8-1
A0CF0TR
TROUBLESHOOTING
Check IC607, D614, D615 and their periphery, and
service it if defective.
The power cannot be turned on.
The fuse blows out.
FLOW CHART NO.1
FLOW CHART NO.2
Is normal state restored when once unplugged power
cord is plugged again after several seconds?
Check if there is any leak or short-circuiting on the
primary circuit component, and service it if defective.
(IC607, Q601, Q602, D609, D610, D611, D612,
T601, T602, R601)
Yes
No
Yes
Is the fuse (F601) normal?
See FLOW CHART No.2 <The fuse blows out.>
No
Yes
Is 32V voltage supplied to the cathode of D514?
No
Check each rectifying circuit of the secondary circuit
and service it if defective.
Check the presence that the primary component is
leaking or shorted and service it if defective.
Check the presence that the rectifying diode or circuit
is shorted in each rectifying circuit of secondary side,
and service it if defective.
After servicing, replace the fuse (F601).
When the output voltage fluctuates.
FLOW CHART NO.3
Does the photocoupler circuit on the secondary side
operate normally?
No
Yes
Check IC607, Q513, D516, D529 and their periphery,
and service it if defective.
When buzz sound can be heard in the vicinity of power circuit.
FLOW CHART NO.4
Check if there is any short-circuit on the rectifying diode and the circuit in each rectifying circuit of the secondary side, and
service it if defective. (D504, D511, D514, D523, D524, D525, D539, D540, Q405, Q501, Q503, Q509, Q510, Q517, Q518, Q521)
Содержание LT850-M32 - SERVICE
Страница 13: ...4 2 A0CF0DC_rev 2 Rear Cabinet 1 Stand Assembly S 4 S 4 S 2 S 3 S 2 S 2 S 2 S 1 S 5 Fig D1...
Страница 36: ...10 4 A0CF0SCP2 Power Supply 2 Schematic Diagram...
Страница 37: ...10 5 A0CF0SCP3 Power Supply 3 Schematic Diagram...
Страница 39: ...10 7 A0CF0SCF Function IR SENSOR Junction Schematic Diagram...
Страница 77: ...LT850 M32 A0CF0EP 2011 05 31 Ver 2...