5-2
A0CN0EA
1. Purity Check Mode
This mode cycles through full-screen displays of red,
green, blue, and white to check for non-active pixels.
1. Enter the Service mode.
2. Each time the [7] button on the remote control unit
is pressed, the display changes as follows.
3. To cancel or to exit from the Purity Check Mode,
press [BACK] button.
2. VCOM Adjustment
1. Operate the unit for more than 20 minutes.
2. Set the color analyzer at the zero point calibration
and bring the optical receptor pointing at the
center of the LCD-Panel at a distance of 3cm away
from the LCD-Panel surface.
3. Enter the Service mode.
4. To enter the “VCOM-2 adjustment mode”, press [3]
button on the remote control unit.
To enter the “VCOM-1 adjustment mode”, press [2]
button on the remote control unit.
5. Press [P
/
] buttons on the remote control
unit so that the color analyzer value becomes
minimum.
6. To cancel or to exit from the VCOM Adjustment,
press [BACK] button.
[7] button
Note:
When entering this mode, the default setting is White mode.
Purity Check Mode
[7] button
Red mode
Green mode
Blue mode
Black mode
[7] button
White mode
[7] button
[7] button
White 20% mode
[7] button
Test Point
Adj. Point
Screen
[P
/
]
buttons
M. EQ.
Spec.
Color analyzer
See below
Figure
Color Analyzer
To avoid interference from ambient
light, this adjustment should be
performed in a dark room.
L = 1.18 inches
Perpendicularity
Содержание LT850-M32 - SERVICE
Страница 13: ...4 2 A0CF0DC_rev 2 Rear Cabinet 1 Stand Assembly S 4 S 4 S 2 S 3 S 2 S 2 S 2 S 1 S 5 Fig D1...
Страница 36: ...10 4 A0CF0SCP2 Power Supply 2 Schematic Diagram...
Страница 37: ...10 5 A0CF0SCP3 Power Supply 3 Schematic Diagram...
Страница 39: ...10 7 A0CF0SCF Function IR SENSOR Junction Schematic Diagram...
Страница 77: ...LT850 M32 A0CF0EP 2011 05 31 Ver 2...