2-3-3
U25PALMA
1-A. Preliminary/Final Checking and
Alignment of Tape Path
Purpose:
To make sure that the tape path is well stabilized.
Symptom of Misalignment:
If the tape path is unstable, the tape will be damaged.
Note:
Do not use an Alignment Tape for this proce-
dure. If the unit is not correctly aligned, the tape may
be damaged.
1. Playback a blank cassette tape and check to see
that the tape runs without creasing at Guide Rollers
[2] and [3], and at points A and B on the lead sur-
face. (Refer to Fig M3 and M4.)
2. If creasing is apparent, align the height of the guide
rollers by turning the top of Guide Rollers [2] and
[3] with a Guide Roller Adj. Screwdriver. (Refer to
Fig. M3 and M5.)
3. Check to see that the tape runs without creasing at
Take-up Guide Post [4] or without snaking between
Guide Roller [3] and AC Head. (Fig. M3 and M5)
4. If creasing or snaking is apparent, adjust the Tilt
Adj. Screw of the AC Head. (Fig. M6)
1-B. X Value Alignment
Purpose:
To align the Horizontal Position of the Audio/Control/
Erase Head.
Symptom of Misalignment:
If the Horizontal Position of the Audio/Control/Erase
Head is not properly aligned, maximum envelope can-
not be obtained at the Neutral position of the Tracking
Control Circuit.
1. Connect the oscilloscope to TP301 (C-PB) and
TP501 (CTL) on the Main CBA. Use TP502 (RF-
SW) as a trigger.
2. Playback the Gray Scale of the Alignment Tape
(FL6N8) and confirm that the PB FM signal is
present.
3. Set the Tracking Control Circuit to the center posi-
tion by pressing CH UP button then “ PLAY ” button
on the unit. (Refer to note on bottom of page
2-3-4.)
4. Use the X-Value Adj. Screwdriver so that the PB
FM signal at TP301 (C-PB) is maximum. (Fig. M6)
5. Press CH UP button on the unit until the CTL wave-
form has shifted by approx. +2msec. Make sure
that the envelope is simply attenuated (shrinks in
height) during this process so that you will know
the envelope has been at its peak.
Guide Roller [2]
Guide Roller [3]
A
B
Take-up Guide Post [4]
AC Head
Fig. M3
Lead Surface of Cylinder
Tape
Fig. M4
Guide Roller
Tape
Correct
Incorrect
Take-up Guide
Post
Tape
Fig. M5
Azimuth Adj. Screw
X-Value Adj.
Screwdriver
Tilt Adj. Screw
AC Head
Fig. M6
Содержание 25A-664
Страница 22: ...1 8 3 1 8 4 1 8 5 HC4S4SCM1 Main 1 5 Schematic Diagram ...
Страница 23: ...1 8 6 1 8 7 1 8 8 HC4S4SCM2 Main 2 5 Schematic Diagram ...
Страница 24: ...1 8 9 1 8 10 1 8 11 HC4S4SCM3 Main 3 5 Schematic Diagram ...
Страница 26: ...Main 5 5 Schematic Diagram 1 8 15 1 8 16 HC4S4SCM5 ...
Страница 27: ...VPS Schematic Diagram 1 8 17 1 8 18 HC4S4SCV ...
Страница 28: ...1 8 19 1 8 20 HC4S4SCF Function Schematic Diagram ...
Страница 29: ...AFV Schematic Diagram 1 8 21 1 8 22 HC4S4SCAFV ...
Страница 30: ...Jack Schematic Diagram 1 8 23 1 8 24 HC4S4SCJ ...
Страница 31: ...1 8 25 1 8 26 Function CBA Top View Function CBA Bottom View BHC400F01018 B ...
Страница 33: ...1 8 29 1 8 30 Jack CBA Top View Jack CBA Bottom View BHC400F01018 E ...
Страница 54: ...2 4 6 U25PALDA S 12 19 Cap Belt Fig DM11 Fig DM12 20 C 1 21 ...
Страница 60: ...3 1 1 HC4C0FEX A1X EXPLODED VIEWS Front Panel ...
Страница 62: ...3 1 3 HC4S4PEX Some Ref Numbers are not in sequence X2 X20C X3 X20B X20A X1 X4 S1 Unit S3 S2 S2 A14 Packing ...
Страница 81: ...25A 664 HC4S4ED ...