Part # FA100 

– HEPA Filter 

The HEPA filter is 99.97% efficient in removing particles as small as 0.3

 from an airstream.   

Particles of this size are respirable and can cause significant respiratory problems.  

 

Replacement: 
A  HEPA’s  service  life  is  determined  by  the  volume  of  sub-micron  particles  remaining  in  the  airstream  after 
passing through the pre-filters.  When properly protected, and depending  on loading, HEPA filters  often provide 

months of service.  

 

Average service life is 2-4 months. 

 
Part # FA201D 

– Gas/Odor Filter 

Most process plumes contain several gases, some odorous 

– some not, some toxic at elevated concentrations – 

some completely harmless regardless of concentration.  To ensure employee safety the type and concentration 

of pollutants must be determined.  Please contact Fumex Engineering for filter selection assistance. These filters 

utilize  a  blended  activated  carbon  and  activated  alumina  impregnated  with  KMnO4  filter  to  capture  and  treat 

gases/odors.  This combination of materials provides protection across a broad range of gases commonly found 

in industrial manufacturing processes. 

 

GENERAL MAINTENANCE 

 
1)  The blower motor(s) is a sealed unit, 24,000 hr. MTBF rated.  It is permanently lubricated and does not require 

oiling 

– keep it free of dust accumulations to prevent overheating. 

2)  Remove any loose accumulations of dust/debris from the air filter chamber periodically. 

 

 
“This product employs overload protection (fuse). A blown fuse indicates an overload or short-circuit situation. If 
the fuse blows, unplug the product from the  receptacle. Replace the fuse as per the user servicing  instructions 

(use only 15-Amp fuse) and check the product. If the replacement fuse blows, a short circuit may be present, and 

the product should be discarded or returned to an authorized 

service facility for examination and/or repair”

 

 

Remote Interface and Connectivity Function 

The  FA2  can  be  supplied  with  an  optional  interface  package  providing  remote  start/stop  and  filter  monitoring 

capabilities  (Part  #  FA227).    Please  see  instructions  below  for  Relay  Activation/De-Activation  procedures  and 

refer to the drawing in Figure 1 for remote connections.  

 
 
 
 
 
 

WARNING 

“To Prevent the Risk of Electrical Shock, Connect Remote Interface 

Cable to 24v, Class 2 Power Supply 

Only” 

 

 

 

 

 

WARNING 

“Disconnect from All Power Supplies Before Servicing” 

Содержание FA2 Series

Страница 1: ...th any solid state speed control device WARNING For general ventilating use only Do not use to exhaust hazardous or explosive materials or vapors WARNING Use only a 15 Amp fuse CAUTION Do not operate without having all filters in place Do not operate any fan with a damaged cord or plug Discard fan or return to an authorized service facility for examination and or repair Do not run cord under carpe...

Страница 2: ...f the cabinet L o c a t i n g t h e a i r c l e a n e r Placing the FA2 as close as possible to the pollution source reduces the amount of ducting needed reduces back pressure lowers power consumption and improves overall performance Placement should minimize hose length and the number of bends Use capture hoods with high efficiency entry whenever possible Make sure to allow top access to the filt...

Страница 3: ...ase in 20 increments until the filter is loaded Red lights will indicate that a filter change is necessary The FA2 contains a VOC sensor to detect odors gases in the exhaust stream The system continually monitors the exhaust stream which is indicated on the bar graph labeled GAS When the gas odor filter becomes saturated and breakthrough of the VOC occurs the GAS warning light will illuminate GENE...

Страница 4: ...d in industrial manufacturing processes GENERAL MAINTENANCE 1 The blower motor s is a sealed unit 24 000 hr MTBF rated It is permanently lubricated and does not require oiling keep it free of dust accumulations to prevent overheating 2 Remove any loose accumulations of dust debris from the air filter chamber periodically This product employs overload protection fuse A blown fuse indicates an overl...

Страница 5: ...ired or replaced at our option free of charge provided it has not been misused abused or otherwise damaged and is returned PREPAID to Fumex LLC 1150 Cobb International Pl Kennesaw GA 30152 There are no warranties which extend beyond the descriptions set forth in this warranty notwithstanding any knowledge of Fumex LLC regarding the use or uses intended to be made of goods proposed changes or addit...

Страница 6: ...e relays have been activated the unit will only start by applying the proper voltage to the start stop relay RELAY DE ACTIVATION PROCEDURES FOR FA2 UNITS 1 To de activate the relays so the remote feature cannot be used the software will need to be reprogramed via a flash drive with a configuration file fumex ini and the USB port on the control board Contact Fumex to acquire the correct configurati...

Страница 7: ...7 Figure 1 ...