of the bulb. The pinched center section allows some
leverage for unscrewing of the bulb, and the tape
provides some insulation from the heat.

O P E R A T I O N   C O N ’ T

Digital Voltmeter: The PL-PLUSD’s digital voltmeter
continuously measures incoming AC voltages with
extraordinary accuracy (+/- 1VAC). The meter reads
from 45 to 141 volts in 1-volt steps.

Digital Volt / Current Meter and Meter Switch: The
PL-PLUSDM and PM-8DM True R.M.S. digital volt /
current meter continuously measures incoming AC
voltages with laboratory accuracy (+/- 1VAC). The meter
reads from 45 to 141 volts in 1-volt steps. Additionally,
when their meter switch is set in the current mode, it will
measure the full AC load circulating through either the
PL-PLUSDM, or PM-8DM, (+/- 0.1Amp). Because of the
True RMS circuitry employed, variable AC line distortions
will not affect the accuracy of either measurement.

NOTE: The PL-PLUSD, PL-PLUSDM, and PM-8DM
do not compensate for high or low line voltage. If you
frequently move your rack to different locations, derive
power from generators, use long extension cords, travel
internationally, or are in an area prone to brownouts,
you may benefit from the use of one of Furman’s AC
Line Voltage Regulators.

On/Off Rocker Switch: This 15 amp capacity power
switch is specifically designed to stand up to the
enormous high inrush current demands placed by many
Power Amplifiers. Additionally, the semi-transparent
rocker lights when switched to the “ON” position.

T R O U B L E
S H O O T I N G   G U I D E

Symptom:

No power to the AC outlets.

Possible Cause:

Circuit breaker has tripped due to
excessive load.

Action Needed:

Remove one piece of equipment
from the Metered Six unit, and push
the square re-set tab into the Circuit
breaker bezel.

Symptom:

No power to the AC outlets, even after
the Circuit breaker has been re-set.

Possible Cause:

Protection devices are damaged.

Action Needed:

Factory service.

Retractable Rack Lights/
Bulb Replacement

Dimmer
Control

Digital
Voltmeter

On/Off Rocker
Switch

Retractable Rack Lights/
Bulb Replacement

Digital Volt/
Current Meter

On/Off Rocker Switch

Meter Switch

Meter Switch

5

Содержание PL-PLUS

Страница 1: ...Metered Six Series Owner s Manual ...

Страница 2: ...laboratory quality Digital Voltage and True RMS Current meters Your Metered Six unit provides comprehensive protection from power line related transient voltages and noise while the 20 amp capable PRO units provide additional protection from wiring faults common to remote power theaters convention centers and AC generators The Metered Six s fast acting suppression circuit responds in less than a n...

Страница 3: ...have one installed by a qualified electrician Do not defeat the ground or change polarization of the power plug 5 Route the power cord and other cables so that they are not likely to be walked on tripped over or stressed Pay particular attention to the condition of the cords and cables at the plugs and the point where they exit your Metered Six unit To prevent risk of fire or injury damaged cords ...

Страница 4: ...ese units lamps come supplied with five watt night light bulbs Replacements are available at most hardware stores and may be purchased from Furman Sound service as well B U L B R E P L A C E M E N T Bulbs are easily replaced without removing the unit from the rack Here s How First pull the light tube s all the way out Unscrew the cap on the end of each tube to get access to the bulb Be careful not...

Страница 5: ...age If you frequently move your rack to different locations derive power from generators use long extension cords travel internationally or are in an area prone to brownouts you may benefit from the use of one of Furman s AC Line Voltage Regulators On Off Rocker Switch This 15 amp capacity power switch is specifically designed to stand up to the enormous high inrush current demands placed by many ...

Страница 6: ...tatus LED s to indicate abnormal power conditions Under extreme conditions these units will even keep themselves from turning on if the voltage is below 90VAC or above 140VAC During operation the unit will automatically shut down if the voltage rises above 140 volts O P E R A T I O N Retractable Rack Lights and Dimmer Control The PL PROD and PL PRODM utilize a dimmer control for the two retractabl...

Страница 7: ...ndustry wiring faults for example accidental connection to 220VAC where 120VAC is expected The PL PROD PL PRODM and PM PRODM sense voltages that are so high or low that operation would be impossible and shuts the power down before damage can occur The cutoff voltages are under 90V or over 140V Upon initially applying power to these units the Extreme Voltage indicator LED will be lit if the input v...

Страница 8: ...es with laboratory accuracy 1VAC The meter reads from 45 to 141 volts in 1 volt steps Additionally when their meter switch is set in the current mode it will measure the full AC load circulating through either the PL PRODM or PM PRODM 0 1Amp Because of the True RMS circuitry employed variable AC line distortions will not affect the accuracy of either measurement NOTE The PL PROD PL PRODM and PM PR...

Страница 9: ...afety Information The PL PLUSD PL PLUSDM and PM 8DM are N R T L C listed 9 S P E C I F I C A T I O N S Current rating 20 amps 2400 watts at 120 VAC Input Voltage Range 0 to 250 VAC without damage Meter Accuracy Voltmeter 1VAC Ammeter 0 1 amps Spike Protection Modes Line to Neutral Neutral to Ground Line to Ground Clamping Voltage all modes Initial turn on at 200 volts TVSS rating 400V peak at 500 ...

Страница 10: ...Conditioner Regulator or Surge Suppression product as the sole means of protection against a direct lightning hit The first line of defense against lightning should be a lightning arrestor installed on your building s electrical service entrance If your building does not have one contact your local power company or a contractor to have one installed S E R V I C E Before returning any equipment for...

Страница 11: ... to repairs done by any company or individual other than the Furman factory or one of its Authorized Repair Stations All equipment being returned for repair must have a Return Authorization R A Number To get an R A number please call the Furman Service Department at 707 763 1010 ext 121 between the hours of 8 00 am and 5 00 pm US Pacific Time When returning equipment for repair please use the orig...

Страница 12: ...d Inc 1997 South McDowell Blvd Petaluma California 94954 6919 USA Phone 707 763 1010 Fax 707 763 1310 Web www furmansound com E mail info furmansound com Designed and engineered in the U S A Manufactured in China ...

Отзывы: