EC declaration of conformity

In line with the 

• 

EC directive – Equipment and protective systems intended for use in potentially 
explosive atmospheres 2014/34/EU (ATEX)

We hereby declare that the devices in the FUNKEN Kunststoffanlagen GmbH device series:

FRv 125/D/Ex
FRv 140/D/Ex
FRv 160/D/Ex
FRv 180/D/Ex

FRv 200/D/Ex
FRv 225/D/Ex
FRv 250/D/Ex
FRv 280/D/Ex

FRv 125/R/Ex
FRv 140/R/Ex
FRv 160/R/Ex
FRv 180/R/Ex

FRv 200/R/Ex
FRv 225/R/Ex
FRv 250/R/Ex
FRv 280/R/Ex

Device designation:

II 3G c IIB T3 X 04 ATEX D132

comply with all relevant fundamental safety and health requirements of the EC/EU directive
as separate components within an installation on the basis of their design and construction and in 
the form which we have brought onto the market. They comply with the standards
listed below:

Directive/standard

Title

DIN EN 1127-1:2011-10

Explosive atmospheres – Explosion prevention and protection – Part 1: Basic concepts 

and methodology

DIN EN ISO 80079-36:2016

Part 36: Non-electrical equipment for explosive 

atmospheres – Basic method and requirements

DIN EN ISO 80079-37:2016

Part 37: Non-electrical equipment for explosive atmospheres – Non-electrical type of 

protection constructional safety “c”

DIN EN 14986:2017-04

Design of fans working in potentially explosive atmospheres

DIN EN 13237:2013

Terms and definitions for equipment and protective systems intended for use in poten-

tially explosive atmospheres

This declaration is rendered invalid if any modifications are made to the devices in this device series 
without our agreement.

Device designations:

FRv 125–280

Hennef, 11/03/2019                         Peter Müller, Managing Director

Содержание FRV 125

Страница 1: ...diagrams 7 5 2 Cable connections 7 5 3 Thermal contact PTC thermistor for motor protection 7 5 4 Fluctuating power supply 7 5 5 Speed control via the frequency converter 7 5 6 Connection diagrams 8 6...

Страница 2: ...ineering Industry Associ ation and EU Machinery Directive 2014 34 EU ATEX apply Ensure that no critical gas concentrations are present during repair maintenance and assembly tasks in explosion protec...

Страница 3: ...ring transpor tation Pay attention to the centre of gravity approximately central and the weight see technical data Secure the fan using appropriate slings before transportation Ensure the stability o...

Страница 4: ...red points in the base frame and anchored in the on site foundation If the fan is mounted outside a PE drive protection cover provided by the manufacturer must be attached A flame retardant PP rain co...

Страница 5: ...or articles of loose clothing are sucked in 4 1 Safety inspections Conduct the following tests before commissioning After the fan has been positioned at its intended desti nation rotate the impeller...

Страница 6: ...n be found on the plate on the motor cover and at other locations 5 2 Cable connections Cable routing is determined by local conditions and regula tions The type of cable and wire sizes are specified...

Страница 7: ...reactivation before disconnecting the connecting cable of the drive motor To prevent the fan from being unintentionally reactivated via the control unit set the repair switch to 0 or disconnect and is...

Страница 8: ...aware of contaminated components during cleaning maintenance and repair tasks 7 1 Standstill Standstill or temporary storage of the fan must be avoided If this is not avoidable in certain cases the f...

Страница 9: ...aw it from the repair switch or terminal box Remove the supply air and exhaust system if present Release the frame from the vibration dampers 7 5 Maintenance tasks The FUNKEN radial fan is maintenance...

Страница 10: ...are based on the respective operating conditions and must be specified by the operator Extracting heavily contaminated conveyed media can cause deposits to accrete on the fan impeller and the elastic...

Страница 11: ...ease support centre impeller nozzle and retighten screws Fan rotates and does not convey any air or conveys too little air a Air flow interrupted b Fan rotating in incorrect direction c Non uniform in...

Страница 12: ...law Any form of reproduction editing distribution and any form of exploitation outside that permitted by copyright law requires the written consent of the respective creator or author 9 EMERGENCIES In...

Страница 13: ...rket They comply with the standards listed below Directive standard Title DIN EN ISO 12100 2011 Safety of machinery General principles for design Risk assessment and risk reduc tion DIN EN ISO 5801 20...

Страница 14: ...rm which we have brought onto the market They comply with the standards listed below Directive standard Title DIN EN 1127 1 2011 10 Explosive atmospheres Explosion prevention and protection Part 1 Bas...

Страница 15: ...16 SPACE FOR NOTES 16...

Страница 16: ...17 17...

Страница 17: ...EN 12 2019 FUNKEN Kunststoffanlagen GmbH Meysstrasse 1 53773 Hennef Germany Telephone 49 2242 92 09 0 Fax 49 2242 92 09 11 Email funken funken de www funken de K u n s t s t o f f a n l a g e n...