information Technology Equipment (VCCI). This equipment assumes the use in 

the home environment and may cause interference with nearby radios or TVs. Use the equipment 

properly as described in the instruction manual. 

 
 
 
 
 

This  equipment  and  instruction  manual  contains  technologies  related  to  strategic  products

specified in the Foreign Exchange and Trade Control Law. Exportation of this equipment and/or 

instruction manual requires approval in conformity to this law. Destroy the instruction manual 

completely when disposing of it. 

 
 
 
 
 
 

-1- 

330-B1272-AH01 

Содержание FITELwave AG20E (L)

Страница 1: ...INSTRUCTION MANUAL For F TELwave AG1600 Series I ONU EQUIPMENT FITELwave AG20E L FURUKAWA ELECTRIC CO LTD 330 B1272 AH01 ...

Страница 2: ...n This product is information technology equipment that falls within the category of Class B optical termination equipment based on the standards of the Voluntary Control Council for Interference by Information Technology Equipment VCCI This equipment assumes the use in the home environment and may cause interference with nearby radios or TVs Use the equipment properly as described in the instruct...

Страница 3: ...adapter fully to the end of the AC outlet Hold the AC adapter body when disconnecting the adapter from the AC outlet Do not damage or modify the power cable Do not place heavy objects on the power cord Do not heat pull or bend the cable Failure to heed this warning may result in damage to the cable leading to electric shock or fire Disconnect the AC adapter from the AC outlet and contact the deale...

Страница 4: ...re moving the equipment Do not apply excessive force to the optical cables connected to the equipment The optical cables are easily affected by bending or twisting forces Handle with great care Excessive bending or twisting will break the cables Do not expose the power cable to heat sources Do not use benzene thinner or other organic solvents to clean the equipment Observe the regulations and disp...

Страница 5: ...re complete Orange ON Authorization by center station is in process or not complete 1 Red Or ange Blinks Link with center station is being established or not established 1 Red ON OFF Equipment is standing by or erroneous 1 PON LINK Green Blinks In testing equipment Green ON LAN 1 is linked up at 1000 Mbps Green Blinks LAN 1 is sending receiving data at 1000 Mbps LAN 1 1000M OFF LAN 1 is not connec...

Страница 6: ... in the specified positions on the equipment bottom Bottom of stay for vertical Anti slip rubber Bottom of equipment Secure the stay for vertical installation to the equipment if the equipment must be installed vertically Fit the arrow mark on the side of the equipment to that on the vertical installation stay when attaching the vertical installation stay Insert the stay until a click is heard Pul...

Страница 7: ... is heard Connect the LAN cables to the user s terminals such as PCs Bring the user s terminals into the automatic negotiation mode Optical cable anel Rear p To center station AC outlet LAN cable User s terminal equipment LAN cable User s terminal equipment AC adapter Item Description AC adapter Commercial 100 VAC 50 60 Hz power LAN 1 port Fixed 10 100 1000 Mbps or automatic negotiation LAN 2 port...

Страница 8: ... 3 Caution Do not install this equipment in a closed place Leave a space of 20 mm or more around it 7 330 B1272 AH01 ...

Страница 9: ... is a possibility of equipment failure Contact the dealer if the equipment does not recover from the fault or in the event of another malfunction Status Check point POWER lamp does not go on Check that the power plug is connected properly LAN1 or LAN2 lamp does not go on Check that the LAN cable is connected properly Check that the LAN cable in use is category 5e or superior Check that the LAN cab...

Страница 10: ...Use environment Temperature 0 to 40 humidity 30 to 80 No dew condensation Applicable standard Conforms to VCCI Class B 9 330 B1272 AH01 ...

Отзывы: