This detachable tension clamp terminal block accepts wire sizes from 0.08mm
2
to 1.0mm
2
and requires a small flat bladed screwdriver (2.5mm max.) to insert and remove wires.
COM
Common connection for all inputs
0V
Internally connected to power connector 0V pin
24V
Internally connected to power connector 24V pin
Input Default
Use
Programmed Function
*
Input
1
Reset
13
2
Start
14
3
Jig Sensor
15
4
Vent Sensor
16
5
-
17
6
-
18
7
-
19
8
-
20
9
-
21
10
-
22
11
-
23
12 -
24
3
2
COM
1
8
9
5
4
7
6
10
11
12
COM
24V
0V
* Optional
15
14
COM
13
20
21
17
16
19
18
22
23
24
COM
24V
0V
The inputs are user-programmable so the default setting shown
may be changed if required.
* The second connector is not fitted as standard. There is a purchase option for enhanced i/o
that provides an additional 12 inputs and 16 outputs if required.
The opto-coupled inputs can be connected to active high or active low circuits since the
common can be either the positive or negative supply. The 24V DC instrument supply would
typically be used for the input circuits, however any DC supply from 5V to 24V could be
used.
Note that the reset input is fail-safe so that it must be made before instrument can start when
remote control is enabled (I/O Configuration menu). See the input connection method
diagrams in the Interfacing section of this guide.