5-2
A0CN0EA
1. Purity Check Mode
This mode cycles through full-screen displays of red,
green, blue, and white to check for non-active pixels.
1. Enter the Service mode.
2. Each time pressing [7] button on the remote
control unit, the display changes as follows.
3. To cancel or to exit from the Purity Check Mode,
press [BACK] button.
2. VCOM Adjustment
1. Operate the unit for more than 20 minutes.
2. Set the color analyzer and bring the optical
receptor to the center on the LCD-Panel surface
after zero point calibration as shown above.
Note:
The optical receptor must be set
perpendicularly to the LCD Panel surface.
3. Enter the Service mode.
4. To enter the “VCOM-2 adjustment mode”, press [3]
button on the remote control unit.
To enter the “VCOM-1 adjustment mode”, press [2]
button on the remote control unit.
5. Press [P
/
] buttons on the remote control
unit so that the color analyzer value becomes
minimum.
6. To cancel or to exit from the VCOM Adjustment,
press [BACK] button.
[7] button
Note:
When entering this mode, the default setting is White mode.
Purity Check Mode
[7] button
Red mode
Green mode
Blue mode
Black mode
[7] button
White mode
[7] button
[7] button
White 20% mode
[7] button
Test Point
Adj. Point
Screen
[P
/
]
buttons
M. EQ.
Spec.
Color analyzer
See below
Figure
Color Analyzer
To avoid interference from ambinent
light, this adjustment should be
performed in a dark room.
L = 3 cm
Perpendicularity
Содержание LT850-M26 - SERVICE
Страница 13: ...4 2 A0CA0DC 2 Rear Cabinet S 1 1 Stand Assembly S 2 S 2 S 3 S 2 S 4 S 2 S 2 S 2 Fig D1...
Страница 35: ...10 4 A0CA0SCP2 Power Supply 2 Schematic Diagram...
Страница 36: ...10 5 A0CA0SCP3 Power Supply 3 Schematic Diagram...
Страница 37: ...10 6 A0CA0INV Inverter Schematic Diagram...
Страница 39: ...10 8 A0CA0SCF Function Schematic Diagram...
Страница 72: ...LT850 M26 A0CA0EP 2010 06 15...