Main CBA Top View
1-8-15
1-8-16
NOTE :
The voltage for parts in hot circuit is measured
using hot GND as a common terminal.
BECAUSE A HOT CHASSIS GROUND IS PRESENT IN THE POWER
SUPPLY CIRCUIT , AN ISOLATION TRANSFORMER MUST BE USED.
ALSO , IN ORDER TO HAVE THE ABILITY TO INCREASE THE INPUT
SLOWLY , WHEN TROUBLESHOOTING THIS TYPE POWER SUPPLY
CIRCUIT , A VARIABLE ISOLATION TRANSFORMER IS REQUIRED.
BHB300F01014-A
BHB300F01014-B
Sensor CBA Top View
BHE470F01014-A
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
CAUTION !
Fixed voltage ( or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F001) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
Содержание 27C-450
Страница 21: ...Main 1 6 Schematic Diagram 1 8 3 1 8 4 HE341SCM1 ...
Страница 22: ...Main 2 6 Sensor Schematic Diagram 1 8 5 1 8 6 HE341SCM2 ...
Страница 23: ...Main 3 6 Schematic Diagram 1 8 7 1 8 8 HE341SCM3 ...
Страница 24: ...Main 4 6 Jack Schematic Diagram 1 8 9 1 8 10 HE341SCM4 ...
Страница 26: ...HE341SCM6 1 8 13 1 8 14 Main 6 6 Schematic Diagram ...
Страница 29: ...1 8 19 1 8 20 Jack CBA Top View Jack CBA Bottom View BHE470F01014 C ...
Страница 52: ...3 1 1 HE240FEX A1X EXPLODED VIEWS Front Panel ...
Страница 54: ...3 1 3 HE341PEX Some Ref Numbers are not in sequence X2 X3 X20 X1 X4 S1 Unit S3 A14 S2 S2 X6 S7 Packing ...
Страница 69: ...27C 450 HE341FD ...