- 14 -
mbosv_eng (25.02.2014)
mbosv_eng (25.02.2014)
- 15 -
Ziel IP Adresse
The IP addresses of the remote stations must all be different (also different from the own
IP address).
Port für Audio/NF
The audio port is used for transmission of the audio packets. The used UDP protocol must
be activated in firewalls. All ports must be different from each other.
Port für Signalisierung
The signalling port is used to transmit control telegrams (PTT, Squelch). The used TCP
protocol must be activated in firewalls. All ports must be different from each other.
On system page 3
you can change the
user name
and the
password
. Before this page
opens you are prompted once more to enter the current password.
The system page Info
is used to diagnose the network connections. No settings can be
changed in this page.
Verbindungsstatus
Informations on the connection status are displayed for one radio channel. The desired
channel can be sleceted using the + / - buttons.
Debug und Syslogmeldungen
Here, you can see the 20 most recent syslog messages. These are broadcasted throughout
the ethernet. For diagnosis they can be recorded by a suitable tool (Syslog Server,
Wireshark, TCP-Dump).
The Application Pages
Application page 1
allows to configure the common
parameters of operation
of the Major
BOS V. As well as for the system pages, any configuration changes need to be confirmed
with "Anwenden", in order to have effect.
Codec
The audio codec must be chosen accordingly to that of the remote station. As the FT636
IP Interface uses A-law, this codec has to be used for this kind of remote station.
TX-LED
Here you can define if the transmission LED is lit immediately or after the acknowledgement
of the remote station is received.
RS232 Ausgaben
Here you can define which informations are available via the RS232 interface.
Wiederholzeit Vol +/- Tasten
Defines the duration of pressing the button after which the volume is increased/decreased
once more. This time can be configured for the first as well as for further repetitions
separately.
Headseterkennung
Automatic headset detection can be configured via the button „Schwellwert einstellen“. A
new screen opens that leads through the process.
Ein-/ Ausgänge
For pins that can be used as inputs or outputs, the direction of information can be chosen
here.