7.7 Malfunctions

Deviations from normal operating statuses of the fan can 
indicate possible malfunctions and must be checked immedi-
ately by the service team.

CAUTION!

Long-term malfunctions can damage the fan and also cause 
personal injury.

 Before rectifying malfunctions, switch off the 
power supply to the fan and secure it against reac-
tivation.

7.8 Explanation of symbols

Warning. Dangerous 
electrical voltage!

Warning. Explosive 
atmosphere!

Warning. Corrosive 
substances!

Warning. Danger of 
hand injury!

Warning. Danger of 
trapping!

Wear 
gloves!

Warning!

This combination of symbol and keyword indicates 

a possibly dangerous situation that may lead to death or 
serious injury if not avoided.

8 COPYRIGHT

The content and writings published in these operating and 
maintenance instructions are subject to German copyright 
law. Any form of reproduction, editing, distribution and any 
form of exploitation outside that permitted by copyright law 
requires the written consent of the respective creator or 
author. 

9 EMERGENCIES

In emergencies, switch off the main switch or disconnect the 
power plug.

Fire extinguishers of fire classes A, B, C and F must be used 
in case of fire. These fire extinguishers must only be used on 
low-voltage plants (up to 1,000 volts). 
Remain at a safe distance while extinguishing fires.

10 OPERATOR’S 
RESPONSIBILITIES

The operator of the fan procures and employs the materials/
media required for the proper operation of the fan. Correct 
handling of these materials/media and the involved dangers 
are the sole responsibility of the operator. The operator 
must provide hazard warnings and disposal instructions. The 
safety data sheets of material manufacturers and media 
manufacturers must be observed.

11 IDENTIFICATION PLATE

The identification plate is located on the identification plate 
panel or housing wall of the fan.

Содержание FRV 125

Страница 1: ...diagrams 7 5 2 Cable connections 7 5 3 Thermal contact PTC thermistor for motor protection 7 5 4 Fluctuating power supply 7 5 5 Speed control via the frequency converter 7 5 6 Connection diagrams 8 6...

Страница 2: ...ineering Industry Associ ation and EU Machinery Directive 2014 34 EU ATEX apply Ensure that no critical gas concentrations are present during repair maintenance and assembly tasks in explosion protec...

Страница 3: ...ring transpor tation Pay attention to the centre of gravity approximately central and the weight see technical data Secure the fan using appropriate slings before transportation Ensure the stability o...

Страница 4: ...red points in the base frame and anchored in the on site foundation If the fan is mounted outside a PE drive protection cover provided by the manufacturer must be attached A flame retardant PP rain co...

Страница 5: ...or articles of loose clothing are sucked in 4 1 Safety inspections Conduct the following tests before commissioning After the fan has been positioned at its intended desti nation rotate the impeller...

Страница 6: ...n be found on the plate on the motor cover and at other locations 5 2 Cable connections Cable routing is determined by local conditions and regula tions The type of cable and wire sizes are specified...

Страница 7: ...reactivation before disconnecting the connecting cable of the drive motor To prevent the fan from being unintentionally reactivated via the control unit set the repair switch to 0 or disconnect and is...

Страница 8: ...aware of contaminated components during cleaning maintenance and repair tasks 7 1 Standstill Standstill or temporary storage of the fan must be avoided If this is not avoidable in certain cases the f...

Страница 9: ...aw it from the repair switch or terminal box Remove the supply air and exhaust system if present Release the frame from the vibration dampers 7 5 Maintenance tasks The FUNKEN radial fan is maintenance...

Страница 10: ...are based on the respective operating conditions and must be specified by the operator Extracting heavily contaminated conveyed media can cause deposits to accrete on the fan impeller and the elastic...

Страница 11: ...ease support centre impeller nozzle and retighten screws Fan rotates and does not convey any air or conveys too little air a Air flow interrupted b Fan rotating in incorrect direction c Non uniform in...

Страница 12: ...law Any form of reproduction editing distribution and any form of exploitation outside that permitted by copyright law requires the written consent of the respective creator or author 9 EMERGENCIES In...

Страница 13: ...rket They comply with the standards listed below Directive standard Title DIN EN ISO 12100 2011 Safety of machinery General principles for design Risk assessment and risk reduc tion DIN EN ISO 5801 20...

Страница 14: ...rm which we have brought onto the market They comply with the standards listed below Directive standard Title DIN EN 1127 1 2011 10 Explosive atmospheres Explosion prevention and protection Part 1 Bas...

Страница 15: ...16 SPACE FOR NOTES 16...

Страница 16: ...17 17...

Страница 17: ...EN 12 2019 FUNKEN Kunststoffanlagen GmbH Meysstrasse 1 53773 Hennef Germany Telephone 49 2242 92 09 0 Fax 49 2242 92 09 11 Email funken funken de www funken de K u n s t s t o f f a n l a g e n...

Отзывы: