background image

393313   •  08/03/20

Functional Devices, Inc.
101 Commerce Drive
Sharpsville, IN 46068

Toll Free:

  (800)  888-5538   

Office: 

(765)  883-5538                 

Fax: 

(765) 883-7505

Email:

 [email protected]

Website:

 www.functionaldevices.com   

2

26 ft.

32 ft.

26 ft.

0ft

0m

8

10

12

0ft

6

12

18

24

6

12

18

24

SIDE VIEW

DETECTION AREA

TOP VIEW

PIR Optical View Pattern

Ultrasonic Detection Pattern

Major Motion, e.g. body                        Smaller Body Movement

    PIR Detection Range                            PIR Detection Range

    Ultrasonic Detection Range                 Ultrasonic Detection Range

3

1

4

2

1

1

2

2

4

4

3

3

Detection Range 

at 8 ft height

a. Test Mode: 

This mode is used to set the Delayed-OFF Time to 5 seconds for 

test mode.

1.  Ensure Power is On

2.  Remove the cover from the Operation Control Console

defaulted to the OFF position.

4.  To enter Test Mode, move the switch from OFF to ON and then back to OFF. IF 

B3 is already in the ON position, test mode can be entered by just moving it 

back to the OFF position.

b. Notes for Test Mode: 

1.  The Delayed-OFF Time will remain in the 5 second test mode for 15 minutes. It 

the black adjustment knob in the control console and exit test mode.

2.  To manually take the sensor out of the test mode, move switch B3 from OFF to 

ON and back to OFF again.

Infrared Range

Range setting

Full CCW = min.(OFF)

Full CW = max.

Ultrasonic Range

Range setting

Full CCW = min.(OFF)

Full CW = max.

Factory Default

Factory Default

Delayed-OFF time

30sec

5min 10min  20min   30min

Full CCW = min.(5 sec.)
Full CW = max.(30 min.)

Factory Default

Day light Sensor

20 FC

40 FC

80 FC 160 FC 320 FC

Full CCW = Lights stay OFF

Full CW = Lights always turn ON (NO daylight override)

Factory Default

SETTINGS:

(Fig. Operation control console)

All aspects of sensor operation can be adjusted here

a. Ultrasonic Adjustment- 

For maximum range, set fully clockwise (CW). 

If reduced range is required, then turn counterclockwise (CCW) and test 

Detection.

b. Infrared Adjustment- 

For maximum range, set fully clockwise (CW). If 

reduced range is required, then turn counterclockwise (CCW) and test 

c. Delayed-OFF Time Adjustment: 

Each time motion is detected, the 

load remains activated for a pre-set time, which is set by the 

Delayed-OFF Time Adjustment, The fully CCW setting (30 seconds) can 

be used for testing. The fully clockwise setting is 30 Minutes. If motion is 

detected during the ON time, then the load remains activated until the 

full ON time has passed since the latest motion detection.

d. Daylight Sensor Adjustment: 

This level needs to be set in a room 

where natural light is at the desired level for the lighting load to not be 

turned on. The sensor will still see motion (indicated by the red LEDS)

1.  Set the daylight sensor knob to fully counter clockwise (lowest level)

3.  Turn the daylight sensor knob clockwise until the light turns on.

5.  This will be the setting

A

B

will then automatically reset to the Delayed-OFF Time setting as defined by

Отзывы: